Important: Retain these instructions
These instructions shall be used by trained service
personnel only.
If the equipment is used in a manner not
specified by these instructions, the protection provided by the
equipment may be impaired.
CONTENTS
1
Box Contents .................................................................1
2
Storing ...........................................................................1
3
Installation .....................................................................1
1
BOX CONTENTS
3
INSTALLATION
Labels used on IQXIO
24 Vac AUX
output connector
Supply inputs for
digital outputs
Universal input
connector (UI)
Universal input/
C
output connector
n
(UI/AO)
n
Address switch
Power indicator
DO
1
2
3
4
5
6
1
Dimensions
1
1
X
IO/7
85 mm (3.35")
96 mm (3.78")
IQXIO I/O Expansion Module Installation Instructions TG201447 Issue 1, 24-Mar-2020
IQXIO
Installation Instructions
(TG201447)
I/O Connector (x2)
20 Vdc AUX
output connector
Digital output
n
connector (DO)
Analogue output
override level
0
10V
Hand, off, auto
switch
Status indicator
Output status
AO
2
3
4
5
indicators
17 18 19 20 21 22 23 24 25 26 27 28
0V
B
A
24V
0
1
AUX
DO
AO
2
1
2
1
A
-
O
-
H
X
IO/20
0
10V 0
10V
ADDRESS
1
1
135 mm (5.32")
146 mm (5.75")
Installation Instructions
I/O Expansion Module
GB
DE
DK
IT
NL
NO
https://partners.trendcontrols.com
4
Field Maintenance .........................................................8
5
Disposal .........................................................................8
6
China Hazardous Substance Table ..............................8
2
STORING
-20°C
+65°C
(-4°F)
(+150°F)
Note: For temperatures below 0°C (32°F) special care must be
taken that there is no condensation on or within the unit.
It is recommended that the installation should comply
with the local electrical safety installation practices (e.g.
HSE Memorandum of Guidance on Electricity at Work
Regulations 1989, USA National Electric Code).
Any connected devices must be insulated from mains by
reinforced insulation.
WARNING Removal of cover exposes dangerous
voltages.
WARNING
To reduce the risk of electrical shock or fire
do not interconnect the output of different Class 2 circuits.
29 30 31 32 33 34 35 36
0V
0V
C
C
C
2
3
4
5
10
11
12
13
14
1
2
3
4
5
DO
AO
2
3
4
5
6
1
2
3
4
5
A
-
O
-
H
0
10V 0
10V
0
10V 0
10V 0
10V
2
3
4
5
20V
6
7
8
9
20V
C
C
C
AUX
C
C
AUX
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
IQXIO
ES
FI
FR
PL
SE
RU
95%RH
5
H O
2
60.4 mm
(2.38")
1