  • Page 1 R2160 Thermal Imaging Camera White background Transparent background 1 AN 1 YEAR White Instruction Manual REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 2: Table Of Contents

    Adjusting Emissivity ................14 Enabling/Disabling Auto Power OFF ..........14 Setting the LCD Brightness .............. 14 Enabling/Disabling Temperature Bar ..........15 Setting the High/Low Alarm Values ..........15 Device Information ................15 continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 3: Introduction

    Product Disposal and Recycling .............. 18 Product Support ..................19 Introduction Thank you for purchasing your REED R2160 Thermal Imaging Camera. Please read the following instructions carefully before using your instrument. By following the steps outlined in this manual your meter will provide years of reliable service.
  • Page 4: Features

    In this case, press the button under the temperature measurement interface to "Calibrate" the sensor. Features • 160 x 120 infrared resolution (19,200 pixels) • 2.8" color TFT Display • Built-in LED flashlight • Choice of 5 color palettes • High and Low temperature spot and alarm indicators • Dustproof and 6.5' (2m) drop tested • Rechargeable li-ion battery • Tripod mountable for continuous long-term monitoring • View stored data with included software • Low battery indication and auto shut off REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 5: Included

    Temperature Range: 14 to 752°F (-10 to 400°C) Accuracy: ±3.6°F (2°C) or ±2% of reading Resolution: 0.1°F/°C Detector Specifications Detector Type: Uncooled microbolometer, Focal plane array (FPA) Spectral Range: 8 to 14μm IR Resolution: 160 x 120 (19,200 pixels) Image Presentation and Measurement Analysis Display: 2.8" color TFT Color Palettes: 5 (Iron/Rainbow/Gray/ Red-White/White-Blue) Center Spot: Emissivity: Adjustable (0.01 to 0.99) Temperature Alarm Indicators: High/Low (User adjustable) Automatic Hot/Cold Detection: Auto hot or cold spot-meter markers continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 6 Tripod Mountable: Low Battery Indicator: Power Supply: 3.7V/5000mAh rechargeable Li-ion battery Battery Life: Approx. 6 hours Charging System: In Camera Charge Time: 4 hours PC Connectivity: USB Cable (Type-C) Software: Yes (download from website) Software OS Compatibility: Windows 7/8/10 Supported Languages: English and French Product Certifications: CE, IP65, 6.5' (2m) drop test Operating Temperature: 32 to 122°F (0 to 50°C) Storage Temperature: -4 to 140°F (-20 to 60°C) Operating/Storage Humidity Range: 10 to 90% Maximum Operating Altitude: 6561' (2000m) Dimensions: 9.3 x 3 x 3.4" (236 x 76 x 86mm) Weight: 1lbs (454g) REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 7: Instrument Description

    12. SET Button 3. Trigger 13. UP Button 4. Micro SD Card Slot 14. Playback Button 5. USB Interface 15. BACK Button 6. Infrared Camera Lens 16. RIGHT Button 7. Interface Cover 17. DOWN Button 8. LCD Display 18. Tripod Mounting Hole 9. POWER Button REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 8: Display Description

    13. Date & Time 6. Color Palette Settings 7. High/Low Temperature Alarm Settings Power ON/OFF Press and hold the POWER button for 3 seconds to power on. To turn OFF, press the POWER button for 1 second. REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 9: Emissivity

    Plastics non film 0.95 Parquet floor 0.90 Tissue (fabric) 0.95 Laminate 0.90 Sand 0.90 PVC-Floor 0.92 Glass wool 0.90 Brick 0.93 Melted asphalt 0.93 Cliff 0.97 Screed/pavement 0.93 Roofing cardboard 0.93 Foamed polystyrene 0.94 Stucco 0.91 REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 10: Software Installation

    Software Installation Visit www.reedinstruments.com/software to download the R2160 software. Full specifications and Operating System compatibility can be found on the product page at www.reedinstruments.com. If you have specific questions related to your application and/or questions related to software setup and functionality please contact the nearest authorized distributor or Customer Service at info@reedinstruments.com or 1-877-849-2127.
  • Page 11: Switching The Unit Of Measure (°F/°C)

    For temperature tracking, press the SET button when highlighted to enable or disable this feature. Press the SET button to save your selection and return to the main menu. Press the SET button again to exit the main menu and resume normal operation. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 12: Color Palette Selection

    While in the main menu screen, press the SET button when is highlighted to enter advanced settings menu. Use the buttons to scroll through the following parameters. Once the appropriate parameter has been selected follow the associated instructions below. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 13: Setting The Language

    Press the SET button followed by the buttons to adjust the selected parameter. Press the SET button again to confirm selection. Repeat steps 2 through 4 for each required parameter. Press the button to exit the "Date & Time" function when complete and return to advanced settings. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 14: Adjusting Emissivity

    Press the SET button when "Brightness" is highlighted to enter the appropriate function. Press the buttons to select the desired brightness level between "Low", "Middle" or "High". Press the SET button to confirm selection. Press the button to exit the "LCD Brightness" function and return to advanced settings. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 15: Enabling/Disabling Temperature Bar

    Alarms" function and return to advanced settings. Device Information Press the SET button when "Device Info" is highlighted to view detailed information of the device. Press the button to exit the "Device Info" function and return to advanced settings. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 16: Factory Reset

    Press the SET button when "Auto Save" is highlighted to view detailed information of the device. Press the buttons to select between "Yes" or "No". Press the SET button to confirm selection. Press the button to exit the "Auto Save" function and return to advanced settings. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 17: Saving, Viewing & Deleting Images

    10. Press the SET button to confirm your selection. 11. Press the button to exit the saved pictures menu and resume normal operation. Figure B Applications • Home and Building Inspection • Plant and General Maintenance • Electrical and Mechanical Inspection • Predictive Maintenance • HVAC/R & Plumbing • Equine & Veterinary • Road Construction REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 18: Accessories And Replacement Parts

    REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one (1) year from date of shipment. During the warranty period, REED Instruments will repair or replace, at no charge, products or parts of a product that proves to be defective because of improper material or workmanship, under normal use and maintenance.
  • Page 19: Product Support

    Product Support If you have any questions on your product, please contact your authorized REED distributor or REED Instruments Customer Service by phone at 1-877-849-2127 or by email at info@reedinstruments.com. Please visit www.REEDINSTRUMENTS.com for the most up-to-date manuals, datasheets, product guides and software.
  • Page 20 TesT & MeasuRe wITh ConfIdenCe CheCk ouT ouR laTesT PRoduCTs! REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...

Table of Contents