Remote Power supply system
210W specification RCS series
Charging unit        : RCS210-PB24
 
Power Supply unit : RCS240-AC1
Passive Head    
: RCS240PH
Active Head          : RCS240AH
Attention for Installation
 
(Read this section thoroughly before installation.)
Before  using  the  Remote  Sensor,  read  this  manual  carefully.
During installation and operation, pay close attention to the 
safety aspect.
◆ Please turn off the Remote System before any performances 
such as mounting, maintenance or breakdown.
◆ Ensure correct connections by reference to the wiring dia-
gram.
◆ To avoid malfunction caused by induction noise, cable 
should be kept apart from motor or other power cable.
◆ Work for a while or immediately after operation, please do 
not touch the (power supply unit, charging Unit, Head part) hot 
spots. Doing so could result in burns.
◆ This product, which is one of those high frequency utiliza-
tion equipment of Radio Law, Upon use You will need to install 
application. Please use it after you have made the application 
without fail. Installation details of the application procedure, 
see Telecommunications website of the Ministry of Internal  
Affairs and Communications, Please.
◆ This product has become a Japan national specification. It 
can not be used outside of Japan. It can not be used outside 
of japan. When used outside of Japan, I guess we assume any 
liability You.
Dimension
[Charging unit] RCS210-PB24
Specification
Charging unit
Type code
RCS210-PB24
Rated input voltage
Output voltage / current
Max30V / Max7A
Current consumption
Operating / Storage temperature
0 〜 40℃ /0 〜 50℃
Protection class
IP20
C o n n e c -
Power supply / signal
Round 3 pin / Round 5 pin
tion
Power
Terminal block
Battery connection(2-pole),Thermistor connection (2-pole),
Terminal width is 6.2 mm or less,Terminal screw size is M3.
Various signal connector
Refer to the following page "wiring." 
Cooling method
Natural air cooling
Protection circuit
Input overvoltage protection
Battery high temperature / low temperature protection
Battery not connected protection
Battery reverse connection protection
Accessories
Output cable (1.5m),  Thermistor with cable (1.5m),
External device communication connector, 4 screws M6x15
Parallel driving
None
Series driving
Avaiable
Signal output time required
Up in zone signal light from entering the head transmission area     ≦ 5s
To start charging from the in-zone signal lights     ≦ 5s
     
2017. 07. 26
  T313402He
System configuration
【Head】
Temperature control
[Thermistor]
RCS240PH
RCS240AH
24V
AC Power
【Power 
lead battery
【Charging unit】
  Supply  unit】
External 
RCS210-
External 
RCS240-
control 
control 
         PB24
           AC1
devices
devices
Power supply
(Wireless Power Supply)
Various signal transmission
Signal transmission
Various signal transmission
【Function of each component】
Power supply unit : I will convert to the high-frequency power supply, the 
AC power. Further, in response to the (power supply start signal) input 
signals, supplies a high frequency power to the Active head, and 
output control equipment in Zone signal and various signals Active 
head is received.
Charging unit : And is Charging to the battery. It regularly monitors the 
battery voltage and output voltage [battery monitor signal H, M, L] as 
the result.
Head : I can carry a variety of signal and power transmission in a 
non-contact.
※ Each cable, please 
【Connection diagram】
connect with the specified 
Output cable
length. 
You may receive an error 
(1) 24V lead battery
due to the output such as a 
decrease occurs.
Please refer to the 
[Mounting of the ferrite 
(2)
clamp]of the rear surface.
Thermistor with Cable
 
Charging unit
Power Supply  unit
(1) 
(1) 
External 
External device 
device com-
communication 
Power 
munication 
cable
cable
cable
(AWG24 〜 16)
(AWG28
         〜 16)
Passive 
Active Head
Head
(1)Parts  of  the  dotted  line  (External  device  communication  cable 
and 24V lead batteries) within the product is not included with this 
product. They are contents prepared and processed of a visitor.
(2)I have you use the attached article always, please paste it into 
the  top  portion  of  the  terminal  near  the  24V  lead  battery  thermis-
tor. In the case,please do not touch any terminals.
[Power Supply unit] RCS240-AC1
300
15
90
90
90
15
8-7X15
Power Supply  unit
RCS240-AC1
AC100V / AC200V
4A
0 〜 50℃ /0 〜 50℃
IP20
Round 3 pin / D-sub 9-pin
3P  inlet
Refer to the following page  wiring.  
Forced air cooling
Power cable (2m),  External device communication 
connector,  4 screws M6x15, One ferrite clamp
Dimension
[Passive Head] 
RCS240PH
Specification
Type code
Application charging unit / power supply unit
Rated gap
Distance
Center offset
Operating / Storage temperature
Protection class
Connection
Supply
(With  the  connector 
cable 1m)
Signal
Accessories
Wiring
● Charging side (RCS210-PB24)
① The output terminal for batteries 
② The terminal for thermistor
③ Input signal (voltage monitor request signal)
Other than at the time of charging, It is used when you want to output the batteries voltage monitor request signal.
Charging unit
Internal circuit
④ Output signal
Each output signal is open-collector. The maximum current value and the maximum output voltage, please connect so 
as not to exceed the maximum value by referring to the following values    .
Connect the load before doing so, please do not short-circuit the output signal.
80
1
〇 +
Charging unit
Internal circuit
〇−
<Input signal pin assignment>
Signal type
Input Voltage monitor request
O u t -
Voltage monitor signal H
Voltage monitor signal M
put
Voltage monitor signal L
Float charging signal
charging signal
Error signal
[Active Head] 
RCS240AH
Passive Head
Active Head
RCS240PH
RCS240AH
RCS210-PB24
RCS240-AC1
10mm
The sum total of gap of length and width is 10 mm or less. 
0 〜 50℃ /-10℃〜 50℃
IP65
Connected  to  the  Charging  unit  at  the  (fe-
Connected to the Charging unit at the (male) 
male) 3-pin round
3-pin round
Connected to the Charging unit at the (female) 
Connected  to  the  Charging  unit  at  the 
5-pin round
(male) D-sub9 pin
4 screws M6x15, One ferrite clamp
1234567891011121314
+
● Input current : 100mA
Vin
● Input voltage : 7.5V 〜 30V
7.5 〜 30V
Vcc
● Maximum load current : 5mA
Load
● Maximum load voltage: 24V
To fit each condition, 
please select the load
1
2
3
4
5
6
7
8
9
10 11 12 13 14
+ −
H
+
H
-
M
+
M
-
L
+
L
-
F
+
F
-
Pin 
Contents
number
1.2
It monitors the battery voltage and the voltage applied to this pin, and the output 
voltage monitor signal.
3.4
It is almost fully charged. (Charging aim:about 90%)  
5.6
If the charge has been reduced somewhat. (Charging aim:about 70%)
7.8
It needs charging for charging amount is reduced. (Charging aim:less than about 50%)
9.10
It turns on, when a charging current value turns into a rated value.
11.12
I will turn OFF during charging ON, in charge cut-off and float charging start.    
13.14
It turns on, if a battery error occurs. 
Wireless Power Supply by
(Former NIHON BALLUFF co., Ltd.)
Mail :b-plus-usa@b-plus-kk.com     Web:http://www.b-plus-kk.com
C
+
C
-
N
+
N
-

Advertisement

loading

Summary of Contents for B&PLUS RCS Series

  • Page 1 Remote System System configuration Dimension User's Guide 【Head】 Temperature control [Active Head]  [Passive Head]  [Thermistor] RCS240AH RCS240PH RCS240PH RCS240AH AC Power 【Power  Remote Power supply system lead battery 【Charging unit】   Supply  unit】 210W specification RCS series External  RCS210- External  RCS240- control  control           PB24            AC1 devices devices Power supply Charging unit        : RCS210-PB24 (Wireless Power Supply) Specification   Various signal transmission Power Supply unit : RCS240-AC1 Signal transmission Various signal transmission Passive Head Active Head Passive Head    ...
  • Page 2 Remote System Attachment Mounting og the ferrite clamp User's Guide ferrite clamp Power  supply  unit  and  Charging  unit,  in  order  to  obtain  a  フェライトクランプ Passive Head Active Head 受電ヘッ ド 給電ヘッ ド good  cooling  effect,  please  keep  as  shown  below  the  sepa- ● Power supply unit side (RCS240-AC1) ⑤ ② ration  distance  between  the  surrounding  body  so  as  not  to  block the airflow.

This manual is also suitable for:

Rcs210-pb24Rcs240-ac1Rcs240phRcs240ah