Table of Contents

Advertisement

Quick Links

IMPORTANT!—Before You Begin
Activate/Register Your NGS Mach II
The first time you power up NGS Mach II you will be prompted to go to our website at
www.hickok-inc.com
given an unlock code to enter into NGS Mach II. This procedure must be completed before you can begin
to use NGS Mach II. To activate, power up the NGS Mach II and follow the on-screen instructions. When
entering the unlock code:
• Use the numbered 2 and 5 keys or the dial to move the cursor to the right or left.
• Use the numbered 3 and 4 keys to increase or decrease the number/letter.
• Press ENTER to activate. NGS Mach II saves the code to memory and then displays the Main menu.
Check for Updated Software
After you activate/register your NGS Mach II, be sure to visit the DOWNLOAD CENTER at our
website
www.hickok-inc.com
IMPORTANT!
If an update is available, make sure to download the installation instructions
and the software update.
• If you need to install Microsoft® .Net Framework 1.1 Software (see the
update installation instructions) a copy is included on your NGS Mach II
Documentation CD.
About This Guide
This user guide provides you with instructions on setting up and operating NGS Mach II. However,
information in this guide is subject to change without notice. Please check our website at
www.hickok-inc.com
In addition to the bookmarks to the left of the screen, links are provided for your convenience
throughout this manual. They are red in color and underlined for easy identification. You can also
use the listings in the table of contents as links.
NGS Mach II Documentation CD Contents
The NGS Mach II Documentation CD includes the following documents:
• NGS Mach II User Guide
• Microsoft® .Net Framework 1.1 Software
• Driver Software for use with the Computer Interface Cable with USB Adapter
NGS Mach II User Guide v1.1
to activate/register the unit. Once you have completed the registration, you will be
to ensure you have the most recent software available.
for any possible changes that were made to this guide after printing.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NGS Mach II and is the answer not in the manual?

Questions and answers

Summary of Contents for Hickok NGS Mach II

  • Page 1 IMPORTANT!—Before You Begin Activate/Register Your NGS Mach II The first time you power up NGS Mach II you will be prompted to go to our website at www.hickok-inc.com to activate/register the unit. Once you have completed the registration, you will be given an unlock code to enter into NGS Mach II.
  • Page 2: Table Of Contents

    Contents Saftey Information....................5 Getting Started ..................... 6 Components..........................6 Using the NGS Mach II Controls ..................... 7 Numbered keys (screen buttons 1–6) ............................7 Cancel buttons ....................................7 Arrow buttons .....................................7 Trigger buttons ....................................7 Dial .........................................7 Blue LEDs ..........................8 12V PWR ........................................8 DATA LINK ......................................8...
  • Page 3 PATS Functions....................33 About PATS Programming ....................33 General Guidelines ....................... 33 Add New Keys (Ignition Key Code Program) ................ 34 Programming Without NGS Mach II..................35 Single Key Procedure..................................35 Dual Key Procedure..................................35 Erasing & Reprogramming Keys ................... 36 (Ignition Key Code Erase)......................
  • Page 4 Retrieve Data —Non-CAN Vehicles..................43 Restore Data —Non-CAN Vehicles ..................44 Software Updates ....................46 Connecting NGS Mach II to a PC ................... 46 Installing the Software Driver ....................46 Procedure for Windows®XP Professional with Service Pack 2 or Higher ................. 46 Procedure for Windows®2000 Professional with Service Pack 4 ..................
  • Page 5: Saftey Information

    This will cause the flames to spread instead of extinguishing them. • Use a dry chemical extinguisher to fight flames (preferably one marked ABC, though BC is acceptable). A foam extinguisher is acceptable only if it is ARF grade, which is resistant to alcohol. NGS Mach II User Guide v1.1...
  • Page 6: Getting Started

    NGS Mach II software. Also requires using the Auxiliary Power Cable. Auxiliary Power Cable Use to supply power to NGS Mach II when using either the EEC-IV Adapter cable, the Computer Interface Cable, or when the VPWR is missing from the vehicle’s OBDII connector.
  • Page 7: Using The Ngs Mach Ii Controls

    Getting Started Using the NGS Mach II Controls NGS Mach II has a variety of options for navigating through the software and selecting menu items. Numbered keys (screen buttons 1–6) Use for various functions depending upon the active screen. Cancel buttons Use to end functions and exit screens.
  • Page 8: Blue Leds

    NGS Mach II turns on automatically when connected to power (via the OBDII/EEC V Adapter Cable or the Auxiliary Power Cable). When powering on, NGS Mach II beeps and the LEDs flash. Once the unit is powered on and the Main menu is displayed, some LEDs stay on to alert you to the status of NGS Mach II.
  • Page 9: Vehicle & Power Connections

    NGS Mach II to communicate with a PC. Vehicle Hookup Procedures Before you begin, make sure the vehicle’s ignition key is in the OFF position, and that NGS Mach II is not connected to power. 1. Connect the appropriate adapter cable to...
  • Page 10: Selecting A Vehicle, Module And Action

    — TRIGGER. by a + or – in the column after engine size For flexibility, NGS Mach II allows you to 2008 - VIN #10 : 8 2007 - VIN #10 : 7 choose a vehicle that is different from the...
  • Page 11: Selecting A Module

    NGS Mach II displays the selected 4)GO -> vehicle in the Main menu: SELECT ITEM AND PRESS TRIGGER TO START 2. NGS Mach II displays a list of modules for 1 )MODEL : 2008 CROWN VICTORIA 4.6L 2)MODULE: _ _ _ _ the vehicle selected.
  • Page 12: Selecting An Action

    3)ACTION : EVAP TESTS 4)GO -> SELECT ITEM AND PRESS TRIGGER TO START 2. NGS Mach II displays a list of actions for the vehicle and module selected. Note: For non-CAN vehicles, you will be Highlight the desired action, and then prompted to reselect the following (press press TRIGGER.
  • Page 13: Service Bay Functions

    Lighting Configure Audio Control Module Driver’s Door Module • Programmable Module Installation • Programmable Module Installation • Audio Configure • Keyfob Programming Procedure Instrument Cluster Module/Hybrid Electronic Cluster • Programmable Module Installation • PATS Programming NGS Mach II User Guide v1.1...
  • Page 14: Procedure

    1. Press VIEW to display the samples you SERVICE BAY FUNCTIONS * RETURN TO MAIN MENU * recorded. 2. NGS Mach II prompts you to select the recording area you wish to view. 3. Select an area by pressing the SELECT ITEM AND PRESS TRIGGER TO START corresponding number.
  • Page 15: Diagnostic Functions

    PID Data • Active Command Modes Restraint Control Module • Function Tests • Diagnostic Test Modes • Module ID • PID Data • DTC Library • Active Command Modes • Module ID • DTC Library NGS Mach II User Guide v1.1...
  • Page 16: Basic Procedure For Can Vehicles

    MY 2004 THRU CURRENT MY VEHICLES 4)GO -> SELECT ITEM AND PRESS TRIGGER TO START 6. Highlight the desired option and then press TRIGGER. Follow the instructions on the screen to run the diagnostic test. NGS Mach II User Guide v1.1...
  • Page 17: Test Descriptions

    PIDs. DIAGNOSTIC TROUBLE CODE LIBRARY ACTIVE COMMAND MODES MODUE IDENTIFICATION Note: NGS Mach II can monitor PIDs for all modules on the same link. SELECT ITEM AND PRESS TRIGGER TO START Choose a module to access related PIDs.
  • Page 18 PIDs you’ve selected, you capture Activates the right window. only the part of that recording you wish CLEAR to save. NGS Mach II prompts you to press Deselects all PIDs. TRIGGER to capture data: BLOCK Toggles on and off the block function that allows you to select 3.66 V...
  • Page 19 DDL’s SETUP Button no pre-TRIGGER data. Vehicles with the communication link DDL Note: NGS Mach II determines the length have a setup button on the PID screen. When you press SETUP, you get these functions: of the time frame for the captured recording based on the data, the PIDs and the communication link.
  • Page 20: Retrieve/Clear Continuous Dtcs

    Vehicle & Engine Selection. If you made an incorrect Vehicle and Engine Selection, the displayed codes will be incorrect for the vehicle you’re testing. Press CANCEL to return to the Main Menu. NGS Mach II User Guide v1.1...
  • Page 21: Active Command Modes

    • Press TRIGGER to lock in the starting • press TRIGGER to toggle point. OFF and ON. AUTO mode • Turn the dial to highlight the desired sends the signal as soon as block of PIDs. you change a value. NGS Mach II User Guide v1.1...
  • Page 22: Module Identification

    An asterisk marks each selected PID. 4. The screen displays the results after tests DEFN Press in any PID screen are finished. to display definitions of highlighted PIDS. Press CANCEL to exit the DEFN screen. NGS Mach II User Guide v1.1...
  • Page 23: View Recorder Areas

    3)ACTION : VIEW RECORDER AREAS 4)GO -> VIEW RECORDED DTCS if you want to see the DTCs). NGS Mach II displays the vehicle SELECT ITEM AND PRESS TRIGGER TO START data to help you identify the area’s contents. 6. Now select up to four PIDs for playback.
  • Page 24: Reviewing Recorded Information

    • as it changes during the recording time; the cursor is flush left. Move it away from the edge of the screen by turning the dial clockwise. • as it compares to other PID values. NGS Mach II User Guide v1.1...
  • Page 25 PRINT This option is not available at this time. REW, PLAY, FWD and STOP act like the controls on a tape recorder.You can move forward and backward through the recording by pressing these buttons. NGS Mach II User Guide v1.1...
  • Page 26: Power Balance

    (press TRIGGER after each selection): • SELECT NEW VEHICLE YEAR & MODEL SERVICE BAY FUNCTIONS *RETURN TO MAIN MENU* • Select model year SELECT ITEM AND PRESS TRIGGER TO START • Select vehicle and engine • Confirm selection NGS Mach II User Guide v1.1...
  • Page 27 SELECT ITEM AND PRESS TRIGGER TO START MISFIRE COUNT RPM = 681 REFRESH NGS Mach II displays this screen: An RPM scale is listed down the left side of the graph and shows the percentage of -MAKE SURE AREA IS WELL VENTILATED- change in relation to the other cylinders.
  • Page 28: Evap Testing

    1 )MODEL : 2008 CROWN VICTORIA 4.6L RCM -RESTRAINT CONTROL MODULE 2)MODULE: PCM - POWERTRAIN CONTROL MOD 3)ACTION : EVAP TEST 4)GO -> SELECT ITEM AND PRESS TRIGGER TO START SELECT ITEM AND PRESS TRIGGER TO START NGS Mach II User Guide v1.1...
  • Page 29 SELECT ITEM AND PRESS TRIGGER TO START 9. After completing the test, check and clear any DTCs that may have been generated. NGS Mach II displays this screen: -START ENGINE, DO NOT PRESS THROTTLE -FUEL LEVEL MUST BE BETWEEN 15% & 85% -CLEAR DTCS AT END OF TEST.
  • Page 30: Generic Obdii Functions

    This test is only available for non-CAN vehicles NGS Mach II can link with any non-CAN vehicle that is OBDII compliant, offering several options for diagnosing OBDII related problems. Hook up NGS Mach II to the vehicle with the OBDII Adapter Cable connecting to the vehicle’s Generic Scan Tool Connector.
  • Page 31: Function Descriptions

    CLEAR Deselects all PIDs. 45.00 45.75 45.75 Selects all PIDs. START Begins monitoring. NGS displays the (1) RICH TO LEAN THRESHOLD VOLTAGE PID, the data and the node address of the module sending the data. NGS Mach II User Guide v1.1...
  • Page 32: Diagnostic Monitoring Test Results

    (1) RICH TO LEAN THRESHOLD VOLTAGE On Board Device Control Allows you to control output devices within TEST# the responding module’s node the system. NGS Mach II lists specific tests address, the test ID number, the available for the selected vehicle. component number MEAS...
  • Page 33: Pats Functions

    PATS related information. PATS II—applies to model years 1998– current Spare Keys—If you need additional spare keys NGS Mach II automatically determines which after completing this procedure, see Add New PATS type is applicable for programming keys Keys.
  • Page 34: Add New Keys (Ignition Key Code Program)

    PATS Functions Add New Keys (Ignition Key Code Program) When the programmed keys are not available, this procedure allows NGS Mach II to add keys to PATS II systems. Note: For PATS I systems, or when the programmed keys are available, see Programming Without NGS Mach •...
  • Page 35: Programming Without Ngs Mach Ii

    This procedure uses the vehicle’s programmed keys to add keys (up to the number of maximum keys) to the module without using NGS Mach II. 1. Cut the number of keys you want to add to the vehicle (refer to the vehicle’s shop manual).
  • Page 36: Erasing & Reprogramming Keys

    • Make sure to use blank unprogrammed keys when reprogramming • Make sure the vehicle’s battery is fully charged—disconnect NGS Mach II from the vehicle if the battery needs charging. Procedure: 1. Cut the number of keys you want to add 9.
  • Page 37: Setting The Spare Key Switch (Pats Ii Only)

    • Make sure to use blank unprogrammed keys when reprogramming • Make sure the vehicle’s battery is fully charged—disconnect NGS Mach II from the vehicle if the battery needs charging. Procedure: 10. Highlight ENTER SECURITY ACCESS and 1.
  • Page 38: Reprogramming After A Pcm Module Replacement

    • Verify the ignition key is in the OFF position before reconnecting the battery. Before You Begin Make sure the vehicle hookup and NGS Mach II setup are completed. If not, complete before continuing. Accessing Vehicle Information Using the vehicle’s shop manual: 1.
  • Page 39: Procedure For Pats Ii Systems With Hec, Vic, Icm, Or Pats Module

    12. Disconnect NGS Mach II from the vehicle. VIC, ICM, or PATS Module 13. Cycle the ignition key from OFF to RUN 5 1. With NGS Mach II connected to the vehicle times. insert the key into the ignition. • Make sure to leave the key in RUN for at 2.
  • Page 40: Programmable Module Installation

    • To overwrite the data stored in NGS and retrieve the data from the module press TRIGGER and proceed to step 6. • To keep the currently stored data press CANCEL to exit the procedure. NGS Mach II User Guide v1.1...
  • Page 41 To exhale data immediately after an inhale, proceed to step 3. -XXX INHALE IN PROGRESS- Note: If you powered off NGS Mach II, you will need to start from step 1. 1. Select the Vehicle, Module, and Action (PMI- Programmable Module Installation) from the Main Menu.
  • Page 42 Press any key to exit and return to the OK TO OVERWRITE XXX MODULE DATA? Service Bay Function screen. PRESS TRIGGER TO OVERWRITE PRESS CANCEL TO EXIT Note: NGS displays the actual module selected. NGS Mach II User Guide v1.1...
  • Page 43: Retrieve Data -Non-Can Vehicles

    SELECT ITEM AND PRESS TRIGGER TO START SUPPORT: MY 1994 TO CURRENT MY SCP ISO APP ID : NON CAN SERVICE BAY SELECT RETURN TO MAIN MENU ABOVE FOR MY 2004 THRU CURRENT MY VEHICLES NGS Mach II User Guide v1.1...
  • Page 44: Restore Data -Non-Can Vehicles

    NGS UP TO 48 HOURS. TO PREENT DATA LOSS, DO NOT RETRIEVE MODULE DATA UNTIL NEW MODULE IS AVAILABLE. Note: If you powered off NGS Mach II, you will - PRESS TRIGGER TO CONTINUE. need to start from step 1.
  • Page 45 PRESS ANY KEY TO CONTINUE RETRIEVE MODULE CONFIG-OLD ECU RESTORE MODULE CONFIG-NEW ECU Press any key to exit and return to the Service Bay Function screen. SELECT ITEM AND PRESS TRIGGER TO START 7. NGS displays this message: NGS Mach II User Guide v1.1...
  • Page 46: Software Updates

    Installing the Software Driver When using the computer interface cable with the USB adapter, you may need to install the software driver for the adapter.This software is located on the NGS Mach II Software Driver and Documentation CD. IMPORTANT! • You may need Administrator privileges to install this software.
  • Page 47: Procedure For Windows®2000 Professional With Service Pack 4

    Windows detects the adapter and displays the installing New Hardware screen. 11. When finished, Prolific USB-to-Serial Comm Port, Device driver software installed successfully is displayed. Wait for the screen to disappear, then restart your computer. NGS Mach II User Guide v1.0...
  • Page 48: Troubleshooting

    Troubleshooting General Error Messages The following is a list of error messages you may encounter when using NGS Mach II and the suggested action to take to correct the error. IMPORTANT! The suggested actions to take are for reference only. Always refer to the vehicle’s shop manual for proper diagnostic procedures.
  • Page 49: Lcd Contrast Needs Adjusted

    The vehicle has a blown fuse. Either replace the fuse, or use the auxiliary power cable. Blank Screen at Start-Up If NGS Mach II beeps at start-up but the screen remains blank, adjust the contrast by following these steps: 1. Wait 20 seconds for start-up to finish.
  • Page 50: Specifications

    0° to 50°C Storage –20° to 70˚ Humidity Operation and storage 10%–95% relative humidity, noncondensing Power Specifications Operating voltage 8.5–18VDC Power Consumption 5W nominal, 0.5A maximum Unit dimensions 13.5” L x 9.0” W x 2.0” NGS Mach II User Guide v1.0...
  • Page 51: Warranty

    Warranty Hickok Inc. warrants this instrument of its manufacture to be free from defects in materials and workmanship for a period of thirteen (13) months from the date of original purchase, subject to the following conditions: • Any instrument found to be defective during the stated warranty period may be returned, transportation prepaid, to the factory for repair or, at the option of Hickok, replaced without charge.
  • Page 52: Legal Information

    No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, without written permission from Hickok. Hickok assumes no responsibility for use of this equipment by untrained or unauthorized persons. Printed in the United States of America.
  • Page 53: Contact Information

    1716 Carrollton Avenue Dock E Greenwood, MS 38930 Don’t forget to check out other testers, equipment and parts at our websites. Access our Quick-n-EZ Parts and Service from any of these sites 24/7 for ordering parts or service. NGS Mach II User Guide v1.0...

Table of Contents