Advertisement

USER MANUAL
®
A I R S U P P L Y
M V 6 0 0 - 2
by
CEGA
®
Innovations

Advertisement

Table of Contents
loading

Summary of Contents for CEGA Remuv MV600-2

  • Page 1 USER MANUAL ® A I R S U P P L Y M V 6 0 0 - 2 CEGA ® Innovations...
  • Page 3: Table Of Contents

    Table of Contents Symbol Reference Precautions & Intended Use Electromagnetic Immunity Parts Identification Product Specifications Transportation & Storage Operating the Air Supply MV600-2 Cleaning & Preventative Maintenance Filter Care Infection Control Returns & Repairs Internal Components Warranty Terms and Conditions 11-12 Patents &...
  • Page 4: Symbol Reference

    Symbol Reference REFER TO INSTRUCTION MANUAL/BOOKLET THIS END UP TYPE BF APPLIED PART TEMPERATURE LIMITATION ALTERNATING CURRENT HUMIDITY LIMITATION MANUFACTURER DATE OF MANUFACTURE KEEP DRY CAUTION ON (power) OFF (power) CLASS II NOT MADE WITH NATURAL RUBBER LATEX CHECK YOUR LOCAL/STATE/FEDERAL/ INTERNATIONAL GUIDELINES BEFORE DISPOSAL.
  • Page 5: Precautions & Intended Use

    3. Use this product only for its intended purpose as described in this manual and the REMUV™ or REMUV™ LP User Guide. Only use attachments and/or accessories that are authorized by CEGA Innovations®. 4. Route the power cord to avoid hazard.
  • Page 6 WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided due to risk of improper operation. If such operation is unavoidable, this equipment and the other equipment must be observed to verify that all equipment operates normally.
  • Page 7: Electromagnetic Immunity

    Electromagnetic Immunity The Air Supply MV600-2 is intended for use in the electromag- netic environment only as indicated below. 60601 EVEL MMUNITY OMPLIANCE EVEL ± 6 kV contact ± 6 kV contact Electrostatic Discharge (ESD) ± 8 kV air ± 8 kV air ±...
  • Page 8: Parts Identification

    Parts Identification Air Supply MV600-2 A. Power Switch B. Hose Connection C. Carry Handle D. Air Intake E. Power Cord F. Adapter...
  • Page 9: Product Specifications

    Product Specifications Dimensions: 15 x 10 x 9” (38 x 25 x 23 cm) Weight: 12 lbs (5.4 kg) Housing Material: Fire Retardant PP and PC Power Cord: 15 ft. (457 cm), 16 AWG, Hospital Grade Service Life: 5 years Power Input: 120V~, 60Hz, 10A Power Output: 1100-1200 Watts Air Flow Output: 3psi, 80 cfm...
  • Page 10: Operating The Air Supply Mv600-2

    Operating the Air Supply MV600-2 1. Ensure the power switch is in the off (o) position. 2. Plug the air supply into a 120VAC power outlet. 3. Connect the air supply hose to the REMUV™ Air Mat. 4. Turn the Power Switch at the top of the Air Supply MV600-2 to the on ( position (one power output with continuous flow).
  • Page 11: Filter Care

    Filter Care & Replacement Filter cleaning schedules are dependent upon the amount of use and the operating environment. The manufacturer recommends replacing the filter every year. Contact the manufacturer for further cleaning instructions. Infection Control If the Air Supply MV600-2 is used in a patient room where isolation protocols are being observed, the hospital should employ the same protocols/procedures for other equipment used in that patient room.
  • Page 12: Returns & Repairs

    Returns & Repairs CAUTION: NO USER SERVICEABLE PARTS. Only qualified service personnel are authorized to perform repairs on the Air System. (Replacement of power cord, air hose, and filter does not require qualified service personnel.) Units with damaged hoses or cords or any other physical damage should be taken out of service immediately.
  • Page 13: Warranty Terms And Conditions

    CEGA®. In all cases freight both ways will be at the expense of the customer. Equipment shall not be returned without advance notice to and consent of CEGA®.
  • Page 14 Notwithstanding any of the foregoing, a 90-day limited warranty is offered by CEGA® for the REMUV™ Air Mat and Skin Integrity Pad. In the event a REMUV™ Air Mat or Skin Integrity Pad fails due to a manufacturing or workmanship defect and the purchaser contacts CEGA®...
  • Page 15: Patents & Re-Order Information

    Patents In accordance with Section 287(a) of Title 35 of the United States Code, the reader is hereby placed on notice of CEGA Innovations’s rights in the United States Patents and Patents Pending for the REMUV™ Air Mat, Air Supply, Skin Integrity Pad, and Air Delivery System.
  • Page 16 CEGA ® Innovations CEGA Innovations , Inc. ® Sioux Falls, SD 57104 1-800-440-5605 cegaco.com © 2018 CEGA Innovations , Inc. ®...

Table of Contents