FRIEDHELM LOH Rittal 3138.000 Assembly And Operating Instructions Manual

Roof-mounted fan

Advertisement

Quick Links

Montage-, Installations- und Bedienungsanleitung
Assembly and operating instructions
Notice d'emploi, d'installation et de montage
Montage-, installatie- en bedieningshandleiding
Montage-, installations- och bruksanvisning
Instrucciones de montaje, instalación y mando
Istruzioni di montaggio, installazione e uso
取扱説明書 ( 組立・設置および操作マニュアル )
Dachlüfter
Roof-mounted fan
Ventilateur de toit
Dakventilator
Takfläkt
Ventilador de techo
Ventilatore da tetto
ルーフ型ファン
3138.000
3140.110
3139.100
3140.140
3139.110
3140.500
3140.100
3140.510

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rittal 3138.000 and is the answer not in the manual?

Questions and answers

Summary of Contents for FRIEDHELM LOH Rittal 3138.000

  • Page 1 Dachlüfter Roof-mounted fan Ventilateur de toit Dakventilator Takfläkt Ventilador de techo Ventilatore da tetto ルーフ型ファン 3138.000 3140.110 3139.100 3140.140 3139.110 3140.500 3140.100 3140.510 Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Notice d’emploi, d’installation et de montage Montage-, installatie- en bedieningshandleiding Montage-, installations- och bruksanvisning Instrucciones de montaje, instalación y mando Istruzioni di montaggio, installazione e uso...
  • Page 2: Warning And Safety Notes

    Warning and safety notes Warning and safety notes Hinweis: Die Montage-, Installations- und Betriebsan- leitung ist auch als Download unter www.rittal.de verfügbar. Note: The assembly and operating instructions are available for downloading from www.rittal.com. Remarque : La notice d’emploi, d’installation et de mon- tage peut être téléchargée depuis le site www.rittal.fr.
  • Page 3: Table Of Contents

    Contents Contents Warning and safety notes ......2 Notes on documentation ....4 General information........4 CE label ............4 Storing the documents........4 Symbols used in these operating instructions 4 Other applicable documents ......4 Safety notes ........4 Product description ......
  • Page 4: Notes On Documentation

    1 Notes on documentation Notes on documentation Other applicable documents Assembly and operating instructions exist as paper doc- uments for the unit types described here and are en- General information closed with the equipment. These assembly instructions are aimed at We cannot accept any liability for damage associated –...
  • Page 5: Product Description

    3 Product description Product description Accessories 3139.1x0 3140.1x0 3140.5x0 Components Enclosure internal ■ ■ ■ thermostat 3110.000 Hygrostat ■ ■ ■ 3118.000 Digital enclosure ■ ■ ■ internal tempera- ture display and thermostat 3114.200 Speed control ■ ■* – 3120.200 Sensor for speed –...
  • Page 6: Scope Of Supply

    4 Installation Scope of supply 4.2.2 Layout of the electronic components in the enclosure The roof-mounted fan is supplied in a packaging unit in  Take note of the air flows from the internal fans of in- a fully assembled state and ready to connect. stalled electronic components.
  • Page 7: Installing The Roof-Mounted Fan

    4 Installation Installing the roof-mounted fan Rittal roof-mounted fan...
  • Page 8: Performing The Electrical Installation

    5 Performing the electrical installation Step 1 Note: Note: The side with the Rittal logo must be pointing towards the fan. The position of the roof-mounted fan in the mounting cut-out is freely selectable. It should be based on the position of the elec- Step 6 trical connection inside the enclosure.
  • Page 9: Installing The Pilot Wire

    5 Performing the electrical installation Note: Connection Function/assignment In accordance with NFPA 70 (NEC), only Power supply copper conductors must be used to connect the supply cable to the mains connector. Neutral conductor PE conductor +10 V Voltage output 10 V max. 1.1 A, galvanically isolated, not short circuit-protected 0…10 V/PWM...
  • Page 10: Commissioning

    6 Commissioning Inspection and maintenance The installed maintenance-free fan is mounted on ball bearings, protected against moisture and dust, and fit- ted with a temperature monitor. The life expectancy is at least 50,000 operating hours (L10, 40°C). The roof-mounted fan is therefore largely maintenance- free.
  • Page 11: Technical Specifications

    9 Technical specifications Technical specifications Unit 3138.000 3139.100 3139.110 3140.100 3140.110 3140.140 3140.500 3140.510 Electrical specifications 115, 1~, 60 380…415, 220…240, 115, 1~, 60 220…240, 220…240, 115, 1~, 60 Rated operating voltage V Without fan 3~,50/60 1~, 50/60 1~, 50/60 1~, 50/60 motor 400…480,...
  • Page 12 9 Technical specifications Unit 3138.000 3139.100 3139.110 3140.100 3140.110 3140.140 3140.500 3140.510 Operating temperature °C -20...+55 range Storage temperature °C -40...+70 range Protection category (to IP 21 (without filter mat and installation in accordance with section 4.3 “Installing the roof-mounted fan” – IEC 60 529) Installation for protection category IP 21) IP 21 (without filter mat and installation in accordance with section 4.3 "Installing the roof-mounted fan"...