Cx-12 Application Diagram For Apartment (Typical) - CAMDEN CX-12 Installation Instructions Manual

Switching network & bi-directional door sequencer
Table of Contents

Advertisement

12 - 24 V
AC/DC
Power
Electric Strike
MOV
Wire MOV
(supplied)
directly to strike
or magnet
RL1
RL2
DOR
DOO
DOR
LED
LED
RL1
RL2
RL2
CX-12
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
SCALE: NONE
Power
for Strike
DRAWING No: DRG-CX12-03a
Off / On
1
2
Door Operator
Camden Manufacturing
DRAWN BY: DGW

CX-12 Application Diagram for Apartment (typical)

Optional
Vestibule mounted
Convenience Switch
(Only active when
Lock relay energized)
Switch opens door
Interior Switch
Unlocks and
opens door
Apartment
Interphone
Panel
(powered signal)
Unlocks door only
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
DATE: 11/16/09
REVISED:
FILENAME:
CX_12 Diagram 3a.vsd

Advertisement

Table of Contents
loading

Table of Contents