Other Considerations - Prinsco HydroStor HS180 Design Manual

Table of Contents

Advertisement

9.0

Other Considerations

9.1
Impermeable Liners
In addition to functioning as an open bottom detention system or infiltrating retention system (into
the underlying soil), the HydroStor chamber system can be designed as a watertight system,
preventing stormwater from infiltrating into the subsurface. A watertight option may be desirable
in conditions where the groundwater is contaminated or underlying conditions could be impacted
by excess water infiltration. When it is not desirable for the water to infiltrate into the underlying
soil, a thermoplastic liner may be used to provide an impermeable barrier and prevent infiltration
into the subsurface.
Liners installed with HydroStor chamber system require proper installation in accordance with the
manufacturer's installation instructions. Contact your local Prinsco representative for more
information regarding the design and installation of liner systems for storm water applications with
HydroStor chamber systems.
Page 26
©2015 Prinsco, Inc | 800.992.1725 |
www.prinsco.com