Ecler essentials eMWR Quick Manual page 5

Table of Contents

Advertisement

Available languages

Available languages

Q
UICK
Operation
1. Adjust the volume to its minimum before turning on the transmitter. Then turn on the
receiver. LCD display will show the channel/frequency of the receiver. Press UP/DOWN button
to select the desired channel/frequency and press SET to confirm changes.
2. If a RF and/or AF strong level appears when the transmitter is off, change the channel in the
receiver to avoid interferences.
3. Turn on the transmitter. RF level meter shows the intensity of the received signal meanwhile
AF meter shows its audio amplitude. Adjust the volume according AF level meter. Check that
transmitter and receiver are in the same channel/frequency.
4. To link receiver and transmitter by means of an infrared signal, between emitter and
receiver, press SET button, the display will show PRG IR and after 2-3 seconds the receiver will
automatically link with the transmitter.
5. Press the POWER button for 2 or 3 seconds to turn off the receiver.
Keys functions:
o SET: menu selection and settings confirmation.
o UP & DOWN: parameters selection in the current menu. Hold for quick
frequency and channel selection.
Menus:
o CHANNEL/FREQUENCY: allows selecting the channel/frequency.
o PRG IR: allows linking receiver-transmitter by means of infrared frequency.
o SQUELCH: when the received signal strength falls below this threshold, the
output of the receiver is muted.
o DISPL: channel/frequency display.
o LOCK: LOCK ON mode prevents to accidentally change current work status.
LOCK OFF mode restores usual operation.