1. SAFETY INFORMATION ATTENTION This dehumidifier must not be used in rooms under the following conditions: - Potentially explosive atmosphere - Aggressive atmospheres - Featuring a high concentration of solvents - An extremely high ratio of dust Keep Children Away: Do not allow children to play with or around this unit, which could result in injury. Be sure the unit is inaccessible to children when not attended.
2. GENERAL ADVICE Before putting your dehumidifier into operation for the first time, the instructions manual should be studied carefully. After receiving the unit, you should check your dehumidifier for any transport damage. In case of damage, you should inform the sender immediately. Transport damages should be stated after unpacking the equipment.
5. OPERATING INSTRUCTIONS ATTENTION - Operate the dehumidifier only in the upright position. - Plug in to a standard outlet with the correct voltage and amperage for the unit. - Allow five minutes before restarting after the unit shuts off for any reason. This will avoid damaging the compressor.
6. ELECTRONIC CONTROLS This unit is equipped with an electronic control board. The meaning of each led and correspondent symbol on the control panel is the following: 1 On/Off switch 2 Humidistat – Set the desired humidity rate level 3 Hour counter – Counts the compressor’s working time 4 Run Mode –...
7. CONDENSATE OUTLET This dehumidifier is equipped with water collecting tank and with fittings for ” (14mm) hose. If working with a water collecting tank, the appliance will automatically switch off when full and the red light at the control panel (see page 6) will light up.
This dehumidifier can be operated within an ambient temperature range from +3 to +35°C and with a relative humidity from 35% to 90%. It is suitable for application on construction sites, residential buildings, museums, archives, garages and storage rooms. 12. SPECIFICATIONS ProDry TD 45 Dual ProDry TD 80 Dual Model Temperature Range +3 °C / +32 °C...
13. TROUBLESHOOTING Trouble Cause Solution Unit does not No power to the unit Plug in the unit; check power at outlet operate Switch not turned ON Turn ON the switch Completely filled water tank Water tank must be emptied and installed again Incorrect voltage selection Set the according to your electric supply source Main plug protective fuse broke...