Bartec ETC 480 Manual

Multifunctional digital thermostat with four operation modes for din installation

Advertisement

Quick Links

ETC 480 Bartec
Multifunctional digital thermostat with four operation modes for DIN installation
EN
MANUAL DIN Thermostat

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ETC 480 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bartec ETC 480

  • Page 1 ETC 480 Bartec Multifunctional digital thermostat with four operation modes for DIN installation MANUAL DIN Thermostat...
  • Page 2: Table Of Contents

    Contents Included in the package ......................3 Accessories ..........................3 Installation ..........................4 Thermostat ............................4 Sensor ............................... 4 Introduction ..........................5 Four operation modes ........................5 Menu navigation ..........................6 Start menu ............................7 Display mode ............................8 Functions in display mode ......................... 8 Operation mode Heating .......................
  • Page 3: Included In The Package

    Included in the package 1. Thermostat 3. Sensor cable 3m 2. Quick guide Accessories Depending on how you are going to use your thermostat, you may need to complement it with some of the parts below. 1. Sensor cable 3 m (High temperature sensor) You need to use this part if you are going to control temperatures above +75°C.
  • Page 4: Installation

    Installation Thermostat The thermostat must be installed on a DIN standard rail (EN 50022-35) in a normskåp with the applicable encapsulation class. The thermostat is IP20 classed and intended for installation in environments with a temperature range of -20°C to +45°C. The thermostat has 14 terminal blocks numbered according to the wiring diagram below: The incoming phase and...
  • Page 5: Introduction

    INTRODUCTION Introduction The manual, like the thermostat, is divided into four operation modes so that you only need to read about the functions you will use. The thermostat operation mode can only be installed in the start menu, which is shown the irst time the thermostat is started (read more about the start menu on page ...
  • Page 6: Menu Navigation

    INTRODUCTION Menu navigation The functions in the thermostat are arranged in a system of menus and sub menus. The Main menu always contains three submenus TEMP PROGRAM SYSTEM There are further choices under these. The irst time the thermostat is started, a number of requisite values must be set in the START menu (see page 7).
  • Page 7: Start Menu

    INTRODUCTION Start menu The start menu is used to quickly and simply set the three requisite basic settings; it is only shown the irst time the thermostat is switched on (or if the thermostat is fully reset using the reset function). Begin by choosing a language, continue with the date and time setting, and inish of by setting operation mode and sensor.
  • Page 8: Display Mode

    INTRODUCTION Display mode The display mode is the thermostat's "normal" mode; the most important settings, statuses and functions are shown and set here. The display shows, alternatingly, the set point and current values at the same time as it always shows the operation mode and if the installation is switched on or of.
  • Page 9 INTRODUCTION [press Connection time To see the total and momentary connection times*, press when the thermostat is in display mode. The counter shows the total hours the thermo stat has been connected for as well as the momentary time, in the same way as a vehicle trip meter, i.e.
  • Page 10: Operation Mode Heating

    Operation mode Heating Heating mode is used in homes, oices, storerooms and such like. With this operation mode, you can regulate the heating within a temperature range of +5°C to +45°C. The thermostat can be used as a loor thermostat, room thermostat or room thermostat with over heating protection for wood loors.
  • Page 11: Program Menu

    The surface temperature is an average value and varies somewhat depending on the material and the thickness. Denser (harder) wood insulates less than softer wood, which increases the surface temperature. Also, the thinner the loor, the higher the surface temperature. Two sensors are required for over heating protection: a room sensor (sensor A) and an over heating protection sensor (sensor B).
  • Page 12 The temperature can be set between +5°C and +45°C. The thermostat works from the temperature that is set in the manual program where the factory setting is +22°C. If you change the temperature in the manual program, or the set point in menu, the thermostat works from the new temperature, and lowers the TEMP temperature by +5°C from the newly set temperature.
  • Page 13: System Setting Menu

    Personal program [PERSONAL] Manual setting of the program allows optimisation of energy consumption to suit just your needs by making settings for four events each day: WAKE AWAY HOME . There are three menu alternatives to choose between: NIGHT ACTIVATE CHANGE RESET The personal program...
  • Page 14 Language LANGUAGE You can choose between several languages; the factory setting is English. Set the required language by scrolling through them using the button and conirm with You can also use the shortcuts in the display mode (press for three seconds). Then you go directly to the language menu.
  • Page 15 Ventilation mode VENT If the room temperature sinks by more than 3°C in a minute, for example, when airing, ventilation mode is activated. The thermostat then deactivates heating for 15 minutes, after which it returns to the same setting; ventilation mode shows in the display when it is activated.
  • Page 16 Reset the operation mode settings OP MODE You can reset the settings in . All programs are reset and the OP MODE HEATING temperature and sensor settings return to the output values. Resetting does not afect the choice of or setting for OP MODE LANGUAGE DATE/TIME...
  • Page 17: Operation Mode Cooling

    Operation mode Cooling Operation mode Cooling is used in home, oice, storeroom environments and such like. In this operation mode, the thermostat works as a room thermostat for regulating air conditioning or other cooling within a temperature range of +5°C to +45°C. Energy saving programs are primarily adapted for home and oice environments but can also be used for cooling, for example, storerooms.
  • Page 18 The programs are in the under . To change program, browse MAIN MENU PROGRAM using and select using . The manual program is the factory setting, i.e. you set the required temperature (set point) and the thermostat maintains that temperature. Program for home environment HOME The temperature is raised by 5°C at the following times:...
  • Page 19 ACTIVATE The program is started with , and from there you can choose to use ACTIVATE TIMER . If you want to start the program without the timer function, select SETTING the program will then be active until another program is started. If you select the program will remain active for the selected time and will then return to the previously used program.
  • Page 20: System Setting Menu

    (Saturday and Sunday) or the whole week. It is normally easiest to set the whole week irst and then adjust this for the days requiring a diferent setting. When you have decided on the day(s) the event shall be set for, set the time of day they shall occur at and the required room temperature at that time.
  • Page 21 Summer and winter settings are in the under ; select MAIN MENU SYSTEM S/W TIME Switch of the function under in the menu and select , a message is ON/OFF shown for a short time conirming that the function is switched of. Activate the function in the opposite way by selecting Sensor settings SENSOR...
  • Page 22 To see the total and momentary connection times, press when the thermostat is in display mode. The reset function is in the menu under ; from here, select SYSTEM RESET CONN TIME This is preset to and is changed to by pressing and conirming with Reset the operation mode settings...
  • Page 23: Operation Mode Industry

    Operation mode Industry Operation mode Industry is used to regulate the temperature of industrial processes, high temperatures or for the frost protection of sensitive installations. Temperatures within the ranges -15°C to +75°C and 0°C to +170°C can be regulated in this mode or the range can be limited to between -10°C and +15°C for frost protection purposes.
  • Page 24 Temperature hysteresis TEMP HYS The thermostat can be prevented from switching on and of the efect too often by increasing the temperature hysteresis. The hysteresis is the range the current value is permitted to deviate from the set point without the thermostat switching on or of the efect. A set hysteresis value of 0.3°C and a set point of 40.0°C means that the temperature (current value) can vary between 39.7 and 40.3°C.
  • Page 25: Program Menu

    PROGRAM Program menu To be able to measure the temperature as accurately as possible, there are two temperature ranges, one from -15°C to +75°C and one from 0°C to +170°C. There is also a frost protection program to enable sensitive installations to be safeguarded against frost in a simple manner.
  • Page 26: System Setting Menu

    SYSTEM System setting menu Under system settings, you will ind settings for, for example, language and date, as well as resetting functions for the time counter and for complete resetting to factory settings. The system settings are under in the SYSTEM MAIN MENU Language...
  • Page 27 Reset RESET There are three choices under the reset menu: CONN TIME OP MODE FAC SET The  RESET menu is under SYSTEM in the MAIN MENU Reset connection time CONN TIME The connection time is shown in hours; as with a vehicle trip meter, it shows the number of hours an installation has been connected for since it was last reset.
  • Page 28: Operation Mode Max/Min

    Operation mode Max/Min The Max/Min operating position is mainly used to keep roof and ground surfaces free of snow and ice. The temperature range is adjustable between -20°C and +10°C. For the best results and the best energy saving, combined temperature and humidity control should be used in the Max-/Min position, with associated Roof Sensor or Ground Sensor.
  • Page 29: Program Menu

    Set the required max temperature by pressing and conirm with then set the required min temperature in the say way. The values can be set with an accuracy of 0.5 degrees, and the factory settings are max +2°C and min -10°C. Both max and min temperatures can be set between +10°C and -20°C.
  • Page 30: System Setting Menu

    Example: You want snow melting to be deactivated between 22:00 and 04:00 and between 11:00 and 15:00 every day, i.e. the installation shall be active between 04:00–11:00 and 15:00–22:00. First select and then . The irst event WEEK 2 EVENTS at 04:00 and at 11:00.
  • Page 31 Temperature, A and B The thermostat uses external sensors that can be installed as . If there are two sensors installed, it is possible to switch between A & B Moisture sensor, C The thermostat uses moisture sensor C together with temperature sensor A. Delay +HEATING The delay can be set to ensure that the entire installation is free of snow and ice...
  • Page 32 Reset factory settings FAC SET The thermostat can be entirely reset to factory settings. All programmed data is deleted and the start up menu is opened. If you choose to reset the thermo- stat, it is important to know the operation mode it uses and the coniguration of the sensors.
  • Page 33: Fault Tracing

    Fault tracing Message Cause The sensor installed on terminal blocks 5 and 6 is not DISRUPTION ON SENSOR A correctly connected or is damaged. The sensor installed on terminal blocks 7 and 8 is not DISRUPTION ON SENSOR B correctly connected or is damaged. The sensor installed on terminal blocks 5 and 6 is not SHORT CIRCUIT ON correctly connected or is damaged.
  • Page 34: Technical Data

    Technical data Voltage 230VAC +/- 10% ~ 50Hz Break-of capacity 3680W/16A/230VAC Power consumption 2.5 W Application range -15°C to +170°C divided into two ranges Low temperature range -15°C to +75°C – Sensor type NTC High temperature range 0°C to +170°C – Sensor type PTC Roof sensor, moisture 24 VDC, NO Connection cable...

Table of Contents