Table of Contents

Advertisement

Quick Links

OPERATION MANUAL
Device type
Manufacturer
Version / date
Technical editing
Operation Manual HELIO-STROB tripLED
HELIO-STROB tripLED
ELMED Dr. Ing. Mense GmbH
Weilenburgstr. 39
D-42579 Heiligenhaus
Germany
Phone.: +49 2056 / 9329-0
Fax:
+49 2056 / 9329-33
E-mail: helio-strob@elmedgmbh.com
Web:
www.elmedgmbh.com
Version 2.2 / 14.01.2020
M. Stolte / C. Mense / Chr. Mundorf
© ELMED Dr. Ing. Mense GmbH.
All rights reserved.
Duplication, even in excerpts, is only permitted
with the written consent of the publisher.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the tripLED and is the answer not in the manual?

Questions and answers

Summary of Contents for HELIO-STROB tripLED

  • Page 1 Version 2.2 / 14.01.2020 Technical editing M. Stolte / C. Mense / Chr. Mundorf © ELMED Dr. Ing. Mense GmbH. All rights reserved. Duplication, even in excerpts, is only permitted with the written consent of the publisher. Operation Manual HELIO-STROB tripLED Page 1...
  • Page 2: Table Of Contents

    3.2.2 Connector pin assignment IN/OUT jack ..........18 3.2.3 Trigger output .................... 19 4. INTIAL STARTUP .................... 20 4.1 General information for putting into operation ......... 20 4.2 Electrical initial startup ................20 4.3 Operation ....................... 21 4.4 Functions ....................... 21 Page 2 Operation Manual HELIO-STROB tripLED...
  • Page 3 7.3 Connection / Operation / Charging ............. 43 7.3.1 Operating display ..................43 7.4 Maintenance ....................44 7.5 Waste disposal ....................44 7.6 Technical data ....................44 7.7 Description of symbols ................45 7.8 Final information ................... 45 Operation Manual HELIO-STROB tripLED Page 3...
  • Page 4: General Information

     quately instructed personnel that meet the requirements for a proper and in- tended use of the device. Safe operation cannot be assured if the HELIO-STROB tripLED is not used in  accordance with the above definition of appropriate use.
  • Page 5: Technical Terms Used

    1.2 Technical terms used 1.2.1 Explanations of terms The following explanations of terms are provided for a better under- standing of the functionality of the HELIO-STROB tripLED. Term Explanation triggering trigger impulses for the flash rate (internal / external) rising edge The flash tube flashes at a change in the trigger signal from “0”...
  • Page 6: Definitions

    – this responsibility can be transferred in part to other persons when required Page 6 Operation Manual HELIO-STROB tripLED...
  • Page 7: Design

    STROB tripLED devices. The devices are built according to the recognised European safety-related rules and correspond to the state of the art at the time of delivery. The basic construction of the HELIO-STROB tripLED includes the following com- ponents: Housing...
  • Page 8: Functional Description

    Display of system errors  Serial interface  1.6 Applied standards All HELIO-STROB tripLED devices are subject to extensive device safety and EMC testing, and bear the CE marking. They meet the requirements of the following regulations and directives: Directive 2004/108/EC (EMC) ...
  • Page 9: Declaration Of Conformity

    The attachments are part of this declaration. This declaration confirms compliance with the named directives, but does not include any warranties of characteristics in a legal sense. The safety information in the supplied product documentation must be observed. Operation Manual HELIO-STROB tripLED Page 9...
  • Page 10: Attachment To The Declaration Of Conformity

    Design engineering modifications that have such significant effects on the technical specifications and appropriate use de- fined in this operation manual so as to change the device considerably void the declaration of conformity! Page 10 Operation Manual HELIO-STROB tripLED...
  • Page 11: Measurement Units

    If you have questions about transportation or storage, please contact the manufacturer. The following ambient conditions must be met for storage: Temperature range -20 °C ... +50 °C  Air humidity no condensation  Thermal time constant < 10 K/h  Operation Manual HELIO-STROB tripLED Page 11...
  • Page 12: Delivery

    Immediately upon receipt, the delivery has to be inspected for integrity and completeness. Scope of delivery: The type and scope of delivery is documented on the enclosed delivery note. The standard scope of delivery consists of the following components: HELIO-STROB tripLED hand-held stroboscope  Mains unit / charger  Operation manual ...
  • Page 13: Safety-Related Information

    Contact the manufacturer if you have questions about safety. 2.2 User’s due diligence All HELIO-STROB tripLED devices were designed and built with due considera- tion of a hazard analysis and according to the carefully selected applicable har- monised standards, as well as other technical specifications. They meet the re- quirements of the Equipment Safety Act, which means they are state-of-the-art and guarantee the highest safety standards.
  • Page 14: Safety Symbols And Their Meaning

    This symbol indicates important information in the operation manual that must be strictly observed. This symbol warns he user against staring into the light source. This symbol indicates information provided for improving the under- standing of processes. Page 14 Operation Manual HELIO-STROB tripLED...
  • Page 15: Basic Safety Measures

    These persons must have read and understood the opera- tion manual, in particular the section “SAFETY-RELATED INFORMATION”, and then act accordingly. They must have been instructed in the basic principles of health and safety at work and accident prevention. Operation Manual HELIO-STROB tripLED Page 15...
  • Page 16: Help With Safety-Related Questions

    2.7.2 Epileptics In case of users with a neurological proneness to epileptic sei- zures, the light effects produced by a stroboscope may cause photo- induced epilepsy. Users with such predisposition must not use strobo- scopes! Page 16 Operation Manual HELIO-STROB tripLED...
  • Page 17: Technical Data / Inputs & Outputs

    Light intensity max. 5500 Lux (distance: 50 cm) Accuracy 0.01 % ± 1 digit Operating temperature 0° ... +40° C Storage temperature -20° ... +50° C Air humidity 80% relative air humidity at 30° C Operation Manual HELIO-STROB tripLED Page 17...
  • Page 18: Inputs / Outputs

    3.2.1 Connector pin assignment POWER jack Jack Description BATT - BATT + AUX + AUX – 3.2.2 Connector pin assignment IN/OUT jack Jack Description 0 V (ground) +5 VDC (output) +12 VDC (output) Trigger OUT Trigger IN Page 18 Operation Manual HELIO-STROB tripLED...
  • Page 19: Trigger Output

    3.2.3 Trigger output The HELIO STROB tripLED is equipped with a trigger output (Trigger OUT), for example to control other devices. The signal on the IN/OUT jack depends on the TTL level. The period duration depends on the flash rate; T is constant (200 µs).
  • Page 20: Intial Startup

    Do not use any parts that have been damaged! 4.2 Electrical initial startup On / Off switch Display / touch panel USB jack Twist knob IN/OUT jack POWER jack Page 20 Operation Manual HELIO-STROB tripLED...
  • Page 21: Operation

    An additional value in smaller numbers is shown on the bottom row of the display – when adjusting the frequency for example, the current phase shift value is shown in addition. Touch panel Twist knob Touch Turn Operation Manual HELIO-STROB tripLED Page 21...
  • Page 22: Buttons Of The Touch Panel

    Trigger mode selection: External status, rising edge Trigger mode selection: External status, falling edge Internal triggering External triggering, rising edge External triggering, falling edge Battery operation / battery charge level Mains operation / battery charging Twist knob Page 22 Operation Manual HELIO-STROB tripLED...
  • Page 23: Adjusting The Frequency

    (for example half) the frequency. For checking the determined value in the INTERNAL trigger mode use the function by means of which the flash rate can be multiplied in integer numbers: Operation Manual HELIO-STROB tripLED Page 23...
  • Page 24 Factor to increase the flash rate (max. 10 times) Factor to reduce the flash rate Return to original frequency Accept determined frequency in the second row of the display indicates that you cannot fur- ther increase the frequency using the multiplier Page 24 Operation Manual HELIO-STROB tripLED...
  • Page 25: Phase Shift

    If a delay in milliseconds is set, corresponding to a phase shift greater than 540°, a corresponding notice appears in the second line of the display alternating with the standard message (see illustration). Operation Manual HELIO-STROB tripLED Page 25...
  • Page 26: Slow Motion

    The entire periodic movement sequence of a test object can be ob- served with the help of slow motion. It creates the impression that the object is moving slowly and continuously. Select the speed and movement direction between +5 Hz and -5 Hz (beat frequency). Page 26 Operation Manual HELIO-STROB tripLED...
  • Page 27: Transformation Ratio

    With the “Transformation Ratio” function it is for example possible to use the trigger signal of a transducer on the motor axis in order to ob- tain a still image of a shaft connected via a transmission. Operation Manual HELIO-STROB tripLED Page 27...
  • Page 28: Triggering

    “-.--”. With external signals > 0 Hz, the stroboscope flashes at the external clock. Frequencies > 845 Hz to 8000 Hz are integrally di- vided. The undivided frequency of the external clock is shown on the display. Page 28 Operation Manual HELIO-STROB tripLED...
  • Page 29: Internal Triggering

    4.4.6.2 External triggering, rising edge Select the triggering mode Select the option “External triggering, rising edge” Confirm input 4.4.6.3 External triggering, falling edge Select the triggering mode Select the option “External triggering, falling edge” Confirm input Operation Manual HELIO-STROB tripLED Page 29...
  • Page 30: Flash Duration (Button "Duration")

    Since the two modes work independently of each other, the active (se- lected) mode is shown inverted. Max. flash duration depending on the frequency Speed / min 6000 12000 18000 24000 30000 36000 42000 48000 Frequency / Hz Page 30 Operation Manual HELIO-STROB tripLED...
  • Page 31: Flash Duration, Degrees

    4.4.7.1 Flash duration, degrees Select Duration mode (flash duration) Select the option “Degrees” Set value Confirm input 4.4.7.2 Flash duration, microsecond Select Duration mode (flash duration) Select the option “Microsecond” Set value Confirm input Operation Manual HELIO-STROB tripLED Page 31...
  • Page 32: Touch Panel Calibration

    5 seconds. Finished! 4.6 Serial interface Via the serial interface, the HELIO-STROB tripLED can be computer-controlled. It is also possible to update the firmware via the serial interface. Further information on controlling via PC and firmware updating can be found on our Internet service page.
  • Page 33: Power Supply

    At a flash rate of 50 Hz and a flash duration of 50 µs, the HELIO-STROB tripLED can be operated on battery for approximately 8 hours. Continuing to use the strobo- scope is possible even when the battery is drained.
  • Page 34: Replacing The Battery

    Using non-specified batteries is associated with the following hazards: Electrical hazard  Fire hazard  Explosion hazard  Used batteries have to be disposed of according to the applicable le- gal regulations. Page 34 Operation Manual HELIO-STROB tripLED...
  • Page 35: Maintenance

    5. MAINTENANCE 5.1 Maintenance According to the design, the HELIO-STROB tripLED is not susceptible to disturb- ance. However, the following should be generally observed: Do not throw the device or expose it to heavy impacts.  Store the device protected from damage.
  • Page 36: Inspection / Calibration

    To maintain the reliability and the high quality standard of the HELIO-STROB tripLED over a long period of time, the device should be inspected by the manu- facturer on a regular basis. All device-specific functions are checked in the course of maintenance.
  • Page 37: Replacement Parts / Accessories

    Item no. Designation 0365100052 Handle 0310610050 5-pin plug (triggering IN / OUT) 0310210012 Mains unit / charger for HELIO-STROB tripLED 0310210180 Replacement battery for HELIO-STROB tripLED 0310200070 USB connection cable, A/St – B/St, length 1.8 m 0310550020 Transport box Operation Manual HELIO-STROB tripLED...
  • Page 38: Drawings

    6. DRAWINGS 6.1 Markings on the housing Page 38 Operation Manual HELIO-STROB tripLED...
  • Page 39: Operation Manual For Mains Unit / Charger

    If you have any questions, please contact the manufacturer. The switched mode EGSTON mains unit / charger is microprocessor controlled and programmed to work with the HELIO-STROB tripLED. 7.2 Safety-related information 7.2.1 Safety symbols and their meaning...
  • Page 40: Safety Instructions

    Egston mains unit / charger. Warming of the housing during operation is normal and harmless. While in operation the charger must not be covered or operated near radiators or in direct sun light. Page 40 Operation Manual HELIO-STROB tripLED...
  • Page 41 Adverse environmental conditions are: high humidity level  (> 95% relative humidity, condensing) moisture  dust and flammable gases, vapours or solvents, gasoline fuel  excessive ambient temperatures (> +40° C, > +104° F)  Operation Manual HELIO-STROB tripLED Page 41...
  • Page 42 Please take care that defective / not chargeable and used up (old)  batteries are hazardous waste material and that these must be disposed of according to national regulations. Please always consider the safety instructions.  Page 42 Operation Manual HELIO-STROB tripLED...
  • Page 43: Connection / Operation / Charging

     Egston mains unit / charger. The automatic mains supply starts when the HE- LIO-STROB tripLED is switched on. At the same time the built-in battery is charged. If the display is not lit, the contacts are possibly oxidised, the connecting ca- ...
  • Page 44: Maintenance

    7.6 Technical data INPUT: 100 – 240 V ~ / 50 – 60 Hz / 550 mA OUTPUT: 12.4 V /1.2 A Jack Description BATT - BATT + AUX + AUX – Page 44 Operation Manual HELIO-STROB tripLED...
  • Page 45: Description Of Symbols

    Revisions in the course of technical progress reserved. Manufacturer of the mains unit / charger: EGSTON System Electronics Eggenburg GmbH Grafenbergerstr. 37 A-3730 Eggenburg Austria © Copyright 2016 by Egston GmbH Version: April 2016 Operation Manual HELIO-STROB tripLED Page 45...
  • Page 46 _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ Page 46 Operation Manual HELIO-STROB tripLED...
  • Page 47 _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ Operation Manual HELIO-STROB tripLED Page 47...
  • Page 48 _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ Page 48 Operation Manual HELIO-STROB tripLED...

Table of Contents