INTRODUCTION
The STPA is a Telephone Page Adapter used to interface
Clarity mixer-amplifiers to Centrex lines, C. O. lines and
PABX stataion numbers. This instruction contains the
specifications and guidelines necessary to install, operate,
and maintain the STPA which is manufactured by Clarity,
1111 Industry Avenue, Roanoke, VA 24013.
This paging unit has received FCC type KX registration.
This Registration Number will be listed in the affidavits
filed with the telephone company; it will also be recorded
in the system log kept by installation and maintenance
personnel. The local telephone company is to be notified
of the FCC Registration Number and Ringer Equivalence
Number. FCC Registration Number: BAF9I7-13957-
OT-N; Ringer Equivalence Number: 1.1A. The STPA
connects to the telephone line by means of a standard jack
called the USOC RJ11C.
In accordance with FCC Rules with application tariffs,
the Page Adapter may only be installed with the
authorization of the owner of the host system.
DESIGN
General
The Clarity STPA Expandable Station Level Page
Adapter is designed to provide access to paging from a
standard PABX station number, a Centrex number, or a
Central Office line. The unit is directly connected to
Clarity mixer-amplifiers.
Adapters with mixer-amplifiers may be used to provide
multizone paging.
PABX Station Level Paging
NOTE: Before proposing Station Level Paging for your
PABX perform the following test:
1.
Dial between two stations on the PABX and
answer the call.
2.
Have the called party listen after the calling
TELEPHONE PAGE ADAPTER
Multiple Telephone Page
STPA
party hangs up.
3.
After calling party release, what does the called
party hear?
If the PABX IMMEDIATELY returns any type of tones
to the called party (dial tone, reorder tone, etc.) then
STATION LEVEL PAGING CAN NOT BE USED.
Consult your Clarity catalog for an appropriate trunk
level page adapter. If there is a delay of at least 10
SECONDS before any tones are returned, then one-way
paging may be used but talkback paging will be
impossible.
disconnect, then one-way or talkback paging may be
used.
If the type of paging you desire is possible on a station
level of your PABX, then continue in this section to
determine the equipment required.
1.
One Zone of One-Way Paging
This arrangement will require one PABX
station number, one STPA page adapter,
appropriate
speaker assemblies.
2.
Multi-Zone One-Way Paging with All Call
This arrangement will require a PABX station
number and STPA for each zone, and an
additional number and STPA for All Call.
Centrex or C. O. Line Access to Paging
1.
One Zone of One-Way Paging
One zone of one-way paging will require one
Centrex or C. O. Line, a STPA, and the
appropriate speakers.
2.
Multi-Zone One-Way Paging with All Call
This arrangement will require a PABX station
number and STPA for each zone, and an
additional number and STPA for all call.
SPECIFICATIONS
Applications
1
If the line REMAINS SILENT after
Clarity
mixer-amplifier,
CSP - STPA
Issue 3
and
947421

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STPA and is the answer not in the manual?

Questions and answers

Summary of Contents for Clarity STPA

  • Page 1 INTRODUCTION After calling party release, what does the called party hear? The STPA is a Telephone Page Adapter used to interface Clarity mixer-amplifiers to Centrex lines, C. O. lines and If the PABX IMMEDIATELY returns any type of tones PABX stataion numbers. This instruction contains the to the called party (dial tone, reorder tone, etc.) then...
  • Page 2: Installation

    - Each STPA, when connected to its own PABX station number, will provide one zone of paging. ALL CALL IN - Use a STPA and a station number per zone for multi- ZONE 2 IN 8 OHM OUT zone paging behind a PABX.
  • Page 3: Power Connections

    Indicator Punchdown POWER CONNECTIONS Block NOTE: Power is required for each STPA being used. If FIGURE 2 multiple units are being installed, power for additional LOCATION AND NUMBERING OF units may be multipled from pins 14 and 15 of a PUNCHDOWN BLOCK AND DIP SWITCHES preceding unit (pin 14 is "+"...
  • Page 4 B Battery (-24vdc) Music Source Tel Line PABX Station Number, (Optional) Input Centrex Number or B Ground (+) C. O. Line CLARITY Mixer/Amplifier Option switch on Clarity Mixer/Amplifier should be set to Tel Line Figure 5: One Zone One-Way Paging...
  • Page 5 Connect Ring of the station number to pin 17. zone one to pin 16 of the STPA being used for __ (c) Strap from pin 8 of the All Call STPA to pin 25 zone one. of each of the STPA's being used for individual (b) Connect Ring of the station number to pin zones.
  • Page 6: Operation

    This warranty is in lieu of and excludes all other warranties expressed or implied, and in no event shall Clarity be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product.
  • Page 7 WIRE TIE LOOP TO REMOVE COVER WIRE TIE USED TO BUNDLE WIRES LOOSEN SCREW, ENTERING AND LEAVING TERMINAL AREA THEN ACTIVATE LATCH WIREWAY OPENING TO WALL PLATE AND .155 DIA. HOLES FOR MOUNTING TO METAL WALL JUNCTION BOX SINGLE OR DOUBLE GANG JUNCTION BOX MOUNTING HOLE PATTERN MATCHES BOTH EURO PLATE...
  • Page 8 1. Red power reversal LED is lit. A. Reverse power connections to pins 29 and 30. 2. Will not trip ringing. A. Verify 24 vdc on pins 29 (+) and 30 (-). B. Verify ring voltage is present on pins 16 and 17 (75 vac min.) 3.