Premier air/hydraulic presses 20 & 30 tonne floor type with sliding ram and foot pedal

Advertisement

4. ASSEMBLY
4.1.
Fitting Feet.
Raise the press to remove the transit supports and replace with the permanent feet (fig.2).
WARNING: Be aware that this unit is top-heavy.
fig.2
4.2.
Air Motor
Connect the air motor to the base plate as in figs.6 and 7.
4.3.
Fitting Pedals
4.3.1. Fit the pump pedal levers to the pivots using the fixings provided (fig.3).
4.3.2. Once the pedal levers are restraining the pump pistons, remove the pins from behind (fig.4).
4.3.3. Place the end caps over the feet and lower the pedal housing over the pedals and end caps (fig.5).
4.3.4. Screw the pedal covers over the end caps to secure.
4.3.5. Fix the pedals to the pedal levers (fig.8)
fig.5
4.4.
Air Supply
4.4.1. Connect the 1/4"BSP air inlet connector situated at the rear of the press (fig.9)
to the compressed air supply using hose with a minimum diameter of
1/2" (fig.10).
4.4.2. An air supply pressure of between 7 and 10bar (100 -145psi) is
recommended.
© Jack Sealey Limited
fig.1
fig.3
fig.6
Original Language Version
fig.4
fig.7
fig.8
fig.10
PPF301, PPF501 Issue:3(I) 21/07/17
fig.6
fig.9