■ Introduction
Only qualified personnel should work with the product.
Use the product correctly after thoroughly reading the section "Safety
precautions".
Should you require the inspection or repair of internal parts, contact the
Oriental Motor office where you purchased the product.
The product described in this manual has been designed and manufactured
for use in general industrial machinery, and must not be used for any other
purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused
through failure to observe this warning.
■ Standard and CE marking
Motors are recognized by UL and certified by VDE or DEMKO.
∗ Voluntary display of the CE mark conforming to the Low Voltage Directives.
Standards
UL 1004-1, UL 1004-3
CSA C22.2 No.100, CSA C22.2 No.77, EN 60950-1 or EN 62368-1
Standards File No.
UL File No. E64197, VDE, DEMKO
Applications for standard
EN 60034-1, EN 60034-5, EN 60664-1, EN 60950-1 or EN 62368-1
Temperature rise tests required by the standards are conducted in a state of
attaching a heat radiation plate.
The size, thickness and material of the heat radiation plates are as follows.
[Size] 200 × 200 mm (7.87 × 7.87 in.)
[Thickness] 5 mm (0.20 in.)
[Material] Aluminium alloy
Installation conditions
Overvoltage category
, Pollution degree 2, Class
When the machinery to which the motor is mounted requires overvoltage
category
and pollution degree 3 specifications, install the motor in a cabinet
that comply with IP54 and connect to power supply via an isolation transformer.
Standards for accessories
Capacitor : UL File No. E83671 (CYWT2),
VDE Licence No.112847 (for only capacitor rated voltage 250VAC types,
capacitor model ending in FAUL2),
VDE License No. 114747 (for capacitor rated voltage 450 VAC types)
Capacitor cap : UL File No. E56078 (YDTU2)
HM-9186-5
Lead Wire Type
equipment (For EN standards)
Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and safety
precautions.
• Please read it thoroughly to ensure safe operation.
• Always keep the manual where it is readily available.
Safety precautions
The precautions described below are intended to prevent danger or injury to
the user and other personnel through safe, correct use of the product. Use the
product only after carefully reading and fully understanding these instructions.
Handling the product without observing the
WARNING
instructions that accompany a "WARNING" symbol
may result in serious injury or death.
Handling the product without observing the
CAUTION
instructions that accompany a "CAUTION" symbol
may result in injury or property damage.
The items under this heading contain important
Note
handling instructions that the user should observe
to ensure safe use of the product.
• Do not use the product in explosive or corrosive environments, in the
presence of flammable gases, locations subjected to splashing water, or near
combustibles. Doing so may result in fire, electric shock or injury.
• Assign qualified personnel the task of installing, wiring, operating/ controlling,
inspecting and troubleshooting the product. Failure to do so may result in
fire, electric shock or injury.
• Do not transport, install the product, perform connections or inspections
when the power is on. Always turn the power off before carrying out these
operations. Failure to do so may result in electric shock.
• Turn off the power in the event the overheat protection device (thermal
protector) is triggered. Failure to do so may result in injury or damage to
equipment, since the motor will start abruptly when the overheat protection
device (thermal protector) is automatically reset.
• The motor is Class
equipment. Install the motor so as to avoid contact with
hands, or ground it to prevent the risk of electric shock. If the motor has a
protective ground terminal, be sure to connect the terminal to the ground.
Dieser Motor ist in Geräten mit Schutzklasse I zu verwenden. Der Motor ist
so einzusetzen, dass er nicht berührt werden kann, bzw. er ist zu erden, um
Stromschläge zu verhindern. Wenn der Motor über eine Schutzerdungsklemme
verfügt, ist die Erdung über diese vorzunehmen.
• Install the motor in an enclosures in order to prevent electric shock or injury.
• Keep the input-power voltage within the specification to avoid fire and
electric shock.
• Connect the cables securely according to the wiring diagram in order to
prevent fire and electric shock.
• Do not forcibly bend, pull or pinch the lead wires. Doing so may result in fire
and electric shock.
• Be sure to insulate the connection terminal of the capacitor. Failure to do so
may result in electric shock.
• Turn off the power in the event of a power failure, or the motor will suddenly
start when the power is restored and may cause injury or damage to equipment.
• Do not touch the connection terminal of the capacitor immediately after the
power is turned off (for a period of 30 seconds). The residual voltage may
cause electric shock.
• Do not disassemble or modify the motor. This may cause electric shock or injury.
WARNING
1

Advertisement

loading

Summary of Contents for Orientalmotor World K Series

  • Page 1 HM-9186-5 OPERATING MANUAL Thank you for purchasing an Oriental Motor product. World K Series Lead Wire Type This Operating Manual describes product handling procedures and safety precautions. Induction Motors and Reversible Motors • Please read it thoroughly to ensure safe operation.
  • Page 2 CAUTION Installation ■ Location for installation • Do not use the motor beyond its specifications, or electric shock, injury or The motor is designed and manufactured for installation in equipment. damage to equipment may result. • Do not touch the motor during operation or immediately after stopping. The Install it in a well-ventilated location that provides easy access for inspection.
  • Page 3 Connection and operation Time rating Insulate all the wire connections, such as the connection between the motor z Induction motors and the capacitor connection. Use the supplied capacitor cap to insulate the Induction motors have a continuous rating. capacitor terminal connection. z Reversible motors Reversible motors have a 30 minutes rating.
  • Page 4 Published in April 2020 • Please contact your nearest Oriental Motor o ce for further information. Technical Support Tel:(800)468-3982 Singapore 8:30 to 5:00 , P.S.T. (M-F) Tel:1800-8420280 A.M. P.M. www.orientalmotor.com.sg 7:30 to 5:00 , C.S.T. (M-F) A.M. P.M. www.orientalmotor.com Tel:1800-806161 www.orientalmotor.com.my Tel:+55-11-3266-6018 www.orientalmotor.com.br...

This manual is also suitable for: