heinzinger 72IP User Manual

Power supply interface, digital interface lan option
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 72IP and is the answer not in the manual?

Questions and answers

Summary of Contents for heinzinger 72IP

  • Page 2 Heinzinger electronic GmbH The Power Supply Company Anton-Jakob-Strasse 4 83026 Rosenheim – GERMANY Phone: +49-8031-2458-0 Fax: +49-8031-2458-58 info@heinzinger.de www.heinzinger.com V 1.2 26.09.2012 Heinzinger ® power supplies...
  • Page 3 Betriebsanleitung Digital Interface LAN – V 1.2...
  • Page 4: Table Of Contents

    SCPI-Befehle (Standard Commands for Programmable Instruments) . 8 3.2. Kommunikation über ASCII-Terminal..........8 3.3. Befehlssyntax ................8 3.4. Standardbefehlssatz ..............9 3.5. Sonderbefehlssatz ..............10 3.6. Befehlssatz zur Kalibrierung (anzuwenden nur bei Neuinstallationen)10 3.7. Programmierbeispiel ..............11 Index ....................... 12 Heinzinger ® power supplies...
  • Page 5: Wichtige Grundlegende Informationen

    H a f t u n g , G e w ä h r l e i s t u n g , G a r a n t i e Heinzinger electronic GmbH haftet nicht für Schäden, die aus unsachgemäßer Handhabung der Produkte bzw.
  • Page 6: Was Sie Über Diese Betriebsanleitung Und Das Digitale Interface Wissen Müssen

    B e t r i e b s a n l e i t u n g a l s T e i l d e s G e r ä t s Diese Betriebsanleitung ist nur für Digitale Interfaces IP beim Betrieb in Heinzinger Präzisionsnetzgeräten gültig und muss beachtet werden. Betriebsanleitung beim Gerät verfügbar halten Betriebsanleitung an alle nachfolgenden Anwender weitergeben 1 .
  • Page 7: Technische Daten

    Option 72IP: 12 Bit ≈ 2.5⋅10 von Nennwert Option 76IP: 16 Bit ≈ 1.5⋅10 von Nennwert Isolationsspannung: Digitales Interface 72IP/76IP mit galvanischer Trennung nach Ethernet Standard. Steuerbefehlssatz entsprechend dem SCPI Standard. E T H E R N E T Interface...
  • Page 8: Technische Daten

    Programme für die Serielle Datenübertragung verwendet werden. A C H T U N G Nach dem Programmiervorgang darf die RS232 Schnittstelle nicht mehr genutzt werden, da diese nicht galvanisch getrennt ist und das 1:1 Kabel muss entfernt werden! Heinzinger ® power supplies...
  • Page 9 Danach wird das Interface mit der vorprogrammierten IP – Adresse über ein Crossover - RJ45 Kabel direkt angesprochen und mit der beiliegenden „Sock- Heinzinger“ Software gesteuert! Dies ist eine spezielle Software die ausschließlich über „Heinzinger electronic GmbH“ zu beziehen ist. Für Rücksprachen steht Ihnen gerne unsere Kundenbetreuung zur Verfügung.
  • Page 10: Programmierung

    Befehle werden in Großbuchstaben geschrieben; Kleinbuchstaben sind optional und können weggelassen werden. Jede Befehlssequenz wird mit einem LF-Zeichen (dez. 10) abgeschlossen; nach dem Senden des Befehls vom Rechner (PC) an die Schnittstelle wird dieser sofort ausgeführt. Heinzinger ® power supplies...
  • Page 11: Standardbefehlssatz

    Betriebsanleitung Digital Interface LAN – V 1.2 3 . 4 . S t a n d a r d b e f e h l s s a t z Funktion Befehl Beispiel(e) Programmierung der Soll- VOLTage <Spannungswert> VOLT 500 ausgangsspannung Bei Geräte-U <...
  • Page 12: Sonderbefehlssatz

    DAC- NENN Auflösung] Normiert das Digital- CALibrate:CURRent <I > CAL:CURR 10 NENN Interface zum Bei Geräte- I < 1 A: NENN Gerätenennstrom Gerätenennstrom in mA Bei Geräte- I ≥ 1 A: NENN Gerätenennstrom in A Heinzinger ® power supplies...
  • Page 13: Programmierbeispiel

    Betriebsanleitung Digital Interface LAN – V 1.2 Digitales Interface IP Funktion Befehl Beispiel(e) Liest den gesetzten Strom- CALibrate:CURRent? CAL:CURR? Normierwert aus bezogen auf die DAC- NENN Auflösung] Nur bei integrierter CALibrate:RESistance CAL:RES 50 Option 40: <R > NENN Normiert das Digital- Bei Geräte-R <...
  • Page 14: Index

    Garantie ................ 3 SCPI-Befehle ..............8 Gewährleistung ............. 3 Sonderbefehlssatz ............10 Standardbefehlssatz ............9 Haftung ................. 3 Technische Daten ............5 Ethernet ..............5 Konfiguration Ethernet Schnittstelle ..........6 Zeitverhalten ..............6 Lieferumfang ..............3 Heinzinger ® power supplies...
  • Page 15 User Manual Digital Interface LAN – V 1.2...
  • Page 16 Communication via ASCII-Terminal ..........8 3.3. Command syntax ................ 8 3.4. Standard instruction set ............... 9 3.5. Extra instruction set ..............10 3.6. Calibration instruction set (only for setup purposes) ...... 10 3.7. Sample program ............... 11 Index ....................... 12 Heinzinger ® power supplies...
  • Page 17: Important Basic Information

    L i a b i l i t y , W a r r a n t y Heinzinger electronic GmbH is not liable for damage that results from improper use of the products or due to non-observance of the operating instructions in whole or in part.
  • Page 18: What You Need To Know About This User Manual The Digital Interface

    Interface. Dependant on the type of the power supply only a subset is available for control purposes and/or optional instructions are existing. In particular the technical specifications of the power supply are relevant for the overall system functionality. Heinzinger ® power supplies...
  • Page 19: Technical Specifications

    Option 76IP: 16 Bit ≈ 1.5⋅10 of reference value Insulation voltage: Digital Interface 72IP/76IP with electrical isolation after Ethernet standard. Control command set according to SCPI Standard. E T H E R N E T Interface TCP - with fix IP – address...
  • Page 20: Time Response

    RS232. It is also possible to apply an other programmes for serial data transfer. Caution After programming operation you mustn’t use the Interface RS232 any longer, because it is not electrically isolated and you have to disconnect the serial 1 to 1 cable! Heinzinger ® power supplies...
  • Page 21 User Manual Digital Interface LAN – V 1.2 Afterwards the Interface will be programmed by enclosed “Sock – Heinzinger” software via preset IP – address through a crossover RJ45 Cable! The “Sock-Heinzinger” software is a special software which you can order exclusive by “Heinzinger electronic GmbH”.
  • Page 22: Programming

    [Instruction] [Space] <Parameter optional> [LF] Instructions are written in capital letters; lower case letters are optional. Every instruction sequenz is terminated with a LF (dec. 10); once the instruction is sent to the interface it is executed immediately. Heinzinger ® power supplies...
  • Page 23: Standard Instruction Set

    User Manual Digital Interface LAN – V 1.2 3 . 4 . S t a n d a r d i n s t r u c t i o n s e t Functionality Instruction Sample(s) Programing of Nominal VOLTage <voltage>...
  • Page 24: Extra Instruction Set

    Volt Query of programed scaled CALibrate:VOLTage? CAL:VOLT? voltage value with reference to the DAC- resolution] Scaling of Digital-Interface CALibrate:CURRent <I > CAL:CURR 10 according to the unit If unit-I < 1A: nominal current current declaration milliampere Heinzinger ® power supplies...
  • Page 25: Sample Program

    User Manual Digital Interface LAN – V 1.2 Digital Interface IP Functionality Instruction Sample (s) If unit-I ≥ 1 A: current declaration ampere Query of programed scaled CALibrate:CURRent? CAL:CURR? current value with reference to the DAC- resolution] In case of integrated CALibrate:RESistance <R >...
  • Page 26: Index

    Standard instruction set ..........9 Disclaimer ..............3 Technical specifications ..........5 Ethernet ..............5 Time response ............... 6 Extra instruction set ............ 10 User Manual ..............4 Front View ..............5 warranty ................ 3 Liability ................3 Heinzinger ® power supplies...
  • Page 27 D I S C L A I M E R The information contained in this document is subject to change without notice. Heinzinger electronic GmbH shall not be liable for errors contained in this document or for incidental or consequential damages in connection with the furnishing, performance or use of this material.
  • Page 28 Heinzinger electronic GmbH The Power Supply Company Anton-Jakob-Strasse 4 83026 Rosenheim – GERMANY Phone: +49-8031-2458-0 Fax: +49-8031-2458-58 info@heinzinger.de www.heinzinger.com V 1.2 26.09.2012 Heinzinger ® power supplies...

This manual is also suitable for:

76ip

Table of Contents