Download Print this page

Sealey HVF20S.V2 Quick Start Manual page 2

20” industrial high velocity orbital drum fan

Advertisement

3. SPECIFICATION
Model No:........................................................... HVF20S.V2
Current: ...........................................................................0.5A
Fan Diameter: .................................................. Ø550mm(20")
Maximum Airflow: .................................. 115mᶾ/min(4061cfm)
Power: ........................................................................... 110W
Speed Range: ................................................. 1100-1350rpm
Speeds: ................................................................................ 3
Supply: ...........................................................................230V
4. WALL MOUNTING
4.1.
This item may be wall mounted using the supplied Wall Mounting Kit. See Steps 1 to 4 below.
1 - Fixing the hook to the wall
2 - Mount frame to hooks
5. OPERATION
WARNING! Ensure that you read, understand and apply safety instructions in Section 1 before using fan.
5.1.
Check that the speed control is set to "0" (off) and then plug into the mains power supply and switch the power on.
5.2.
The fan features 3 speeds which are selectable using the switch located on the back of the fan.
5.3.
Adjust the direction of the air flow by rotating and tilting the fan up or down as required.
5.4.
When you have finished using the fan ensure you turn the speed control switch to "0" (off) , disconnect the fan from the power supply.
6. MAINTENANCE
WARNING! Ensure that the fan is disconnected from the mains power supply before attempting any of the following:
6.1.
Use a soft, damp cloth to clean the fan. DO NOT immerse the fan in water and never allow water to drip onto the motor housing. DO
NOT use solvents, petroleum, paint thinner or other chemicals to clean the fan.
6.2.
To clean the fan blade, undo the cross headed screws around the circumference, remove the grille and clean the blade with a slightly
damp cloth. Replace the grille as required and refit the cross headed screws.
6.3.
Should the motor, switch or the power lead require service or maintenance contact your local Sealey service agent.
6.4.
When not in use place the fan in its original box or otherwise cover to protect from dust, and store in a safe, dry, childproof location.
© Jack Sealey Limited
Concrete
Wood
3 - Clamp frame to hooks
Original Language Version
Concrete
Wood
4 - Fasten frame to wall
using wire rope
HVF20S.V2 Issue 1 29/04/2020