Advertisement

Quick Links

AURORA LED STRIP
4 CELL
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Strand AURORA LED STRIP 4 CELL and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGNIFY Strand AURORA LED STRIP 4 CELL

  • Page 1 AURORA LED STRIP 4 CELL USER MANUAL...
  • Page 2: Included Items

    COMPONENTS The document provides installation and operation instructions for the following products: • Strand Aurora LED Strip 4 Cell Read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet.
  • Page 3: Installation

    AURORA LED STRIP 4 CELL USER MANUAL INSTALLATION MOUNTING The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight.
  • Page 4 AURORA LED STRIP 4 CELL USER MANUAL TABLE 1. MENU FUNCTIONS LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 DEFAULT Address 001~512 (Default 001) LED Hours XXXXXX h Reset LED Hour Are you sure? Square Curve (Default) Dimming Curve S Curve...
  • Page 5 AURORA LED STRIP 4 CELL USER MANUAL TABLE 1. MENU FUNCTIONS LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 DEFAULT Address 001~512 SSCC (Default) DMX Mode SQCC SOCC Group 1 (Default) Pixel Group Group 3 Group 12 Normal (Default) Cell Direction...
  • Page 6: Address Menu

    AURORA LED STRIP 4 CELL USER MANUAL ADDRESS MENU Address — DMX address setting. To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
  • Page 7: Fixture Menu

    AURORA LED STRIP 4 CELL USER MANUAL unit idle one minute to exit menu mode. Data — To select Data, press the ENTER button to confirm. Use the UP/DOWN button to select Ch1 – Intensity xxx(value), Ch2 – Intensity Fine xxx(Value), …. All functions, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
  • Page 8: Dmx Mapping

    AURORA LED STRIP 4 CELL USER MANUAL DMX MAPPING The fixture can be operated by DMX controller. The following tables assumes a DMX start address of 1. When a diff erent starting address is used, this address becomes channel 1 function and other functions follow in se- quence.
  • Page 9 AURORA LED STRIP 4 CELL USER MANUAL TABLE 2. SSCC MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL 115 - 118 Yellow 119 - 122 Deep Amber 123 - 126 Chrome Orange 127 - 130 Orange 131 - 134 Magenta 135 - 138 Flame Red 139 - 142 Purple...
  • Page 10 AURORA LED STRIP 4 CELL USER MANUAL TABLE 2. SSCC MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL 76 - 80 Reserved Values 81 - 85 Reserved Values 86 - 90 Reserved Values 91 - 95 Color Calibration on 96 - 100 Color Calibration off (Default) 101 - 105 Reserved Values...
  • Page 11 AURORA LED STRIP 4 CELL USER MANUAL TABLE 3. SSCC MODE: 4 CELL SELECTED - ADDITIONAL CHANNELS ADDED PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL Cyan (High) Cyan Color Level Control 0 - 100% Saturation 0 - 65535 6 Color LED array auto adjust to meet Cyan / mixed color point Cyan (Low) of full available color spectrum Yellow (High)
  • Page 12 AURORA LED STRIP 4 CELL USER MANUAL TABLE 3. SSCC MODE: 4 CELL SELECTED - ADDITIONAL CHANNELS ADDED PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL Variable color temperature control channel Channel works Independent of color mixing channel and will adjust all mixed c 0 - 250 color from selected color temperature level.
  • Page 13 AURORA LED STRIP 4 CELL USER MANUAL TABLE 3. SSCC MODE: 4 CELL SELECTED - ADDITIONAL CHANNELS ADDED PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL CELL 4 Cyan (High) Cyan Color Level Control 0 - 100% Saturation 0 - 65535 6 Color LED array auto adjust to meet Cyan / mixed color point Cyan (Low) of full available color spectrum Yellow (High)
  • Page 14 AURORA LED STRIP 4 CELL USER MANUAL TABLE 4. SQCC MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL Intensity (High) 16bit Intensity (Dimmer) Control 0 - 65535 0 - 100% Output Intensity (Low) 0 - 255 Strobe S>>>>>F 0 - 9 No Strobe Function - Shutter open 10 - 99 Strobe S>>>>>F...
  • Page 15 AURORA LED STRIP 4 CELL USER MANUAL TABLE 4. SQCC MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL 151 - 154 User Preset 3 155 - 158 User Preset 4 159 - 162 User Preset 5 163 - 166 User Preset 6 167 - 170 User Preset 7 171 - 174...
  • Page 16 AURORA LED STRIP 4 CELL USER MANUAL TABLE 5. SOCC MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL 59 - 62 Slate Blue 63 - 66 Regal Blue 67 - 70 Full C.T Blue 71 - 74 Steel Blue 75 - 78 Lighter Blue 79 - 82 Cyan...
  • Page 17 AURORA LED STRIP 4 CELL USER MANUAL TABLE 5. SOCC MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL Control Channel used for full fi xture settings lamp controls 0 - 255 Set discrete value of desired effect then set value to 0 (Idle). ”**Function does not require 3 Second rule to active to value will automatically activate function 0 - 5...
  • Page 18 AURORA LED STRIP 4 CELL USER MANUAL TABLE 5. SOCC MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL Amber (High) 0 - 65535 Amber Color Level Control; 0 - 100% Saturation Amber (Low) Lime (High) 0 - 65535 Lime Color Level Control; 0 - 100% Saturation Lime (Low) Cyan (High) 0 - 65535...
  • Page 19 AURORA LED STRIP 4 CELL USER MANUAL TABLE 6. SOCC MODE: 4 CELL SELECTED - ADDITIONAL CHANNELS ADDED PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL Red (High) 0 - 65535 Red Color Level Control; 0 - 100% Saturation Red (Low Green (High) 0 - 65535 Green Color Level Control;...
  • Page 20 AURORA LED STRIP 4 CELL USER MANUAL TABLE 7. COLOR PRESETS RANGE DMX COLOR RANGE DMX COLOR 195 - 198 User Preset 14 215 - 218 User Preset 19 199 - 202 User Preset 15 219 - 222 User Preset 20 203 - 206 User Preset 16 223 - 255...
  • Page 21 AURORA LED STRIP 4 CELL USER MANUAL TABLE 9. CONTROL CHANNEL FUNCTION RANGE POWER CYCLE ITEMS DESCRIPTION SELECTION RULES CHANNEL VIA UI If fi xture is powered down Shuts down all fi xture output and turns off all then up fi xture 11 - 15 Fixture Shutdown fans - fi...
  • Page 22 AURORA LED STRIP 4 CELL USER MANUAL TABLE 9. CONTROL CHANNEL FUNCTION RANGE POWER CYCLE ITEMS DESCRIPTION SELECTION RULES CHANNEL VIA UI Takes Current Color mixing values and stores to next available blank Record User Color 151 - 155 User color preset - if preset listing are full Preset** preset will not record.
  • Page 23: Dmx 512 Connection

    AURORA LED STRIP 4 CELL USER MANUAL DMX512 CONNECTION • At last unit, the DMX cable has to be terminated with a terminator. Solder a 120Ω 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 5-pin XLR-plug and plug it in the DMX-output of the last unit. •...
  • Page 24: Care And Maintenance

    AURORA LED STRIP 4 CELL USER MANUAL APPENDIX A CARE AND MAINTENANCE TROUBLESHOOTING Following are a few common problems that may occur during operation. The unit does not work - light and fan do not turn on • Check the connection of power and main fuse. •...
  • Page 25 AURORA LED STRIP 4 CELL USER MANUAL ADDENDUM Fan Speed and Control All Vari-lite and Strand lighting luminaires will be governed by the same Fan speed v Noise levels v Maximum power output rules as details below. These noises related to these levels will confi rm to Noise Criteria levels details of which are contained within the document.
  • Page 26: How To Obtain Warranty Service

    To obtain warranty service, please contact customer service at 1-214-647-7880, or entertainment.service@ signify.com and request a Return Material Authorization (RMA) for warranty service. You will need to provide the model and serial number of the item being returned, a description of the problem or failure and the name of the registered user or organization.
  • Page 27 All trademarks are owned by Signify Holding or their respective owners. The information pro- vided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon.