Installation and configuration manual
DULCOnvert
PROFIBUS
These operating instructions are only valid in conjunction with the "Operating instructions for the solenoid metering pump
delta
®
with controlled solenoid drive optoDrive
Sigma/ x Control type SxCb"!
The operator shall be liable for any damage caused by installation or operating errors.
982920
- PROFINET
®
®
DLTa" or the "Operating instructions for the motor-driven metering pump
Please carefully read these operating instructions before use. · Do not discard.
The latest version of the operating instructions are available on our homepage.
converter
®
EN
BA PM 008 02/18 EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DULCOnvert and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ProMinent DULCOnvert

  • Page 1 Installation and configuration manual DULCOnvert PROFIBUS - PROFINET converter ® ® These operating instructions are only valid in conjunction with the "Operating instructions for the solenoid metering pump delta ® with controlled solenoid drive optoDrive ® DLTa” or the “Operating instructions for the motor-driven metering pump Sigma/ x Control type SxCb”!
  • Page 2: Table Of Contents

    Operation................11 5.1 General............... 11 5.2 GSDML File..............11 5.3 Description of the data objects........11 5.4 Cyclic data transmission..........15 5.4.1 Overview of the data objects........15 5.4.2 Configure..............18 5.5 Extended diagnostics..........18 Technical data on DULCOnvert.......... 20...
  • Page 3: Prerequisites

    ® for the PROFIBUS ® module to work correctly. If it is not working, the LED on the PROFIBUS ® module flashes slowly red and green. The pump can then be extended with PROFINET ® functionality via the DULCOnvert converter.
  • Page 4: Setting Up Installation

    The software interrupts the set-up process in the event of pauses of longer than 60 s. 2.2 Setting up the PROFIBUS ® slave address Connect the disconnected DULCOnvert by its PROFIBUS ® cable to the pump’s PROFIBUS ® socket. [P] for 2 seconds on the pump.
  • Page 5: Profinet ® Settings

    If the pump is switched to another operating mode, it stops and can [Stop/Start] . only be restarted using 2.4 PROFINET ® settings Connect the DULCOnvert to its supply voltage. Connect the DULCOnvert to your PROFINET network - see ® “Installation” chapter. „Update accessible devices“ in the TIA portal under Select „Online accesses“...
  • Page 6 Setting up installation Assign a new name via „Online & diagnostics“ . Fig. 2 Continue configuring as usual. Description of the available objects - refer to “Operation” chapter.
  • Page 7: Special Features In Active Profibus ® Mode

    Special features in active PROFIBUS ® mode Special features in active PROFIBUS mode ® 3.1 General The pump cannot be manually set or programmed in PROFIBUS mode! To do this, set the PRO‐ ® FIBUS to „inactive“ . ® [i] to switch between the continuous displays at any Use button time, as in the other operating modes.
  • Page 8: Leds On The Profibus ® Module

    Special features in active PROFIBUS ® mode 3.3 LEDs on the PROFIBUS ® module LEDs Cause Flashing red and green at a Connection between the slow rhythm PROFIBUS ® module and pump has been disrupted; the hardware or software ver‐ sion of the pump is not suitable for PROFIBUS ®...
  • Page 9: Assembly And Electrical Installation

    ® There is no need for terminal resistors. C. Connecting the DULCOnvert to the mains voltage Connect the plug-in power unit of the DULCOnvert to the mains voltage. D. Installing the PROFINET ® cable Unscrew the housing screws and open the cover.
  • Page 10 Assembly and electrical installation E. Properly closing the housing CAUTION! Carefully close the housing otherwise the specific IP degree of protection will not be achieved. Check whether the sealing surfaces of the housing cover and the black seal of the lower part of the housing are free of dirt. Replace the housing cover onto the lower part of the housing and fasten in place with the screws.
  • Page 11: Operation

    Use the GSDML file to configure the master. It describes all fea‐ tures of the pump in PROFIBUS ® mode (keywords, diagnosis, modules, slots). The GSDML file can be downloaded from the www.prominent.com . The file name is clearly ProMinent website indicated: GSDML-V2.2-Hilscher-NL 51N- DPL-20170316-113214.xml 5.3 Description of the data objects...
  • Page 12 Operation Name Type Description 02 – Diag‐ 05 - Power‐ nose down Mode 00 – halt 03 –contact 01 – manual 04 - analog 02 – batch Error There are errors - see "Errors" Warnings There are warnings - see "Warnings"...
  • Page 13 Operation Name Type Description Start-Stop BYTE Corresponds to Start-Stop switch; if Start-Stop = 0, then the pump is stopped. Reset BYTE If the “Reset” value is switched from 1 to 0, the internal pump memory is deleted (e.g. with batch metering) and - as far as possible - existing errors are deleted.
  • Page 14 Operation Name Type Description Metering BYTE If a metering monitor is installed, it can be switched on (1). monitor Deactivation is (0). Concentra‐ FLOAT If the concentration calculation is activated on the pump, the tion current concentration can be read off here (delta ®...
  • Page 15: Cyclic Data Transmission

    Operation Name Type Description Overpressure Overpressure in the hydraulic system Low pressure Pressure too low in the hydraulic system Stroke UINT32 Counts the number of strokes since the last reset counter Delete stroke BYTE If the value changes from 1 to 0, the stroke counter is counter deleted Volume...
  • Page 16 Operation Module no. Output Length Input Length Module name Configuration identifier (hex) Remaining 4 bytes Remaining 40.83 strokes strokes External 2 bytes External 2 bytes Transmission C0,82,81 factor factor multiplier 1 byte External memory Stroke length 1 byte Stroke length 40.80 Metering 1 byte Flow Control...
  • Page 17 Operation Offset Value Type Name Area Module name Modul no. BYTE Delete stroke 0.1↓ Stroke counter number BYTE Delete quan‐ 0.1↓ Quantity tity counter Tab. 4: Pump data (input data) Offset Value Type Name Area Module name Modul no. high UINT32 Status Status...
  • Page 18: Configure

    Operation Offset Value Type Name Area Module name Modul no. high UINT32 Stroke Stroke 0..(2 counter number ↓ high FLOAT Volume ... (litre) Quantity counter ↓ high FLOAT Litres per ... (litre) stroke ↓ 5.4.2 Configure It is possible to select on the master which modules are to be involved in cyclic data transfer.
  • Page 19 Operation Service no. Error type (1st byte) Type of data access (2nd byte) (3rd byte) No. – see Table 2 0x30 0x31 Date outside of limits 0x32 Date protected 0x34 Option not installed 0x35 Service not defined 0x36 Value cannot be changed 0x37 Update completed 0x55...
  • Page 20: Technical Data On Dulconvert

    Technical data on DULCOnvert Technical data on DULCOnvert Electrical data Supply voltage: 230 V AC Degree of protection Degree of protection: IP66 * * with professional installation Dimensions PROFIBUS cable, length: Plug-in power unit, length: 1.5 m Housing, HxWxD: 140x110x60 mm *...
  • Page 24 ProMinent GmbH Im Schuhmachergewann 5-11 69123 Heidelberg, Germany Germany Telephone: +49 6221 842-0 Fax: +49 6221 842-419 Email: info@prominent.com Internet: www.prominent.com 982920, 1, en_GB © 2017...