Small, common mode EMI/EMC Filters in 150kHz to 1MHz (1-Stage filter)
EAC series
R
The terminal cover is retracted inside the unit
Features of EAC series
Small, common mode EMI/EMC Filters in 150kHz to 1MHz(1-Stage filter)
- Single Phase 250 VAC
Specifications
No.
Items
1
Rated Voltage[V]
2
Rated Current[A]
3
Test Voltage (Terminal-Mounting Plate)
4
Isolation Resistance (Terminal-Mounting Plate)
5
Leakage current 125/250V 60Hz
6
DC resistance
7
Safety agency approval temperatures
8
Operating temperature
9
Operating humidity
10
Storage temperature/humidity
11
Vibration
12
Impact
13
Safety agency approvals
14
Case size (without projection) /Weight
Circuit Diagram
Case
1
LINE
2
CY : Line to ground capacitor
EA/ES-1
EAC-03-472
AC 1f 250 / DC250
3
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
500 VDC 500MW min at room temperature and humidity
0.5mA/1.0mA max
180mW max
-25 to +85C (Refer to Derating Curve)
-40 to +85C (Refer to Derating Curve)
20 to 95%RH (Non condensing)
-40 to +85C/20 to 95%RH (Non condensing)
10 to 55Hz, 19.6m/s
196.1m/s
(20G), 11ms Once each X, Y and Z axis
2
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
39X30X85 mm [1.54X1.18X3.35 inches] (WXHXD) /170g max (Option : -D refer to external view)
3
CY
LOAD
CY
4
: Mounting Plate
July 08, 2020
Ordering information
EAC -10 -472
1
2
3
1 Model Name
2 Rated Current
3 Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
*
4 Options
DIN rail installation type is option
-Small-size
-Quick and easy push-down terminal
Just connect the wires,push-down and tighten
the screws with a screwdriver
EAC-06-472
EAC-10-472
EAC-16-472
6
10
16
110mW max
40mW max
20mW max
(2G), 3min. Period, 1hour each X, Y and Z axis
2
Derating Curve
100
80
60
40
20
0
-40
-30
-20
Ambient Temperature [C]
-O
4
Line to ground
Leakage Current
Code
capacitor
(Input 125/250V 60Hz)
(nominal value)
681
75.5
A/ 150 A max
102
0.13 mA/ 0.25mA max
222
0.25 mA/ 0.5 mA max
332
0.38 mA/ 0.75mA max
472
0.5 mA/ 1.0 mA max
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
D :DIN rail installation type
* The dimensions change when the option is set.
Refer to External view.
EAC-20-472
EAC-30-472
20
30
10mW max
6mW max
40
50
55
60
70
80
680pF
1000pF
2200pF
3300pF
4700pF
90
Need help?
Do you have a question about the EAC Series and is the answer not in the manual?
Questions and answers