Table of Contents Product Manual - VaporMan 125 Manifold Vaporizer System ® Set-up and Dimensions VaporMan 125 Unit ® VaporMan 125 Unit with Carbo-Max 750 Bulk CO System ® VaporMan 125 Unit with Carbo-Max 1000 Bulk CO System ® VaporMan 125 Unit with Perma-Cyl MicroBulk Storage System ®...
VaporMan 125 system and the theory of operation connections The Operations section gives step-by-step procedures for the basic operation of the VaporMan 125 system and the tanks Common Installations involved The Maintenance & Troubleshooting section will become an •...
Preface Product Manual - VaporMan 125 Manifold Vaporizer System ® Terms Acronyms / Abbreviations Throughout this manual safety precautions will be designated The following acronyms / abbreviations are used throughout as follows: this manual: Carbon Dioxide Warning! Description of a condition that...
, cold pipes and equipment, or cold gas exists Safety goggles or a face shield should be worn at all times The VaporMan 125 unit is shipped on a pallet The preferred when connecting to fill connections, while filling the tank handling method is a forklift that lifts the pallet and places and during disconnection from the fill connection.
After using the • Evacuate all personnel immediately from affected areas VaporMan 125 system make sure all of the valves supplying the system are closed Slowly remove the connection • Thoroughly ventilate the area of the spill or leak before...
A separate kit can be bought along with the VaporMan 125 system for two Carbo-Max 1000 tanks There The manifold section provides four connections, a pressure is also a specific part number for a VaporMan 125 system gauge and an economizer regulator The manifold section is Perma-Cyl tank mounted to a panel that is conveniently located for ease of hook up.
Storage System tank there are two optional kits that will need to be purchased as well The kit names are 'KIT CARBOMAX VAPORMAN 1000' and 'KIT VAPORMAN 125 PERMA' Each of these kits includes the hoses and fittings needed in order to use the VaporMan 125 system.
The Gas Use and Economizer Never fill a damaged tank or use a damaged VaporMan 125 sections will change on the Carbo-Max 750 Bulk CO System, and the Gas Use, Economizer, and Pressure Building...
Operations Product Manual - VaporMan 125 Manifold Vaporizer System ® Plumbing Procedures As shown in the following illustrations, you will remove the Economizing sections, Gas Use sections and the Pressure Building sections The parts to be reused are shown on top as...
Product Manual - VaporMan 125 Manifold Vaporizer System Operations ® Carbo-Max 750 Bulk CO System Parts to be Added ® Carbo-Max 750 Bulk CO System Parts to be Removed...
VaporMan 125 Unit System The VaporMan 125 unit is shipped with caps on the four Once the connections are tightened and the entire unit has ports on the manifold If you are using two tanks, you will been leak checked, the VaporMan 125 system can now be...
Replacing the Economizing Miscellaneous Fittings Regulator The remaining pieces on the VaporMan 125 system should be inspected for corrosion or fatigue failure over time All of The regulator used on the manifold is the same type and part the various parts can be provided through...
Specifications Product Manual - VaporMan 125 Manifold Vaporizer System ® VaporMan 125 Unit with Perma-Cyl MicroBulk Storage System ®...
Page 21
Product Manual - VaporMan 125 Manifold Vaporizer System Specifications ® Nomenclature Piping Ref. No. Description Ref. No. Description TOP FILL CHECK VALVE TOP FILL LIQUID VALVE LIQUID WITHDRAWAL GAS USE VALVE PRESSURE BUILDING INLET VENT/FULL TRYCOCK VALVE PRESSURE BUILDING OUTLET PRESS.
Page 22
Specifications Product Manual - VaporMan 125 Manifold Vaporizer System ® Set-up and Dimensions VaporMan 125 Unit ®...
Page 23
Product Manual - VaporMan 125 Manifold Vaporizer System Specifications ® VaporMan 125 Unit with Carbo-Max 750 Bulk CO System ® VaporMan 125 Unit with Carbo-Max 1000 Bulk CO System ®...
Page 24
Specifications Product Manual - VaporMan 125 Manifold Vaporizer System ® VaporMan 125 Unit with Perma-Cyl MicroBulk Storage System ®...
Page 25
Chart, shall in no event exceed the purchase price paid to accident Alterations or repairs by any party other than those Chart by purchaser for the specific equipment or part thereof...
Page 26
New Prague, MN 56071 Authorization must be obtained from Chart prior to shipping any Equipment to Chart facilities In order to process the return of a tank its model and serial number must be provided If approved, a Return Material...