ASBER GRE-400-20 General Instruction For Installation Use And Maintenance

ASBER GRE-400-20 General Instruction For Installation Use And Maintenance

Advertisement

General instruction for installation, use and maintenance
Models:
GRE-400-20
GRE-400-11
GRE-400-02
GRE-800-31
GRE-800-22
GRE-800-13
GRE-1200-42
GRE-1200-33
GRE-1200-24
GAS RANGES
GRE-400-20 T
GRE-400-11 T
GRE-400-02 T
GRE-800-31 T
GRE-800-22 T
GRE-800-13 T
GRE-1200-42 T
GRE-1200-33 T
GRE-1200-24 T
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GRE-400-20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ASBER GRE-400-20

  • Page 1 General instruction for installation, use and maintenance GAS RANGES Models: GRE-400-20 GRE-400-20 T GRE-400-11 GRE-400-11 T GRE-400-02 GRE-400-02 T GRE-800-31 GRE-800-31 T GRE-800-22 GRE-800-22 T GRE-800-13 GRE-800-13 T GRE-1200-42 GRE-1200-42 T GRE-1200-33 GRE-1200-33 T GRE-1200-24 GRE-1200-24 T...
  • Page 2: Table Of Contents

    “down to work”: the easy to understand graphical information replaced pages full of writing. Nevertheless, we recommend you thoroughly read this manual complied by ASBER’s kitchen supervisors, in order to benefit to the maximum from the multiple possibilities and advantages this appliance offers you.
  • Page 3: Instalation

    INSTALATION General and connection dimensions GRE-400-11 7,7kW 4,8kW GRE-400-11 T 7,7kW 4,8kW...
  • Page 4 GRE-800-13 7,7kW 4,8kW GRE-800-13 T 7,7kW 4,8kW...
  • Page 5 GRE-1200-24 7,7kW 4,8kW GRE-1200-24 T 7,7kW 4,8kW W – pointer VM – table tap valve G – gas inlet ½”...
  • Page 6 REGULATED LEGS Drawing 1 Drawing 2...
  • Page 7 Drawing 3 Drawing 4 1. OFF 2. PILOT POSITION 3. MAXIMUM 4. MINIMUM Drawing 5...
  • Page 8: Technical Specifications

    Technical specifications Table 1A Model GRE-400-20 GRE-400-11 GRE-400-02 Width Depth External [mm] dimension Height Height T model NET WEIGHT [kg] NET WEIGHT T models [kg] 4,5 kW Number of burners 7,5 kW 12,5 15,4 G-20/ G-30/ G-31 Power output kW/h...
  • Page 9 G-30/ G-31 kW/h 33,2 36,3 39,4 G-25 3,661 3,968 4,275 4,087 4,469 4,851 Nominal consumptions 2,880 3,121 3,363 [kg/h] 2,837 3,074 3,312 Air consumption Table 2 Air consumption Model. necessary for combustion GRE-400-20 GRE-400-11 GRE-400-02 GRE-800-31 GRE-800-22 GRE-800-13 GRE-1200-42 GRE-1200-33 GRE-1200-24...
  • Page 10 Injector diameter and adjustment Table 3 Burner 4,5kW Burner 7,5kW Pilot Family / Gas ø Injector ø Injector ø Injector Bypass Bypass (mm) (mm) (mm) (mm) (mm) (mm) (mm) G-20 1,50 Open Reg 1/5 turn 2,25 Reg 1/3 turn 0,40 G-25 1,50 Open Reg 1/5 turn...
  • Page 11: Positioning And Leveling

    Positioning and leveling  The positioning and gas installation should always be carried out by an AUTHORISED TECHNICIAN, observing the standards of each country.  It is advisable to install an extraction hood for the optimum operation of the appliance. ...
  • Page 12: Use

    Using the appliance Turning the burners on. a) Open the main general gas-tap installed on the outside of the appliance. b) Lightly press the control corresponding to the burner you want to ignite until it becomes unlocked and turn it anticlockwise to the PILOT position (Drawing 5), press this position again and light the pilot with a flame until it is stable.
  • Page 13: Environmental Protection Recommendation

    ENVIRONMENTAL PROTECTION RECOMMENDATION On ending its useful life, this product must not be thrown away in a standard rubbish bin, but must be left in an electrical waste and electronic equipment collection point for recycling. This is confirmed by the symbol on the product, user manual, or packaging. Depending on the symbol, the materials can be recycled.