  • Page 1 OWNER’S MANUAL PORTABLE ELECTROSTATIC PRECIPITATOR: SMOG-HOG ®...
  • Page 2 KNOW YOUR EQUIPMENT READ THIS MANUAL FIRST. Your Smog-Hog PCN should provide many years of trouble-free service. This manual ® will help you understand the operation of your PCN unit. It will also help you understand how to maintain it in order to achieve top performance. For quick future reference, fill in the unit information in the spaces below.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page SAFETY PRECAUTIONS ..................ii 1. INTRODUCTION ....................1 1.1 Description and Operation ................1 1.2 Electrical Characteristics ................1 1.3 Specifications ....................1 2. INSTALLATION ....................1 2.1. Packaging ..................... 1 2.2 Inspection Note ....................1 2.3 Installing the Extraction Arm Assembly ............1 3.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS We have provided many important safety messages in this manual on your Smog-Hog PCN. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word “DANGER”...
  • Page 5: Introduction

    Smog-Hog Revised 09/09 PCN Series Models 1. INTRODUCTION 2. INSTALLATION 1.1 DESCRIPTION AND OPERATION 2.1 PACKAGING The Smog-Hog PCN is a portable electronic air cleaner The Smog-Hog PCN is shipped in three containers. designed to eliminate particulate as it is generated. One consists of the main cabinet and operating components.
  • Page 6: Operating The Unit

    Smog-Hog Revised 09/09 PCN Series Models 1. Plug the unit into a grounded 115V/1/60 Hz electrical • The collecting pan should be emptied as required to receptacle. prevent overflow. 2. Lock wheel casters on unit to secure location. 4.2 COMPONENT CLEANING CAUTION 1.
  • Page 7: Other Maintenance

    Smog-Hog Revised 09/09 PCN Series Models 5. TROUBLESHOOTING GUIDE Tools Required 1. Screwdriver: 8˝ or longer with insulated handle. 2. Volt-Ohmmeter: used to check low voltage input (120 VAC) and continuity (OHMS). 3. High Voltage Probe: used to check high voltage power supply, minimum range from 0-15 KVDC.
  • Page 8: How To Check High Voltage

    Smog-Hog Revised 09/09 PCN Series Models Possible Cause: 1. Connect the ground wire on the handle of high voltage probe to the edge of the collection cell or a. The drive belt is loose or off the pulley. other convenient cabinet ground. b.
  • Page 9: Determining The Loss Of High Voltage

    Smog-Hog Revised 09/09 PCN Series Models 5.4 DETERMINING THE LOSS OF HIGH 5.5 CHECKING AIR MOVEMENT VOLTAGE (BLOWER AND DRIVE) As components build up dirt, the indicator light dims 1. If the unit has deficient airflow: then goes out at a point approximately 3.5KV cell a.
  • Page 10: Replacement Parts

    Smog-Hog Revised 09/09 PCN Series Models 6. REPLACEMENT PARTS 6.1 ORDERING PARTS Replacement parts can be ordered from your local representative or from UAS direct. To order parts from UAS, contact Customer Service at 1-800-252-4647. Please have the following information available for prompt service: 1.
  • Page 11: Troubleshooting Flowchart

    Smog-Hog Revised 09/09 PCN Series Models 7. TROUBLESHOOTING FLOWCHART...
  • Page 12: Pcn Parts List

    Smog-Hog Revised 09/09 PCN Series Models 8. PCN PARTS LIST Cabinet Assembly Diagram Item Part No. Description Quantity 37-0001 Insulator, Cell 37-0002 Insulator, Ionizer 36-0014 Spring, H.V. Contact 20-0467 Lamp (6 Volt) 20-0260 Lens Cover 20-0288 Power Cord 31-0017 Motor Pulley 31-0102 Blower Pulley 31-0083...
  • Page 13: Wiring Diagram

    Smog-Hog Revised 09/09 PCN Series Models 9. WIRING DIAGRAM Notes: 1. Must be U.L. recognized marking & labeling system for use on epoxy paint. 2. Label to be adhesive backed with black characters on white stock with clear plastic laminate. 3.
  • Page 14 Smog-Hog Revised 09/09 PCN Series Models This page intentionally left blank...
  • Page 15 Smog-Hog Revised 09/09 PCN Series Models This page intentionally left blank...
  • Page 16 UNITED AIR SPECIALISTS, INC. LIMITED WARRANTY UAS warrants to the original purchaser that all equipment will be free from defects in materials and workmanship for one year from the date of shipment from UAS (three years for Smokeeter® and VisionAir™ models other than CC and DC series) and that major structural components on SFC and MCB series will be free from defects in materials and workmanship for ten years from the date of shipment from UAS.