Lynteck ES73 Quick Start Manual

Motion sensor bulkhead light

Advertisement

Quick Links

ES73
MOTION SENSOR
BULKHEAD LIGHT
Lamp Shade
PIR Motion Sensor
ƒ
Bulb Holder
Bottom Housing

INTRODUCTION

Your EVERSPRING MOTION SENSOR BULKHEAD LIGHT i s a
unique lighting system with the capability of controlling additional
lighting for your home or business. At night, the built-in passive
infrared (PIR) motion sensor turns on the floodlight when it detects
motion in its coverage area. During the day, the built-in photocell
sensor saves electricity by deactivating the floodlight. An
adjustable timer lets you select how long the light will stay on after
activation. Sensitivity adjustment lets you change the detection
distance according to the temperature. Two operation options let
you choose: Automatic Operation or Manual Override.
Note: Read this entire manual before you start to
install the system.

SAFETY PRECAUTIONS

l
Do not install when it is raining.
l
Be sure to switch off power source before installing.
l
Make sure that the power wiring comes from circuit with an
external 16A miniature circuit breaker for the short circuit
protection or a suitable fuse.
l
Keep minimum 0.8m away from the lighted objects.
l
The unit can be installed only vertically (FIGURE 1a), not
horizontally (FIGURE 1b).
VERTICAL
FIGURE 1a & 1b
HORIZONTAL
IMPORTANT
Some local building codes may require installation of this product
by a qualified electrician.
Check your local codes as they apply to your situation. If the house
wiring is of aluminum, consult with an electrician about proper
wiring methods.
Maintenance or repairing work such as replacing current fuse shall
be done by a qualified electrician or technician.
Before proceeding with the installation, TURN OFF THE POWER
TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR
FUSE BOX TO AVOID ELECTRICAL SHOCK.

CHOOSING A MOUNTING LOCATION

l
For the best results, fix your motion sensor light on a solid
surface, 1.8~2.5M above the ground.
l
For outdoor installation, a location under eaves is
preferable.
l
Avoid aiming the motion sensor at pools, heating vents, air
conditioners or objects that may change temperature
rapidly.
l
Do not allow sunlight to fall directly on the front of unit.
l
Try to avoid pointing the unit at trees or shrubs or where the
motion of pets may be detected.
l
Prior to mounting, keep in mind that the motion sensor is
more sensitive to the motion, which is across the detection
field and less sensitive to the motion, which moves directly
towards the detector. (FIGURE 2)
SENSOR
LESS SENSITIVE
SENSITIVITY TO MOTION
FIGURE 2

BULB INSTALLATION

(1) Remove the lamp shade.
(2) Insert an incandescent or a PL bulb to the bulb holder by
turning clockwise.
(3) Do not use an incandescent bulb rated higher than 60W or
alternatively 13W for a PL bulb.

INSTALLATION

To facilitate installation, it is essential to get a drill and a
screwdriver ready. Select a location for the unit based on the
coverage angles shown in FIGURE 3.
FIGURE 3
SENSOR
MORE SENSITIVE
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES73 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lynteck ES73

  • Page 1 ES73 IMPORTANT Some local building codes may require installation of this product by a qualified electrician. MOTION SENSOR Check your local codes as they apply to your situation. If the house BULKHEAD LIGHT wiring is of aluminum, consult with an electrician about proper wiring methods.
  • Page 2 Install a wall switch adjacent to the power source. (FIGURE 4). This will help you operate this motion sensor light with ease. See OPERATION for further information. FIGURE 7a FIGURE 7b Connect the BROWN wire to terminal block “ L” mark. Connect the BLUE wire to terminal block “...
  • Page 3 SETTING THE LIGHTING SYSTEM (2) MANUAL OVERRIDE To keep the light on regardless of the motion, you can override (1) TEST MODE the Automatic Operation. Turn the wall switch off and on twice within 4 seconds. The interval between the first and second Make sure that the black label is stuck on photocell sensor operation must be within 0.5 - 2 seconds.

Table of Contents