AmZetta B.O.L.T Chest ECG User Manual

Body life tracker

Advertisement

Quick Links

BODY LIFE TRACKER
B.O.L.T Chest ECG User Manual
Document No : AMZ-PRD-UM-B-BE1
Version
: 2.0
Date
: 31-Aug-2020
ONE-TOUCH WIRELESS HEALTH TRACKER
Product Name: B.O.L.T BE1
Device Model Number: VA07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B.O.L.T Chest ECG and is the answer not in the manual?

Questions and answers

Summary of Contents for AmZetta B.O.L.T Chest ECG

  • Page 1 ONE-TOUCH WIRELESS HEALTH TRACKER BODY LIFE TRACKER B.O.L.T Chest ECG User Manual Product Name: B.O.L.T BE1 Device Model Number: VA07 Document No : AMZ-PRD-UM-B-BE1 Version : 2.0 Date : 31-Aug-2020...
  • Page 2 Call AmZetta Technologies Private Ltd at 1800-572-4061. Limitations of Liability In no event shall AmZetta Technologies Private Ltd be held liable for any loss, expenses, or damage of any kind whatsoever, whether direct, indirect, incidental, or consequential, arising from the design or use of this product or the support materials provided with the product.
  • Page 3 B.O.L.T Chest ECG User Manual Document History Version Date Comment 27-Mar-2019 Initial Release 31-Aug-2020 EC Rep and CE marking details removed © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 3...
  • Page 4: Table Of Contents

    Electromagnetic emissions ............. 28 12.2 Electromagnetic Immunity.............. 29 19.0 Warranty Information ................. 32 20.0 Customer Care Support ............... 32 21.0 Contact us ..................33 22.0 Applicable Label Symbols ..............34 © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 4...
  • Page 5: Intended Use

    2.0 Product Description B.O.L.T Chest ECG device is a portable monitoring system which can measure/monitor the electrical activity of the heart over a period of time using the ECG electrodes placed on the user`s body. The device monitors the single lead ECG waveform from the Left & Right chest with a reference Electrode.
  • Page 6: Package Contents

     Do not use the device when charging with a wall mount adapter as it may introduce noise in the waveform.  The ECG device must comply with regulation specified in warning and cautions. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 6...
  • Page 7: Essential Performance

     Do not disassemble, repair, or modify the device by yourself, as this could affect the safety, and voids the warranty of the device if the seal is broken. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 7...
  • Page 8  The ECG electrodes should not contact any other conductive surfaces or earth ground, at any time.  Exposure to unsuitable environmental conditions may cause the ECG device to malfunction and provide inaccurate readings. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 8...
  • Page 9  Servicing and troubleshooting procedures on the software or hardware components may only be performed by authorized service centers.  The power adapter is given only for charging the device and should not be used while charging. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 9...
  • Page 10: Caution

     Do not service or perform maintenance procedure while in use with patients.  Servicing and troubleshooting procedures on the software or hardware components may only be performed by authorized service centers. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 10...
  • Page 11: Calibration Verification Procedure

    If the fundamental procedure is not followed then the result obtained during the ECG monitoring will not be considered accurate, and therefore the test results are not acceptable. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 11...
  • Page 12: Product Features

    7.0 Operating Environment B.O.L.T Chest ECG device has been designed for use in the hospitals, clinics or directly by the patient at home to monitor the heart conditions. The user or the physician is responsible for ensuring that the device is stored and used in recommended environmental conditions as mentioned in the environmental specification given in the technical specification section in this user manual.
  • Page 13: Using Mobile Application

    You can also login as a guest user while internet unavailability which might not store the measured vital parameters in the cloud storage space on the measured parameters. Launch Screen Login Screen © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 13...
  • Page 14 B.O.L.T Chest ECG User Manual Measurement Screen Above application screens general illustration purpose only. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 14...
  • Page 15: Chest Ecg Measurement Procedure

    ECG device. RA is white color, LA is black in color and LL is red color. RA – Right Arm, LA – Left Arm & LL – Left Leg © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 15...
  • Page 16 8. Blue LED on the ECG device will start blinking, which means that the ECG device is searching for Bluetooth device for pairing. 9. Launch the B.O.L.T application from the mobile device. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 16...
  • Page 17 Ensure that the save option is enabled for storing the data in the cloud. For sync to occur successfully between the device and the tablet there must be a valid Bluetooth connection. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 17...
  • Page 18: Charging The B.o.l.t Chest Ecg Devices

    B.O.L.T Chest ECG device Charging Procedure:- 1. Connect the USB cable to the power adapter. 2. Connect the micro USB port to the ECG device`s power port (USB port). © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 18...
  • Page 19 7. To view the Battery Level, after pairing with the ECG device, Click battery icon at top right corner in the application. You can also view under settings option. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 19...
  • Page 20: Battery Care

    It is highly recommended changing the battery of the base unit for every 2 year at the authorized service center. Use manufacturer recommended battery for replacement. Both shelf life & service life of the battery is 2 year. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 20...
  • Page 21: Troubleshooting

    ECG device switched ON, but not Bluetooth pairing Restart the ECG device, showing in the list of the problem Then try to connect again. available Bluetooth device in the application © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 21...
  • Page 22 Used in dusty and accessories with a soft readings unstable environmental cloth dampened with 70% conditions isopropyl alcohol before measurement and ensure for use at a specified environmental conditions © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 22...
  • Page 23: Technical Specifications

    500 samples/second Resolution 24 bit Power Requirements Power Source DC 5V 2A Battery Type 3.7V 850mAh Li-Poly Battery Environmental Specification Operational Temperature +10 to +45 degree C © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 23...
  • Page 24: Explanation Of Indicators

    Steady green light indicates that the gadget is operating in battery mode. (Green) Steady red light indicates that the gadget is in the charging mode. (Red) Symbol for “DISPOSAL” Symbol for “Notes with additional Information” © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 24...
  • Page 25 While the B.O.L.T device is in a Bluetooth connection, it will be unavailable for other connections. Apart from the standard Bluetooth security measures, AmZetta has implemented a non-standard AmZetta defined security protocol to the B.O.L.T device that, if used, will restrict the transfer of data to only devices with a specified organizationally unique identifier (OUI).
  • Page 26: Certifications

     IEC 60601- 2-27:2011 Medical electrical equipment ─ Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment 2AFV6-AMI-ECG-02 © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 26...
  • Page 27: Fcc Compliance Statements

    — Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. www.amzbolt.com For more information kindly visit our website: © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 27...
  • Page 28: Emissions And Immunity Information

    EN 61000-3-2 Complies the public low-voltage power supply network that supplies buildings used for domestic purposes. Voltage fluctuations / flicker emissions EN 61000-3-3 Complies © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 28...
  • Page 29: Electromagnetic Immunity

    At 0°, 45°, 90°, 135°, 315° and voltage 180°, 225°, 270° and variations on 315° 0 % UT; 1 Cycle power supply input lines 0 % UT; 1 Cycle © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 29...
  • Page 30 EN 61000-4-8 typical commercial or hospital 30 A/m 30 A/m environment. Note: UT is the AC mains voltage prior to application of the test level. © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 30...
  • Page 31 RF wireless communications communications Interference may occur in the equipment (As per equipment (As vicinity of equipment marked with table 9) the following symbol: per table 9) © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 31...
  • Page 32: Warranty Information

    Any other reason external to the equipment (e.g.: accidents, vibrations etc.) 20.0 Customer Care Support AmZetta Technologies Private Ltd `s flexible approach allows the customers to get Technical Support and Warranty services for B.O.L.T through our customer care support.
  • Page 33: Contact Us

    Off. Rajiv Gandhi Salai (OMR) Chennai (TN) 600119, India. Tel – 044-61240022, 044-30165922; Fax – 044-61240025 Toll-free number (India): 1800–572–4061 Toll-free number (USA): 1833-222-5444 Email: support@amzbolt.com Website: www.amzbolt.com; www.amzetta.co.in © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 33...
  • Page 34: Applicable Label Symbols

    Symbol for “Fragile” Symbol for “Protect from heat and radioactive sources indication” Symbol for “KEEP DRY” Symbol for “Follow Instructions for use” Symbol for “TYPE BF APPLIED PARTS” © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 34...
  • Page 35 ENCLOSURE is tilted up to 15° angle Symbol for “Do not Reuse” Symbol for “Indicating that the manufacturer`s instructions for use are available in an electronic format” © Copyright 2020, All Rights Reserved. AmZetta Technologies Private Ltd. Page | 35...

This manual is also suitable for:

B.o.l.t be1Va07

Table of Contents