Page 2
SPECIFICATIONS DIMENSIONS 10.25”H x 9.75”W x 3.75”D ELECTRICAL Unit Operates on: 115 VAC (24 VDC) provided power supply WEIGHT Wall Mount Version: 2.7 lbs. WARNINGS ** Electrical shock may occur. Hard-wired Installations should be handled by a licensed professional. ** Never service the unit while it is connected to a power source. Electrical shock or injury may occur.
Page 3
MAINTENANCE *******ALWAYS UNPLUG POWER SOURCE BEFORE SERVICING UNIT******* Cleaning The unit should be cleaned occasionally to ensure proper operation. 1. Remove the Cover Plate from the unit. 2. Wipe everything down with a damp cloth. 3. Replace the Cover Plate of the unit. Replacing the Filter We recommend washing the Filter every 90 days or when noticeably contaminated.
Page 4
Hg-LAMP CONTAINS MERCURY. Manage in accordance with disposal laws. (Visit www.lamprecycle.org for proper instructions.) TROUBLESHOOTING 1. Cell Doesn’t Turn On • Check for secure connection. • Try another Cell. • Ballast needs replaced. 2. Fan Doesn’t Turn On • Check for secure connection. • Fan needs replaced. WARRANTY WARRANTY LIMITED WARRANTY INFORMATION YOUR ADP-70 (PRODUCT) AND PCO CELL ARE EACH WARRANTED TO BE FREE FROM ALL DEFECTS IN MATERIAL AND...