Retractor Series/2 • Installation Guide
This guide provides basic instructions for an experienced technician to install the Extron
Cable Retraction System with Speed Control for Cable Cubby
system can be installed in Cable Cubby, Cable Cubby Series/2, AVEdge™, and Cable
Cubby TouchLink
 Touchpanel enclosures, as well as the TMK 120 R Table Mount Kit.
®
Additional instructions are available in the user guides for the enclosures and TMK 120 R at
www.extron.com.
NOTE:
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics,
Extron Safety and Regulatory Compliance Guide
see the

Planning

The Retractor modules can be mounted in horizontal, vertical, or angular orientation depending on under‑table clearance and
accessibility.
Horizontal mounting is recommended to provide maximum legroom and to protect the modules against accidental damage.
Vertical mounting is used where insufficient under‑table space exists for horizontal mounting or under‑table access is limited.
Angular mounting is used where insufficient under‑table space exists for horizontal mounting and tabletop to floor clearance
prevents vertical mounting. The enclosure has additional mounting holes that enable mounting at a fixed angle between
vertical and horizontal.
NOTES:
For horizontal mounting, a mounting bracket kit is required.
Filler modules are required to occupy unused Retractor space.
For Retractor Series/2 DC modules, refer to the website for laptop compatibility. Always use a power supply
recommended by the laptop manufacturer.
Mounting kits, filler modules, and accessories are available at www.extron.com.
For new installations, to determine the best location for the enclosure, keep in mind the under‑table space required for the
retraction system. Refer to the enclosure installation guide to mount the enclosure.
NOTE:
When connectivity brackets, AAP plates, and AAP modules are relocated or removed to provide space for the
retraction system, associated hardware can require reconfiguration or replacement. Before starting an installation,
determine if additional hardware is needed.
Required Tools and Additional Accessories
Tweeker
Marker Pen
Hex Nut Driver
(10 mm)

Determine Under-Table Clearances

Follow the Retractor installation instructions provided in your enclosure user guide to determine a suitable mounting location.
The diagrams on the following page show the space required for a retraction system installation in a compatible enclosure.
NOTES:
To prevent objects from impeding cable retraction, ensure the exposed cable clears nearby obstructions.
Excess cabling can cause clearance issues. Use zip ties to secure under‑table cabling to prevent accidental contact or
entanglement with users.
Enclosures. The retraction
®
on the Extron website.
Tape Measure
Zip Ties
Phillips Screw Driver
Horizontal Mounting
Bracket (Optional)
Retractor Series/2 • Planning and Tools
Filler Module
(Optional)
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Retractor 2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Extron electronics Retractor 2 Series

  • Page 1 Retractor Series/2 • Installation Guide This guide provides basic instructions for an experienced technician to install the Extron Cable Retraction System with Speed Control for Cable Cubby Enclosures. The retraction ® system can be installed in Cable Cubby, Cable Cubby Series/2, AVEdge™, and Cable Cubby TouchLink  Touchpanel enclosures, as well as the TMK 120 R Table Mount Kit.
  • Page 2 Retractor Series/2 • Installation Guide (Continued) Mounting Orientation The Retractor modules are mounted from below the enclosure. Horizontal Mounting: Be certain the Horizontal Mounting Bracket can be fastened under the table or on a table support without Prepare the Enclosure bending the pulley system or forcing it from perpendicular with the enclosure (see on the next page.
  • Page 3 Product Category Prepare the Enclosure Ensure the retraction system has adequate under‑table clearance for installation and that proper legroom is provided to avoid accidental contact with the system. You should have the required accessories for mounting the retraction system and to configure the enclosure. DANGER: Horizontal Bracket...
  • Page 4 Retractor Series/2 • Installation Guide (Continued) Installation The enclosure must be installed and properly configured before beginning the retraction system installation. Follow the enclosure installation instructions for new installations, or prepare an existing enclosure installation to mount the Retractor modules. Follow the Retractor mounting instructions in the enclosure installation guide (see the example installation at right).
  • Page 5 Product Category Position the bracket inside the lines drawn in step 3 and fasten with the supplied screws. ATTENTION: • Ensure the supplied screws do not pierce through the top of the table. Use appropriate screws based on the table material and thickness. •...
  • Page 6 Retractor Series/2 • Installation Guide (Continued) Confirm Proper Cable Extension To extend the cable, hold it by the connector and pull the cable from the Retractor to its full length. Confirm Proper Cable Retraction To retract a cable, see the diagram at right. Press and hold the CAUTION: Use one hand to control...
  • Page 7 Product Category Laptop Power The Retractor Series/2 DC, Retractor Series/2 XL DC, Retractor Series/2 Lenovo DC, Retractor Series/2 XL Lenovo DC, Retractor Series/2 USB‑C Power, and Retractor Series/2 XL USB‑C Power modules provide a connection for a device on the tabletop to a compatible power supply (not supplied) under the furniture.
  • Page 8 Extron Safety and Regulatory Compliance Guide on the Extron website. www.extron.com © 2016‑2019 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. 68-2485-50 Rev. D Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876...

Table of Contents