  • Page 3: Dear Owner

    Bedding and feeding $Dear Owner In buying a Kuhn machine you have chosen wisely. Into it have gone years of thought, research and improvement. You will find, as have thousands of owners all over the world, that you have the best that engineering skill and actual field testing can produce.
  • Page 4: Table Of Contents

    Simple weighing system T10 Bedding and feeding $Contents Dear Owner ........................1 Contents..........................2 Identification of the machine..................4 View of the terminal T10 ........................4 View of the module M10........................4 Manufacturers' marking ........................5 Optional equipment..........................5 Safety..........................6 Description of symbols used in this document................6 Safety instructions ...........................7...
  • Page 5 Simple weighing system T10 Bedding and feeding Functioning ........................18 Power on ............................18 Resetting to zero ..........................19 Net/Gross weighing mode ......................19 Setting the weighing unit display speed..................20 Resolution............................21 Error messages ..........................21 Optional equipment ..................... 22 Remote display..........................
  • Page 6: Identification Of The Machine

    Simple weighing system T10 Bedding and feeding $Weighing system identification 1. View of the terminal T10 2. View of the module M10 Weighing system identification...
  • Page 7: Manufacturers' Marking

    Please write below the type and serial number of the machine. This information is to be indicated to the dealer for all spare parts orders. The marking is on the card under the KUHN logo (1) visible from the outside. Type: Serial no.:...
  • Page 8: Safety

    Simple weighing system T10 Bedding and feeding $Safety 1. Description of symbols used in this document This symbol indicates a potentially hazardous situation that if not avoided, could result in serious bodily injury. This symbol is used to identify special instructions or procedures which, if not followed strictly, could result in machinery damage.
  • Page 9: Safety Instructions

    Never let anyone operate the machine who is not trained to do so. Should you have any difficulties in understanding certain parts in this manual, please contact your KUHN dealer. Precautions to be taken before carrying out any operations on the machine...
  • Page 10 Simple weighing system T10 Bedding and feeding Waste disposal Respect the environment! Never spill pollutants (oil, grease, filters, etc.) on the ground, never pour them down the drain and never discard them in any other place where they could pollute the environment. Never throw away or burn a tyre.
  • Page 11 Simple weighing system T10 Bedding and feeding Safety...
  • Page 12: Weighing System Characteristics

    Simple weighing system T10 Bedding and feeding $Weighing system characteristics 1. Description and glossary Terminal T10 Module M10 / M11 CAN wiring harness Weighing system characteristics...
  • Page 13: Technical Specifications

    • Voltage input: 12 V (10 V to 16 V) • Sealed aluminium box IP 64 • 35-pin connector CAN wiring harness - Allows the connection between the modules T10 and M10 / M11 • Connection to the battery • Connection to 3, 4 or 6 sensors •...
  • Page 14: Description Of The Controls

    Simple weighing system T10 Bedding and feeding 3. Description of the controls 1 key: • On / Off 2 key: • Setting to zero of the tare at the start (machine empty) • Incrementation of the figures 3 key: • Net/Gross •...
  • Page 15: Electrical Connection

    • A wiring harness (5) tractor side with a fuse and female connector. - Have your Kuhn dealer connect the wiring harness tractor side to the tractor battery terminals + (brown) and - (blue). - It is possible to have a second supply cable for another tractor under the reference A7040064.
  • Page 16 Simple weighing system T10 Bedding and feeding Connection diagram with display reminder (Optional equipment) - Connect cable Y (1) to terminals (2) and (3) and to the harness (4). - Place the display reminder (1) where you want it on the machine.
  • Page 17 Simple weighing system T10 Bedding and feeding Wiring diagram with battery Weighing system characteristics...
  • Page 18: Operating Conditions

    Simple weighing system T10 Bedding and feeding $Operating conditions 1. All machines When you start, before pressing zero, make sure that: • The machine is in the horizontal position • The machine is not exposed to violent winds • The transmission slides effortlessly •...
  • Page 19: Machines Without Chassis

    - On ALTOR 4560. 6070. 7560 ATHENOR 6070. 7560: • A green indicator, situated next to the T10 indicator, lights up when the axle is correctly positioned for weighing. In all cases: do not activate the brakes of the machine.
  • Page 20: Functioning

    Simple weighing system T10 Bedding and feeding $Functioning 1. Power on - Start up the module T10 by pressing on the button (1). • The message 'START' is displayed (Checking of the communication M10/M11/T10). • The message 'TEST' flashes (Sensor testing).
  • Page 21: Resetting To Zero

    - The message '--0--' is displayed then the message '0' is displayed going from right to left. - Release the two buttons. If the problem persists, call your Kuhn dealer. 3. Net/Gross weighing mode To load a new product, you can, at any time: - Carry out a temporary zero (Net weighing mode), press on the button (2).
  • Page 22: Setting The Weighing Unit Display Speed

    Simple weighing system T10 Bedding and feeding 4. Setting the weighing unit display speed The weighing unit display speed can be adjusted. - 6 display speeds are available: • High speed: 6 • Low speed: 1 - To go from one to the other: •...
  • Page 23: Resolution

    • Check the supply voltage. If the message 'CELL' is displayed: - The indicator signals a sensor problem: Contact your KUHN dealer so that he can check: • The condition of the sensors. • Their connections. • The correct operation of each sensor.
  • Page 24: Optional Equipment

    Simple weighing system T10 Bedding and feeding $Optional equipment 1. Remote display Transfer the weighing unit display to a second screen. 2. Battery Enables weighing unit operation without a tractor. Optional equipment...
  • Page 25: Maintenance And Storage

    Simple weighing system T10 Bedding and feeding $Maintenance and storage The weighing indicator does not require any particular maintenance, in the case of a breakdown or a malfunction call your KUHN repairman. When washing the machine, never point the water jet at the weighing indicator nor at the junction box.
  • Page 26: Limited Warranty

    - This Limited Warranty will not apply to any product that is altered or modified in any way without the express permission of the Company, or if parts not made by Kuhn are used on a machine sold by the Company and/or if repairs have been carried out by anyone other than Authorized Service Dealers.
  • Page 27 - The warranty claim is completed on line via extranet - www.kuhn.com or submitted on a KUHN warranty claim form and and returned to the Company within one month after the date of failure or the date of problem becoming apparent.

Table of Contents