STOVE GUARD
MBK19 - PGSGUARD
I N S TA L L AT I O N
A N D O P E R AT I N G
I N S T R U C T I O N S
1
INSTALLATION P. 4–13
For indoor use only.
Do not use in a professional kitchen.
The Control Unit must be installed
by an authorised electrician.
2
USER GUIDE P. 14–21
3
TECHNICAL SPECIFICATIONS
P. 22–24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MBK19-PGSGUARD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mobiak MBK19-PGSGUARD

  • Page 1 STOVE GUARD MBK19 - PGSGUARD I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S INSTALLATION P. 4–13 USER GUIDE P.
  • Page 2 There is a risk of explosion. The operating instructions, accessories and stickers must accompany the product. Follow the safety guidance for safe use of Stove Guard. If you have questions about the product, ask a specialist or refer to www.mobiak.gr...
  • Page 3: Table Of Contents

    P. 10-11 Installation of the Control Unit Function test USER GUIDE 14–21 Getting started with MOBIAK Stove Guard Read before using MOBIAK Stove Guard 16–17 Avoiding false alarms After alarm: Cookers with mechanical controls After alarm: Cookers with touch controls...
  • Page 4: Installation

    INSTALLATION Installing the Stove Guard To install correctly, follow the instructions. STEP 1: STEP 2: STEP 3: Installation of Installation of Function test the Heat Sensor the Control Unit p. 5–11 p. 12 p. 13...
  • Page 5: Installation Of The Heat Sensor

    INSTALLATION OF THE HEAT SENSOR The recommended place to install the Heat Sensor is directly above the centre of the cooker, under the cooker hood. The Heat Sensor can also be mounted on a wall with a mounting bracket or on the ceiling. Follow these instructions for correct installation.
  • Page 6 COOKER HOOD Measure distance Select the mounting location Mount the Heat Sensor Measure the installation height. The Heat Sensor should be centred If there is a metal mesh grease above the cooker, preferably within Zone 1 (see the diagram below). filter on the cooker hood, make It can be attached to the grease filter. It is important to ensure the sure it is greaseless and dry.
  • Page 7 I N S TA L L AT I O N U N D E R CO O k E R H O O D Allow the Heat Sensor to reach room temperature before use. The power to the cooker must be switched off (at the consumer unit). See the table below for the mounting location and follow instructions 1–4. Starting the Heat Sensor...
  • Page 8 WALL 80 cm Select the required location and mount the bracket Mount the Heat Sensor Wall mounting requires a bracket, sold separately. Press at least for a minute while The bracket is fastened on the wall using adhesive tape or screws. attaching adhesive.
  • Page 9 WA L L M o u n T I n g W I T H B R A C k E T Allow the Heat Sensor to reach room temperature before use. The power to the cooker must be switched off (at the consumer unit). See the table below for the mounting location and follow instructions 1–5.
  • Page 10 CEILING Measure distance Replace lens Finding the mounting Mount the Heat Sensor position Make sure that ceiling is grease- Carefully lift the lens with a screwdriver. Press down the less and dry. Press at least for a Measure the distance between IR lens extension (included) minute while attaching adhesive. the cooker and ceiling. Place the as shown in the picture.
  • Page 11 C E I L I n g M o u n T I n g W I T H I R L E N S E X T E N S I O N Allow the Heat Sensor to reach room temperature before use. The power to the cooker must be switched off (at the consumer unit). See the table...
  • Page 12: Installation Of The Control Unit

    CONTROL UNIT It is a statutory requirement that the Control Unit is installed by an authorized electrician. The power to the cooker must be disconnected throughout the entire installation. POWER Disconnect the power Switch off the power at the consumer unit. Do not turn on the Note! Consumer unit before the Heat...
  • Page 13: Function Test

    FUNCTION TEST The installation is completed when the test has been passed. The Heat Sensor will then give an alarm. This user manual, accessories and stickers should be left with the product for future reference. POWER Return the power...
  • Page 14: User Guide

    USER GUIDE...
  • Page 15: Getting Started With Mobiak Stove Guard

    GETTING STARTED The cooker is ready for use 15 minutes after completing the installation of the Stove Guard. However, at the beginning, it may start to signal during normal cooking. This is because the Heat Sensor learns what the normal temperature ranges are during cooking.
  • Page 16: Read Before Using Mobiak Stove Guard

    READ bEFORE Avoiding false alarms Use a pan that covers the entire hotplate to prevent false alarms. Using a lid is recommended. Always use the cooker hood if you have one. If you have a freestanding cooker or an oven under the hob, the oven controls must also be turned off once the power supply to the cooker or hob has been switched off by the alarm.
  • Page 17: Action In The Event Of An Alarm

    Action in the event of an alarm The cooker will automatically be ready for use after the Stove Guard has detected that the hazardous situation is over, and all the controls are set to “0”. See the alarm overview below for actions. SOUND MEANING MEASURES Heat Sensor Dislocation Alarm Return the Heat Sensor to the installation plate with the 4 “beeps” with a 1-second...
  • Page 18: Other Settings

    OTHER SETTINGS Change the sensitivity level Due to differences in kitchen environments, the sensitivity level of the Heat Sensor may have to be set manually. 1. Remove the Sensor from the installation plate The Heat Sensor emits 4 “beeps” ( ). The cooker is turned off. 2. Adjust the sensitivity level See pages 7-11 for sensivitity levels to be applied.
  • Page 19: Checking The Sensitivity Level

    Checking the Reset the Heat Sensor sensitivity level to factory settings 1. Remove the Sensor from the Remove the Sensor from the installation plate. (The Sensor installation plate. (The Sensor gives gives 4 “beeps” ( ) and the 4 “beeps” ( ) power is cut off cooker is switched off.) to the cooker). 2. Press and hold the button 1. Remove the battery lid. (approx. 10 sec.) until 2 “beeps” ) are heard. 2. Press the button once.
  • Page 20: Frequently Asked Questions

    FREQUENTLY ASKED QUESTIONS 1. I cannot turn on the cooker, and there is no malfunction of the Control Unit. Make sure that the Heat Sensor is firmly signal from the Control Unit ANSWER 2: The Heat Sensor has been removed or attached to the installation plate and that it is posi- ANSWER 1: tioned correctly. The LED shall be facing the user (see placed incorrectly on the installation plate.
  • Page 21 Auto-diagnostics. cooking, and should not give an alarm too easily. The test is recommended when retrofitting the Note! Therefore, the Stove Guard only emits an alarm when cooker and ceiling-mounted Heat Sensor. a certain temperature (or rate of temperature rise) is detected, but still long before a real risk situation.
  • Page 22: Technical Specifications

    TECHNICAL SPECIFICATIONS • Alarm signal 80 dB(A) @ 1 m • RF 433 MHz • Fulfils En 50615:2015 Standard for stove guards THE HEAT SENSOR Signal LED should face towards use IR lens (Lens extension for high installations) Button Battery lid (Battery 1 x CR2032) THE CONTROL UNIT THE JUNCTION bOX • Voltage 230 VAC • For safe connections up to 10 mm • Extremely low energy wires use (approx. 1 W) • Automatic electrical...
  • Page 23: Disposal

    Disposal Information about disposal of electrical and electronic waste (private households). Eu Directive 2012/19/EC on recycling of waste electrical and electronic equipment (WEEE) This symbol on the Stove Guard and associated documents means that this product should not be disposed of with normal household waste. For proper handling and recycling, this product must be delivered to a separate collection point where it will be accepted free of charge.
  • Page 24: Cooker Connection

    COOKER CONNECTION Alternative 1 Stove Guard's maximum supply current allowed is 32A and the appropriate diversity factor is 100%. The diversity factor applies to Stove guard Alternative 2 installations with parallel connected relays. Type 1, or equivalent circuit breaker (MCB) shall be used for protecting the Stove Guard supply. The circuit breaker shall have capability of interrupting the supply current within 100 ms at 4 x load. Designed and manufactured in the EU w w w .