1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Do not use any sharp objects, acids or organic solvents for cleaning. Device can be
damaged.
Do not operate the device with sharp or pointed objects. The touch-sensitive surface
could be damaged.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
(1) Sensor buttons –/OK, +/¨
(2) Sensor buttons for operating functions
(3) Status LED
(4) Operation LED
3 Function
System information
This device is a product of the KNX system and complies with the KNX directives. Detailed
technical knowledge obtained in KNX training courses is a prerequisite to proper
understanding.
The function of this device depends upon the software. Detailed information on loadable
software and attainable functionality as well as the software itself can be obtained from the
manufacturer´s product database. Planning, installation and commissioning of the device are
carried out with the aid of KNX-certified software. The latest versions of product database and
the technical descriptions are available on our website.
32586901
97-09635-000
Figure 1
Seite 1/13
15.02.2013

Advertisement

loading
Need help?

Need help?

Do you have a question about the KNX Touch Glass sensor 2gang and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Berker KNX Touch Glass sensor 2gang

  • Page 1 Touch/Glass sensor 2gang / 3gang with room thermostat Glass sensor 2gang with room thermostat Order No. : 7564 20 xx Glass sensor 3gang with room thermostat Order No. : 7564 30 xx Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible.
  • Page 2: Operation

    Touch/Glass sensor 2gang / 3gang with room thermostat Intended use Operation of loads, e.g. light on/off, dimming, blinds up/down, brightness values, temperatures, calling up and saving light scenes, etc. Touch sensor: Installation in double flush-mounted appliance box according to DIN 49073 Glass sensor: Glass sensor TS: Installation in double installation socket for glass sensor (see chapter 6.3.
  • Page 3 Touch/Glass sensor 2gang / 3gang with room thermostat Figure 2 ą Operating mode Comfort Ć Operating mode Standby Operating mode Night ċ Operating mode Frost/heat protection š Display dewpoint operation; controller blocked ąg Comfort extension, night ąċ Comfort extension, frost protection ›...
  • Page 4 Touch/Glass sensor 2gang / 3gang with room thermostat When switched on, the display shows, next to the icon for the current operating mode, the current time and day the current room temperature the current exterior temperature the current setpoint temperature Changing the room temperature For short-term manual modification of the setpoint temperature.
  • Page 5 Touch/Glass sensor 2gang / 3gang with room thermostat Press the + and – sensor buttons simultaneously. The display shows the menu item CL60. i Pressing the sensor button ¨ opens the additional menu items in sequence. Setting the operating mode Figure 6 The main menu is displayed (Figure 5).
  • Page 6 Touch/Glass sensor 2gang / 3gang with room thermostat Figure 7 Press the sensor button ¨ to select the menu item Pro for Heating mode ĉ or Cooling mode Ċ and press the sensor button OK(Figure 7). Press the sensor button ¨ to select the required operating mode and press the OK sensor button.
  • Page 7 Touch/Glass sensor 2gang / 3gang with room thermostat Figure 9 Press the sensor button ¨ to select menu item CL60 for the cleaning function and then press the sensor button OK(Figure 9). All the functions on the device are blocked for 60 s. All the status LEDs of the sensor buttons flash.
  • Page 8 Touch/Glass sensor 2gang / 3gang with room thermostat 5.1 Touch sensor with room thermostat Mounting and connecting the Touch sensor Figure 10 (5) Power supply connection (6) Connection of wired floor temperature/remote sensors (accessories) (7) KNX connection (8) Programming LED (9) Programming button The device is installed by screwing the mounting frame to the appliance box or to the wall.
  • Page 9 Touch/Glass sensor 2gang / 3gang with room thermostat Figure 11 (10) Mounting frame (11) Retaining screw 5.2 Glass sensor with room thermostat Preparing the Glass sensor for mounting on a smooth substrate Figure 12 (12) Adhesion points for adhesive dots (13) Retaining peg The adhesive dots prevent the glass sensor from slipping when mounted on smooth surfaces.
  • Page 10 Touch/Glass sensor 2gang / 3gang with room thermostat Mounting and connecting the Glass sensor Use the double installation socket (accessory). Mounting on single concealed sockets is not possible. Optional: For increased dismantling protection or to increase the shadow gap to the wall, use the enclosed mounting frame (10).
  • Page 11 Touch/Glass sensor 2gang / 3gang with room thermostat Lever the friction spring seats (16) out of the appliance box, in order to reveal the screw holes of the installation socket. Align the mounting frame and screw it to the appliance box of the wall. Observe marking TOP = TOP.
  • Page 12: Troubleshooting

    Touch/Glass sensor 2gang / 3gang with room thermostat Load application software into the device. 6 Appendix 6.1 Technical data KNX medium TP 1 Commissioning mode S-mode Rated voltage KNX DC 21 ... 32 V SELV Power consumption KNX typical 150 mW Connection mode KNX Connection terminal Ambient temperature...
  • Page 13: Warranty

    Our products are under guarantee within the scope of the statutory provisions. If you have a warranty claim, please contact the point of sale or ship the device postage free with a description of the fault to the appropriate regional representative. Berker GmbH & Co. KG Klagebach 38 58579 Schalksmühle/Germany...

This manual is also suitable for:

Knx touch glass sensor 3gang