PRINTER INSTALLATION
OP-412T

OP-900 / OP-901 Indicator Parameter Settings

To enter calibration/parameter settings, follow the procedure below:
1.
Make sure the unit is set to either kg or lb
2.
Press and hold the HOLD and PRINT key at the same time for 2 seconds
3.
Navigate through the settings (C01 to C18) as shown in the table below by using the arrow keys and return keys as labeled under
each indicator button
4.
Press the PRINT
5.
Press the ACCUM key to save and exit settings at any time
Function
Communication
Setting
Baud Rate
25570 Rye Canyon Rd Unit H, Santa Clarita, CA 91355, United States
844-735-5386
key to enter/edit the parameter setting
Parameter
C18
C19
S E L L E T O N S C A L E S
INFO@SELLETONSCALES.COM
844.735.5386 | INFO@SELLETONSCALES.COM
HOW TO GUIDE
OP-412T-L1

Settings/Options

Set the serial interface data output method:
0 = Turn off serial interface data output
1 = Continuous sending mode, for remote display
2 = Print to paper thermal ticket printer (OP-412T)
3 = Command request mode, for computer.
4 = PC continuous sending mode, for computer
5 = PC/remote display, continuous sending mode
6 = Print to small label thermal printer (OP-412T-L1)
7 = Print to Zebra/large label thermal printer (OP-412T-L2)
8 = Reserved
0 = 1200 (for OP-910 remote display)
1 = 2400
2 = 4800
3 = 9600 (for all Printers and OP-910X, OP-910XL)
4 = 14400
WWW.SELLETONSCALES.COM
S E L L E T O N S C A L E S
25570 RYE CANYON RD, UNIT H
SANTA CLARITA, CA 91355
OP-412T-L2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OP-412T and is the answer not in the manual?

Questions and answers

Summary of Contents for SellEton Scales OP-412T

  • Page 1 Set the serial interface data output method: 0 = Turn off serial interface data output 1 = Continuous sending mode, for remote display 2 = Print to paper thermal ticket printer (OP-412T) Communication 3 = Command request mode, for computer.
  • Page 2 Set the serial interface data output method: 0 = Turn off serial interface data output Setting 1 = Continuous sending mode, connect computer 2 = Print mode, connect printer (OP-412T) 3 = Command request mode, connect computer Baud Rate 1 = 9600bit/s (OP-412T)

This manual is also suitable for:

Op-412t-l1Op-412t-l2

Table of Contents