User's Manual
PMM PA6001
WIDEBAND RF POWER
100 kHz - 250 MHz / 40 Watts
SERIAL NUMBER OF THE INSTRUMENT
You can find the Series Number on the rear panel of the instrument.
Series Number is in the form: 0000X00000.
The first four digits and the letter are the Series Number prefix, the last five digits are
the Series Number suffix. The prefix is the same for identical instruments, it changes
only when a configuration change is made to the instrument.
The suffix is different for each instrument.
Document PA6001EN-70601 – Copyright © NARDA 2017
www.atecorp.com
(800) 404-ATEC
Manufacturing Plant:
Via Benessea, 29/B
17035 Cisano sul Neva (SV)
ITALY
Tel.: +39 0182 58641
Fax: +39 0182 586400
AMPLIFIER

Advertisement

loading
Need help?

Need help?

Do you have a question about the PMM PA6001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Atec PMM PA6001

  • Page 1 Fax: +39 0182 586400 Fax: +39 02 26998700 S.r.l. Socio Unico http://www.narda-sts.it User’s Manual PMM PA6001 WIDEBAND RF POWER AMPLIFIER 100 kHz - 250 MHz / 40 Watts SERIAL NUMBER OF THE INSTRUMENT You can find the Series Number on the rear panel of the instrument.
  • Page 2 NOTE: Do not use the equipment in a function not specified by the manufacturer. This instruction manual must be read before attempting to install or operate the amplifier. Before using the equipment the user must insure that all instructions at switch on as indicated in chapter 2 have been properly made and checked.
  • Page 3 Contents Page General safety considerations and instructions..EC Declaration of Conformity …………………………... 1 General information Page 1.1 General information…......…....1.2 Main specifications......…......2 Installation Page 2.1 Mains supply cable.......…....2.2 Auxiliary earth conductor connection..…....2.3 Air intake and escape (in house installation)..... 2.4 Weight of the equipment.......…....
  • Page 4 Figures Figure Page PA6001 ………….……………………………… PA6001 Auxiliary earth conductor connection PA6001 front panel…………………………….. Tables Table Page Main Specifications PA6001………………….. Contents...
  • Page 5 SAFETY RECOMMENDATIONS AND INSTRUCTIONS To maintain it in safe conditions and ensure correct use, these general instructions must be fully understood and applied before the product is used. • CAT 1 Terminals are present on the equipment; do not use for categories of measurement II, III and •...
  • Page 6 Dichiarazione di Conformità EU Declaration of Conformity In accordo alla Decisione 768/2008/EC, conforme alle direttive EMC 2014/30/UE, Bassa Tensione 2014/35/UE e RoHS 2011/65/UE, ed anche alle norme ISO/IEC 17050-1 e 17050-2. In accordance with the Decision 768/2008/EC, compliant to the Directives EMC 2014/30/EU, Low Voltage 2014/35/EU and RoHS 2011/65/EU, also compliant to the ISO/IEC standard 17050-1 and 17050-2 Il costruttore narda...
  • Page 7 1 - General Information 1.1 General Information The PA6001 amplifier is an up-to-date and high-performance equipment leading to all kinds of applications: - EMC tests of radiated susceptibility (antennas, striplines, TEM and GTEM cells, etc), - EMC tests of conducted susceptibility, according to each type of couplings - Direct coupling, - Capacitor coupling ,...
  • Page 8 1.2 Main specifications TABLE 1-1 Technical specifications 100 kHz – 250 MHz Frequency bandwidth 40 W Typical output power Power at 3 dB compression 40 W min. up to 100 MHz / 35 W min. from 100 MHz to 250 MHz Power at 1 dB compression 35 W min.
  • Page 9 2 - Installation The mains cable is connected to a single phase network (16A min + 2.1 Mains supply cable neutral + ground). The typical current measured when the amplifier is in RF ON mode (amplification is active) is : 110 Vac : = 3.7 Amps AC 230 Vac : = 1.8 Amps AC Use a plug with minimum rating of 16 A min.
  • Page 10 2.5 Moving of the In the event of displacement, first of all switch off the amplifier, disconnect equipment the equipment of the electrical supply network, then all the external cables (including the connections of ground) must be removed 2.6 RF interconnections The cables used must be of a sufficient quality to allow operation up to 1000 MHz and to withstand the power delivered by the amplifier.
  • Page 11 3 – Operating Instruction 3.1 Front panel in The mains cable is connected to a single phase network (16A min + standard neutral + ground). The typical current measured when the amplifier is in RF configuration ON mode (amplification is active) is : 110V AC : = 3.7 Amps AC 230V AC : = 1.8 Amps AC Fig.
  • Page 12 "POWER" Push the mains switch after following the instructions presented in § 2.7. Switch on For the operator safety, do not connect or disconnect the load when the amplifier delivers the RF signal. When the amplifier is on the “RF ON” mode and during any change of input signal conditions, special care must be taken against transient and spurious signals generation.
  • Page 13 4 – Maintenance 4.1 1 Level When no output power can be measured on the output of the amplifier : Maintenance Check the level of RF input signal of the generator. If this point indicates there is no defect, call Narda customer care service. 4.2 Preventive A simple check of the output power over the frequency bandwidth allows to maintenance...
  • Page 14 This page intentionally left blank Maintenance...
  • Page 15 Sales & Support: Manufacturing Plant: NARDA Via Leonardo da Vinci, 21/23 Via Benessea, 29/B Safety 20090 Segrate (MI) - 17035 Cisano sul Neva (SV) ITALY Test Tel.: +39 0182 58641 Tel.: +39 02 2699871 Solutions Fax: +39 0182 586400 Fax: +39 02 26998700 S.r.l.
  • Page 16 Suggerimenti / Commenti / Note: Suggestions / Comments / Note:...