MHS400.
Motorised lift & slide system for schemes A and C.
W I N D OW HARDWARE
D O O R H A RDWAR E
S L I D I N G D O OR HAR DWAR E
V E N T IL AT I O N T EC HNO LOGY
B U IL D IN G TEC HN OLO GY
A S S EM BL Y I NS T RU CT I O NS
BU IL DI N G TEC HN OLOGY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MHS400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Siegenia MHS400

  • Page 1 A S S EM BL Y I NS T RU CT I O NS MHS400. Motorised lift & slide system for schemes A and C. W I N D OW HARDWARE D O O R H A RDWAR E BU IL DI N G TEC HN OLOGY...
  • Page 3: Table Of Contents

    Original operating instructions MHS400 1. Information ....................................2 1.1 Technical information.................................2 1.1 Technical information ................................3 1.2 Technical information - Scheme A ............................4 1.3 Scope of delivery - Scheme A ............................5 1.4 Technical information - Scheme C ............................7 1.5 Scope of delivery - Scheme C ............................8 1.6 Use ....................................
  • Page 4: Information

    (e.g. HS-PORTAL 200, HS-PORTAL 300 and HS-PORTAL 400), it opens, closes and locks lift & slide sashes at the touch of a button. Furthermore, the MHS400 lift & slide system can even be assembled on lift & slide elements by third- party manufacturers and retrofitted to previously installed lift &...
  • Page 5: Technical Information

    Features • Automatic teach-in and calibration of the lift & slide sash with reference run on first operation of the MHS400 lift & slide system • High level of functional reliability: Tested with 400 kg for more than 20,000 switching cycles •...
  • Page 6: Technical Information - Scheme A

    200 kg Sash weight HS-PORTAL 300 max. 300 kg Sash weight HS-PORTAL 400 max. 400 kg Max. permissible sash weight for MHS400 lift & slide drive max. 400 kg Backset (gear) HS-PORTAL 200 27.5 mm Backset (gear) HS-PORTAL 300 37.5 mm...
  • Page 7: Scope Of Delivery - Scheme A

    Ordering data and part list - Scheme A Description RIB in mm Colour Material number *MHS400 lift & slide system size 1 1775 - 2753 RAL 9003 white GMHS0010-000010 (must be ordered using special order form) Silver ~ RAL 9006 *MHS400 lift &...
  • Page 8 MHS400 Assembly instructions Component and accessories overview - Scheme A Accessories (not included in scope of delivery) Scope of delivery of individual components Last update: 17.12.2014...
  • Page 9: Technical Information - Scheme C

    200 kg Sash weight HS-PORTAL 300 max. 300 kg Sash weight HS-PORTAL 400 max. 400 kg Max. permissible sash weight for MHS400 lift & slide drive max. 400 kg Backset (gear) HS-PORTAL 200 27.5 mm Backset (gear) HS-PORTAL 300 37.5 mm...
  • Page 10: Scope Of Delivery - Scheme C

    Ordering data and part list - Scheme C Qty Size by slide drive Size range in mm Colour Material number MHS400 lift & slide system size 1 2812 – 5506 RAL 9003 white GMHS0040-000010* (1 slide drive each on left and right)
  • Page 11 Assembly instructions MHS400 Component and accessories overview - Scheme C (by lift & slide sash) Accessories (not included in scope of delivery) Scope of delivery of individual components * Use profile connectors to connect the cover profiles (SA) on the left and right at and above total length of 7000 mm.
  • Page 12: Use

    An individual drive for lift & slide elements in DIN left or DIN right is supplied (in accordance with the information supplied on the special order form for the MHS400 lift & slide system for either scheme A or scheme C at the time of placing the order).
  • Page 13: Safety Information And Hazard Warnings

    The concealed mains supply lines to the MHS400 lift & slide system must be connected in branch boxes; these branch boxes must be easily accessible for maintenance. › When cleaning the lift & slide sash and the drives, make sure that no liquid gets inside the MHS400 lift & slide system as this could damage the electronics. ›...
  • Page 14: On-Site Risk And Hazard Analysis In The Planning Phase

    A risk analysis provides you with all the information needed to assess risks and make decisions concerning the safety of the window elements. With the MHS400 lift & slide system, there are areas on the lift &...
  • Page 15: Assembly

    Preparations for assembly The MHS400 system must always be installed by an experienced and qualified window specialist, in accordance with the installation and planning documents issued by SIEGENIA. If you have any questions about installation, please contact the head of the relevant department at SIEGENIA or your window specialist.
  • Page 16: Assembly Requirements

    You must assemble the MHS400 system first before putting it into operation. • When operating the MHS400 system for the first time, you must carry out a reference run as well as a calibration and teach- in run which determines the traverse path and the traverse forces of the lift & slide sash automatically (see operating instruc- tions).
  • Page 17 You must assemble the MHS400 system first before putting it into operation. • When operating the MHS400 system for the first time, you must carry out a reference run as well as a calibration and teach- in run which determines the traverse path and the traverse forces of the lift & slide sash automatically (see operating instruc- tions).
  • Page 18 Requirements to be met by the hardware • In order for the MHS400 system to function properly, a compatible lift & slide fitting for opening scheme A or C with 10 mm square striker packer must be installed in the gear (e.g. HS-PORTAL 200, HS-PORTAL 300 or HS-PORTAL 400).
  • Page 19: Information About Mains Cable Fitting

    Option A — Surface-mounted fitting of mains cable The MHS400 system is delivered as standard with a 5 m long mains cable for scheme A and a 3.5 - 5 m long mains cable for scheme C (depending on the width of the element). The cable outlet for scheme A is always at the top of the slide drive SA on the locking side (Fig.
  • Page 20 MHS400 Assembly instructions Option B — Concealed fitting of mains cable If the customer is responsible for the concealed fitting of the mains cable for the slide drive SA and the connection of the slide drive SA (in the power supply for scheme A, in the 5-pin socket for scheme C), this work must be carried out by a qualified .
  • Page 21: Drilled Holes On The Lift & Slide Sash

    MHS400 2.3 Drilled holes on the lift & slide sash Positioning and setting the catch jig MHS400 (accessories) For accurate positioning of the catch and smooth cable fitting on the lift & slide sash, the following steps MUST be completed...
  • Page 22 Ø 15 mm (Fig. 5 and 6). The through hole can be drilled with the through hole jig MHS400 (see Fig. 6); this is available as an accessory. • Through holes do not have to be drilled for lift & slide PVC and aluminium profiles. If necessary, the slider support can be ma- chined to accommodate the cable channel.
  • Page 23 Assembly instructions MHS400 Drilled holes for lift drive HA and cable feed-through Assembly step 3: Drill the holes for the square for the lift drive HA and the cable feed-through on the locking side of the lift & slide sash. There are two options for drilling the holes.
  • Page 24 MHS400 Assembly instructions Drilled holes for lift drive HA and cable feed-through Option B — Extended gear recess on new lift & slide element If the gear recess is long enough, there is no need to drill a hole for the cable feed-through at the side to the lift drive HA.
  • Page 25: Cable Fitting In The Lift & Slide Sash

    Assembly instructions MHS400 2.4 Cable fitting in the lift & slide sash Cable fitting in the fitting groove (locking side lift & slide sash) Assembly step 4: To avoid damaging the cable (flat ribbon cable, 6-wire) in the lift & slide sash, the following information must be heeded: •...
  • Page 26 MHS400 Assembly instructions Cable fitting in the fitting groove (locking side lift & slide sash) Assembly sequence — Continued: • Run the cable through the cable outlet hole (Ø 15 mm) in the fitting groove of the lift & slide sash (Fig. 4 and 5). Excess cable length of if the lift drive HA is to be connected without problems (Fig.
  • Page 27 Assembly instructions MHS400 Preparing for cable installation in the sash groove at the top Important note: With some profiles with guide rail at the top, the cable holders can rub against the guide rail when the lift & slide sash is lifted. Actions for avoiding this are described below.
  • Page 28 MHS400 Assembly instructions Cable installation in the sash groove at the top Proceed as follows when installing the cable in the lift & slide sash: • Run the cable in the sash groove at the top as far as the cable outlet hole (Fig. 1 and 2).
  • Page 29: Assembly Of The Lift Drive Ha

    Option B — Without recessed pull handle (standard for new lift & slide elements) A recessed pull handle does not have to be attached on the outside when using the MHS400 (Fig. B). Screws (included in scope of delivery) Last update: 17.12.2014...
  • Page 30 MHS400 Assembly instructions Fixing and e-connection of the lift drive HA on the lift & slide sash Screw connections and e-connection on the drive unit HA • Attach the drive unit of the lift drive HA to the fixing plate and fix in place with...
  • Page 31 The lift & slide hardware gear supports the option of a cylinder lock being installed by the customer as standard. Cylinder lock Note: When using the MHS400, in particular with new lift & slide elements, a cylinder lock should not be installed, because operation by an electric motor is not possible when the cylinder lock is locked.
  • Page 32 MHS400 Assembly instructions Lift drive HA in conjunction with a cylinder lock Installation of lift drive HA with cylinder lock and rose lock A cylinder lock can be used as an additional security measure (e.g. for intruder prevention in conjunction with WK 2 lift &...
  • Page 33: Assembly Of The Slide Drive Sa - Schema A

    Assembly instructions MHS400 2.6 Assembly of the slide drive SA - Schema A Horizontal positioning of the slide drive SA - Scheme A When measuring the RIB (inside frame width), take into account whether the lift & slide frame profile is being used with or without a cover.
  • Page 34 MHS400 Assembly instructions Vertical positioning and fixing of the slide drive SA - Scheme A Two screw levels (A or B) are provided to fix the slide drive SA to the top of the lift & slide frame profile. The slide drive is positioned and screwed on as appropriate for the installation situation of the lift &...
  • Page 35: Concealed Mains Cable Fitting And Connection - Scheme A

    Assembly instructions MHS400 2.7 Concealed mains cable fitting and connection - Scheme A Concealed fitting and connection in the power supply for slide drive SA - Scheme A If the customer is responsible for the fitting of the flexible mains cable (5 x 1.5 mm...
  • Page 36: Assembly Of The Light Curtain - Scheme A

    MHS400 Assembly instructions 2.8 Assembly of the light curtain - Scheme A Modifications to the MHS400 system are required for operation with a light curtain The suitable light curtain can be ordered from: Light curtain CEDES GmbH Elektronische Systeme Elzmatten 6...
  • Page 37: Assembly Of The Slide Drive Sa - Schema C

    Assembly instructions MHS400 2.9 Assembly of the slide drive SA - Schema C Horizontal positioning of the slide drive SA - Scheme C Both slide drives must be assembled dead centre between the two sash join edges. The two mounting angles must be posi- tioned next to each other (Fig.
  • Page 38 MHS400 Assembly instructions Vertical positioning and fixing of the slide drive SA - Scheme C Drilling holes on two screw levels (A or B) are provided to fix the slide drive SA to the top of the lift & slide frame profile. The slide drive is positioned and screwed on as appropriate for the installation situation of the lift &...
  • Page 39 Assembly instructions MHS400 Vertical positioning and fixing of the slide drive SA - Scheme C • Attach the cover cap for the catch (Fig. 4). • Connect the plug to the 5-pin socket and plug the connection cable (4-pin) into the board (Fig. 5).
  • Page 40: Concealed Mains Cable Fitting And Connection - Scheme C

    MHS400 Assembly instructions 2.10 Concealed mains cable fitting and connection - Scheme C Concealed fitting and connection in the power supply for slide drive SA - Scheme C If the customer is responsible for the fitting of the flexible mains cable (5 x 1.5 mm...
  • Page 41: Assembly Of The Light Curtain - Scheme C

    Assembly instructions MHS400 2.11 Assembly of the light curtain - Scheme C Modifications to the MHS400 system are required for operation with a light curtain The suitable light curtain can be ordered from: Light curtain CEDES GmbH Elektronische Systeme Elzmatten 6...
  • Page 42: Special Designs

    Checking the functionality of the lift & slide element manually with the MHS400 system installed So that friction and resistance can be identified during manual operation of the lift & slide sash, the MHS400 system should be decoupled from the sash. To do this, simply release the catch on the slide drive SA from the catch base on the lift & slide sash and pull out the plug of the connection cable for the lift drive HA in the slide drive SA.
  • Page 43: Lift & Slide Profile Systems

    (Ø 7 mm) for the supporting peg of the catch base (see Chapter 2, page 19). The dimension X is set at the jig MHS400 catch as appropriate for the lift & slide profile systems on the following pages.
  • Page 44: Vertical Sections At The Top For Timber Elements

    MHS400 Assembly instructions 3.2 Vertical sections at the top for timber elements Timber element with guide rail HH 0130-01/-02 56/171 34/91 Guide groove at Packer 68/107 68/92 Screw level: Dimension X: 29 mm Packer: 8 mm Reinforcement: None Use flat washers...
  • Page 45 Assembly instructions MHS400 Timber element with guide rail HH 03 56/212 Guide rail HH0130-03 34/118 92/107 92/92 Screw level: Dimension X: 25 mm Packer: None Reinforcement: None Last update: 17.12.2014...
  • Page 46: Vertical Sections At The Top For Pvc Elements

    MHS400 Assembly instructions 3.3 Vertical sections at the top for PVC elements KF element Aluplast HST 4000 Profile chamber Screw level: Dimension X: 37 mm Packer: None Reinforcement: None Run flat ribbon cable through profile chamber KF element Aluplast Ideal...
  • Page 47 Assembly instructions MHS400 KF element Inoutic Screw level: Dimension X: 31 mm Packers: None Reinforcement: None KF element Gealan S 8000 Screw level: Dimension X: 31 mm Packer: None Reinforcement: None Last update: 17.12.2014...
  • Page 48 MHS400 Assembly instructions KF element Kömmerling Eurodur VS Screw level: Dimension X: 44 mm Packer t=50 Packer: 10 mm Reinforcement: None Screw-on accessory made from Profile with cover Insert screw-on accessory KF element Profine Premidoor Screw level: Profile chamber Dimension X:...
  • Page 49 Assembly instructions MHS400 KF element Salamander Design iD Screw level: Dimension X: 29 mm Packer: None Reinforcement: None KF element Schüco Corona CT 70 HS Screw level: Dimension X: 32 mm Packer: None Reinforcement: None Last update: 17.12.2014...
  • Page 50 MHS400 Assembly instructions KF element Rehau S 712 Screw level: Packers Dimension X: 39 mm 13.5 Packers: 8 mm + 5 mm Reinforcement: None Profile with cover KF element Rehau S 785 Brilliant-Design Packer Screw level: Dimension X: 29 mm...
  • Page 51 Assembly instructions MHS400 KF element Veka Softline Screw level: Dimension X: 35 mm Packer: None Reinforcement: None KF element Veka Topline and Softline 70 Reinforcement 8.5 x 35 (adapt to drive width) Screw level: Dimension X: 29 mm Packer: None...
  • Page 52 MHS400 Assembly instructions KF element Veka Slide 70 26.5 Screw level: Dimension X: 32 mm Packer: None Reinforcement: None KF element Thyssen Polymer Screw level: Dimension X: 33 mm Packer: None Reinforcement: None Last update: 17.12.2014...
  • Page 53: Vertical Sections At The Top For Aluminium Elements

    Assembly instructions MHS400 3.4 Vertical sections at the top for aluminium elements LM element ALCOA RT 135 Doubling-up Packer Screw level: Dimension X: 35 mm Packer: 5 mm Reinforcement: None Note doubling-up! LM element Alcoa Kawneer 3572 Screw level: Dimension X:...
  • Page 54 MHS400 Assembly instructions LM element Cortizo Doubling-up Screw level: Packers Dimension X: 35 mm Packer: 5 mm Reinforcement: None Profile with cover Note doubling-up! LM element Hueck Doubling-up Screw level: Dimension X: 37 mm Packer: None Reinforcement: None Profile with cover Note doubling-up! Last update: 17.12.2014...
  • Page 55 Assembly instructions MHS400 LM element Heroal 070 Doubling-up Screw level: Dimension X: 36 mm Packer: None Reinforcement: None Note doubling-up! LM element Heroal S77 Hi Screw level: Dimension X: 34 mm Packer: None Reinforcement: None Last update: 17.12.2014...
  • Page 56 MHS400 Assembly instructions LM element Reynaers CP 130 Screw level: Dimension X: 54 mm Packer: 5 mm Reinforcement: None LM element Reynaers CP 155 LS Duorail Screw level: Dimension X: 35 mm Packer: None Reinforcement: None Last update: 17.12.2014...
  • Page 57 Assembly instructions MHS400 LM element Aliplast Ultraglide Reinforcement 2x38 mm Screw level: Dimension X: 38 mm Packer: 2.5 mm Reinforcement: None LM element SAPA-RC C 125 Screw-on accessory made from PVC or timber (screw in with A2 sash lifters 4.1 x 38)
  • Page 58 MHS400 Assembly instructions LM element Schüco Royal S 120+ Doubling-up Screw level: Dimension X: 37 mm Packer Packer: 5 mm Reinforcement: None Profile with cover Note doubling-up! LM element Schüco ASS 70.HI (formerly: Royal S 160 HI) Screw level: Dimension X:...
  • Page 59 Assembly instructions MHS400 LM element Wicona WSL 160 Screw level: Dimension X: 39 mm Packer: 5 mm Reinforcement: None LM element Wicona Wicslide 23 Packer Screw level: Dimension X: 35 mm Packer: 10 mm Reinforcement: None Profile with cover Last update: 17.12.2014...
  • Page 60 MHS400 Assembly instructions LM element Aluprof MB 77 Screw level: Dimension X: 34 mm Packer: None Reinforcement: None Last update: 17.12.2014...
  • Page 61: Information Concerning Product Liability

    Incorrect use • Lift & slide elements that are equipped with the MHS400 lift & slide system must not be used as escape doors/emergency exits in the event of a fire. • Any use of this product that is not in accordance with its intended use, or any adaptation of or modification to the product and its associated components for which the express consent of SIEGENIA has not been obtained, is strictly prohibited.
  • Page 62: Ec Declaration Of Incorporation

    MHS400 Assembly instructions 5. EC declaration of incorporation Manufacturer: SIEGENIA-AUBI KG Hardware and ventilation technology Duisburger Straße 8 57234 Wilnsdorf, Germany declares that the product: Motorised lift & slide system Device type MHS400 Type designation meets the following fundamental requirements:...
  • Page 64 Switzerland Phone: +41 33 3461010 You can fi nd address details for our Germany Phone: +49 271 39310 Turkey Phone: +90 216 5934151 international sites at: www.siegenia.com Great Britain Phone: +44 2476 622000 Ukraine Phone: +380 44 4637979 Contact your dealer:...