Brecknell RD65 User's & Technical Manual

Brecknell RD65 User's & Technical Manual

Hide thumbs Also See for RD65:

Advertisement

Quick Links

RD65
User/Technical
Manual
Contents subject to change without notice
Version 1.3
05/2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RD65 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Brecknell RD65

  • Page 1 RD65 User/Technical Manual Contents subject to change without notice Version 1.3 05/2016...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ....................1     General Information ........................... 1   Specifications ..............................1   Contents ................................1   Installation ......................2     Display Setup ......................4   3.1 Protocol Format Details ........................5   Connection and Wiring Details ..............9  ...
  • Page 3: Introduction

    -5° to 160°F (-20° to 70°C) Power Supply 11V-32V DC adaptor Waterproof IP65 Grade Contents  RD65 remote display  RS232 10m communication cable  DC24V 2.5A UL adaptor  2A fuse  Quick Guide & Technical Manual RD65 www.brecknellscales.com ...
  • Page 4: Installation

    1. Install the remote display through the hanging holes on wall with two M12 or 1/2” screws. (Hanging hole’s diameter is 13mm). Ensure secure mounting before proceeding. 2. Interface Light sensor Power Socket Communication Output Socket Config. Switch Compartment 2A Fuse RD65 www.brecknellscales.com  . 2 . ...
  • Page 5 See “Display Setup section”. (defaulted setting: Baud rate 9600, data form 8N1, Protocol format 3.1.5, Communication port RS232) 4. Attach power and communication cables. DO NOT power on until after completing step 4. RD65 www.brecknellscales.com  . 3 . ...
  • Page 6: Display Setup

    Format: 3.1.4 avail.) 19200 Format: 3.1.5 Bluetoo 38400 Format: 3.1.6 Position4 th (if 57600 Format: 3.1.7 avail.) 115200 Format: 3.1.8 Format: 3.1.9 Format: 3.1.10 Format: 3.1.11 Format: 3.1.12 Format: 3.1.13 Format: 3.1.14 Default dip switch settings in Bold RD65 www.brecknellscales.com  . 4 . ...
  • Page 7: Protocol Format Details

    3.1.3. Data Format Example: 123456lb, transmit data format of Weigh-Tronix WI125 models: <SP><G><SP><SP><1><2><3><4><5><6><SP><L><B><SP><CR><LF> Notes for symbols used in commands and response: <SP> Space <G/N> G = Gross, N = Net <LB/KG> LB or KG <CR> Carriage Return character <LF> Line Feed character RD65 www.brecknellscales.com  . 5 . ...
  • Page 8 3.1.6. Data format example: -9999lb, transmit data format: WI127 transmit data <SP><G><SP><1><0><0><0><0><0><SP><lb><CR><LF> <SP><G><-><9><9><9><9><9><SP><l><b><CR><LF> <SP><G><-><9><9><9><9><SP><l><b><CR><LF> Notes for symbols used in commands and response: <SP> Space (20hex) <G/N> G = Gross, N = Net <LB/KG> LB=lb, KG=kg <CR> Carriage Return character (0dhex) <LF> Line Feed character (0ahex) RD65 www.brecknellscales.com  . 6 . ...
  • Page 9 Notes for symbols used in commands and response: <STX> Start of Text ( 02hex) <SP> Space (20hex) <L/K> L = lb,K = kg <G/N> G = Gross, N = Net <CR> Carriage Return character (0dhex) <LF> Line Feed character (0ahex) RD65 www.brecknellscales.com  . 7 . ...
  • Page 10 Protocol Format Details (continued) 3.1.11. Data format example: 233233lb, transmit data format of 205/210: RD65 transmit commands : <ENQ> (05hex, Request weight from the indicator BI-Directional) Indicator Response: <SP><SP><2><3><3><2><3><3><lb><G><SP><SP><CR> Notes for symbols used in commands and response: <SP> Space (20hex) <kg/lb>...
  • Page 11: Connection And Wiring Details

    RS485 receive- Black 3 -------------------- RS485 transmit+ Yellow 4 -------------------- RS485 transmit- Green 5 -------------------- RD_AGND Blue 2. Symbols Defined:  :no communication Err01  :incorrect format data received Err02  :over range ¯¯¯¯¯  :below range _____ RD65 www.brecknellscales.com  . 9 . ...
  • Page 12: Troubleshooting

     Check cable connection cable communication) connected correctly  Format switch is not set correctly  Check the RD65 and Host Err02  Host is not set correctly (incorrect format protocols to make sure they  Unknown host or data format used on...