IMPORTANT: The following information and instructions are to be used as a supplement to the KBVF Installation and Operation Manual (Part
No. A40288) until the new manual is available with the addition of Model KBVF-22D (Part No. 9572). The KBVF Series has been changed to
a second generation version (2G). The General Performance Specifications have not changed. This 2G version has an additional Frequency
Multiplier Jumper, a single Input Line Voltage Selection Jumper, and an additional connector for accessories. The KBVF manual must be read
and understood before attempting to operate this control. For further assistance, contact our Sales Department at 954-346-4900 or Toll Free
at 800-221-6570 (outside Florida).
Also see KBVF 2G Version Supplemental Connection Diagrams and Jumper Settings (Part No. A40090G).
Model
Part No.
KBVF-22D
9572
* CL Trimpot Range (Amps AC): 0.9 - 2.8 (Factory Setting: 2.4).
1
Setting Selectable Jumpers
This control has selectable jumpers which may have to be set before the control can be used. See Figure 1, above, for the location of
jumpers. WARNING! Disconnect the AC line before changing position of jumpers.
See Section III, on pages 14 - 16 of the manual.
1.1
AC Line Input Voltage Selection (Jumper J1 on Upper PC Board): This control can operate standard 208 - 230 Volt AC - 50/60
208/230 Volt AC line input (Jumper J1 in the "230V" position). To operate the control from a 115 Volt AC line input, set Jumper J1
to the "115V" position. See Figure 2, on page 2.
(A42137) - Rev. A00 - 10/26/2004 - Z3402A00
IRU 'XDO 9ROWDJH 0RGHO .%9)' 3DUW 1R 
Table 1 - Electrical Ratings
AC Line Input
Maximum
Volts AC
Current
(50/60 Hz)
(Amps AC)
115
6.0
208/230
3.8
Figure 1 - Mechanical Specifications (Inches/mm) and Control Layout
(Shown without Factory Installed Finger-Safe Cover)
12095 NW 39 Street, Coral Springs, FL 33065-2516
Telephone: 954-346-4900; Fax: 954-346-3377
This document is supplied with Model KBVF-22D (Part No. 9572).
Motor Output
Maximum
Voltage Range
Continuous Load Current
(Volts AC)
(RMS Amps/Phase)
0 - 230
Enlarged View of Jumpers and Trimpots
Maximum
Horsepower
(HP (kW))
1.5 *
¼ (.18)
Page 1 of 2

Advertisement

Table of Contents
loading

Summary of Contents for KB Electronic KBVF Series

  • Page 1 IMPORTANT: The following information and instructions are to be used as a supplement to the KBVF Installation and Operation Manual (Part No. A40288) until the new manual is available with the addition of Model KBVF-22D (Part No. 9572). The KBVF Series has been changed to a second generation version (2G).
  • Page 2 “The Right Control for Your Application.” 12095 NW 39 Street, Coral Springs, FL 33065-2516 KB Electronics, Inc. Telephone: 954-346-4900; Fax: 954-346-3377 .%9) ,QVWDOODWLRQ DQG 2SHUDWLRQ 0DQXDO 6XSSOHPHQWDO ,QIRUPDWLRQ IRU 'XDO 9ROWDJH 0RGHO .%9)' 3DUW 1R  WARNING! Do not change jumper position with the AC line connected. Be sure proper input voltage is applied to the control corresponding to jumper setting.
  • Page 3: Table Of Contents

    INSTALLATION OPERATING INSTRUCTIONS KBVF Adjustable Frequency Drive Variable Speed /Soft-Start AC Motor Control with I t Electronic Overload Protection for 3-Phase Induction Motors through 1 HP See Safety Warning on Page 3 This Manual Covers the Following Model Numbers KBVF-13, 23, 23D, 14, 24 and 24D The information contained in this manual is intended to be accurate.
  • Page 4: Simplified Setup And Operating Instructions

    SIMPLIFIED SETUP AND OPERATING INSTRUCTIONS IMPORTANT – You must read these simplified operating instructions before you proceed. These instructions are to be used as a reference only and are not intended to replace the detailed instructions provided herein. You must read the Safety Warning before proceeding. Be sure to read Important Application Information on page 7.
  • Page 5: Safety Warning

    SAFETY WARNING! — PLEASE READ CAREFULLY This product should be installed and serviced by a qualified technician, electrician or electrical maintenance person familiar with its operation and the hazards involved. Proper installation, which includes wiring, mounting in proper enclosure, fusing or other overcurrent protection and grounding, can reduce the chance of electric shocks, fires or explosion in this product or products used with this product, such as electric motors, switches, coils, solenoids and/or relays.
  • Page 6: General Performance Specifications

    TABLE 1 – GENERAL PERFORMANCE SPECIFICATIONS (All Models) Parameter Specification Factory Setting Recommended AC Line Input Operating Range (% of nominal 115/230 VAC) ±10 — Maximum Input Voltage Range, 115 VAC Models (VAC) 97 – 135 — Maximum Input Voltage Range, 230 VAC Models (VAC) 195 –...
  • Page 7: Important Application Information

    TABLE 2 – ELECTRICAL RATINGS Maximum Maximum Nominal Maximum Input Voltage Continuous AC Line KB Part Output Horsepower Model No. (VAC– 50/60 Hz) Output Load Input Voltage Rating Single Phase Current (RMS Current (VAC) HP, (KW) Amps/Phase) (Amps AC) KBVF-13 9957 0 –...
  • Page 8: Control Layout

    FIG. 3 – CONTROL LAYOUT Illustrates factory setting of jumpers and approximate setting of trimpots FIG. 4A – KBVF HP MECHANICAL SPECIFICATIONS – INCHES / [mm]...
  • Page 9 FIG. 4B – KBVF HP MECHANICAL SPECIFICATIONS – INCHES / [mm] FIG. 5A – KBVF 1 HP MECHANICAL SPECIFICATIONS – INCHES / [mm]...
  • Page 10: Jumper Settings

    FIG. 5B – KBVF 1 HP MECHANICAL SPECIFICATIONS – INCHES / [mm] III. JUMPER SETTINGS. A. Dual Voltage Controls – Models KBVF-23D and KBVF-24D have the capability of operating standard 208-230VAC - 50/60 Hz, 3-phase motors from either a 115VAC or 230VAC - 50/60 Hz AC line.
  • Page 11: Jumper (J1) Output Frequency Setting

    FIG. 7 – JUMPER (J1) OUTPUT FREQUENCY SETTING The control can also operate 60 Hz and 50/60 Hz motors (not 50 Hz motors) in an over speed mode. Note: In this mode, motor will produce full rated torque up to 60 Hz.
  • Page 12: Mounting

    IV. MOUNTING. Mount the control on a flat surface free of moisture, metal chips, and other contamination, including corrosive atmosphere, that may be harmful. For maximum cooling efficiency, mount the control with fins or sides in a vertical position. If controls are to be mounted in an enclosure, allow at least 6"...
  • Page 13: Forward-Stop-Reverse/Enable

    IMPORTANT - Do not bundle low voltage signal wiring (main speed potentiometer, signal following, manual start or forward-stop-reverse/enable) with any main power wiring from AC line or motor. For all signal wiring over 18" shielded cable is recommended. Do not ground (earth) shield. C.
  • Page 14: Fusing

    VI. FUSING. It is recommended that a fuse or circuit breaker be used on each AC line connection not at ground potential. Do not fuse neutral or ground connections. Use a normal or slow blow fuse according to the table below: TABLE 4 –...
  • Page 15: Trimpot Adjustments

    Controller Status Controller Status LED Color – Recovered Fault in Auto Mode in Manual Start Mode (Manual Mode) — Green Trip Trip Green Shutdown Trip — Shutdown Trip Red/Yellow/Green Shutdown Trip Red/Yellow/Green Shutdown Shutdown Green — — — (1) Slow flash: 1 sec. on, 1 sec. off; Quick flash: .25 sec. on, .25 sec. off. (2) When control recovers from CL or Stop, the Status LED returns to the “normal”...
  • Page 16 B. Maximum Speed (MAX). The MAX trimpot is used to set the FIG. 13B – MAX maximum output frequency of the drive. The maximum speed is factory set to full rated motor speed. Readjust the MAX trimpot as follows: 1. Rotate main potentiometer to maximum speed position (full clockwise).
  • Page 17: Cl Setpoint Vs Trip Time

    1. Connect an AC ammeter in series with one motor phase. 2. Lock motor shaft and quickly adjust desired locked rotor motor current using CL trimpot. Note: This adjustment must be made within 6 seconds or I t trip will occur. Example: A HP motor has a full load current of 1.8 amps.
  • Page 18: Limited Warranty

    If more precise speed regulation is required due to varying load, the boost can be set as follows: 1. Place an AC analog RMS ammeter in series with one motor lead. (Generally, digital or clamp-on meters do not yield accurate readings. 2.

This manual is also suitable for:

Kbvf-22d9572

Table of Contents