1000W Power Converter 260-9520 To Reduce The Risk Of Injury, User Must Read And Understand Operator’s Manual. Save These Instructions For Future Reference. 0099002187-00...
TABLE OF CONTENTS Safety Symbols ................Page 3 Safety Information ................Page 4 Important Safety Instructions ............Page 5 Personal Precautions ..............Page 6 Converter Location .................Page 6 Features ..................Page 6 Specifications .................Page 7 Replacement Parts .................Page 7 Before Using Your Converter ............Page 7 Fastening the Converter to a Flat Surface ........Page 8 Connecting Converter Cables ............Page 8 Battery Bank Instructions ..............Page 9...
SAFETY SYMBOLS Some of the following symbols may be used on your converter Please study them and learn their meaning. Proper interpretation of these symbols will allow better and safer operation of the converter. Symbol Name Designation/Explanation Volts Voltage Amperes Current Hertz Frequency...
SAFETY INFORMATION The purpose of safety symbols is to attract our attention to possible dangers. The safety symbols, and the explanations with them, deserve your careful attention and understanding. The symbol warnings do not by themselves eliminate any danger. The instructions and warnings they give are no substitutes for proper accident pre- vention measures.
260-9520. This manual will come into contact with any power show you how to use your converter source are wet. Water and many other safely and effectively.
2. PERSONAL PRECAUTIONS 2.1 Restrictions on Use: This converter 2.3 Remove all personal metal items from may not be used with life support your body, such as rings, bracelets, devices or systems. Failure of this con- necklaces and watches. A lead-acid verter can reasonably be expected to battery can produce a short circuit cause failure of that life support device...
5. SPECIFICATIONS Nominal input voltage ..............12.8-13.2 VDC Nominal output voltage ..............110-125 VAC Output frequency ................60 Hz ± 3 Hz Operating input voltage ..............10.5-15.5 VDC Continuous output power ..............Up to 1000 W Surge output power (0.1 second) .............. 2000 W Waveform ................Modified sine wave Maximum efficiency ..................
IMPORTANT: Always run a test to establish Using the converter with any of these whether the converter will operate a par- devices may cause the device to run ticular piece of equipment or device. In the warmer or overheat. event of a power overload, the converter is designed to automatically shut down.
TO GROUND THE CONVERTER (BLACK) terminal screw. Tighten each terminal so that the cable cannot come 1. Turn off and disconnect the converter. loose. 2. Locate the chassis ground screw on the CONNECTING THE CONVERTER back of the converter. CABLE TO A 12V BATTERY 3.
7. Make sure the converter’s switch is set to OFF (O). RISK OF EXPLOSIVE GASES. 8. Connect the output cables from the battery bank to the converter. • Assemble the battery bank in a clean, well-ventilated location, away from igni- tion sources and flammable materials.
IMPORTANT: Using the converter with rite Data Line Filters can be purchased some rechargeable devices may damage at most electronic supply stores. the converter and/or device. If you are 4. Try grounding the converter with a 16 using the converter to operate a recharge- AWG (minimum) wire, using as short able device, monitor the temperature of of an extension length as possible.
13. LED INDICATOR AND SHUTDOWN PROTECTION The Green LED lights automatically when equipment or device being operated then converter is plugged into a 12 volt DC exceeds the continuous load rating of power source and is turned on. The Red the converter.
16. TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Low or no output voltage. Poor contact at terminals. Disconnect and reconnect the 12V connections. Using incorrect type of Use a true RMS reading voltmeter to test output meter. voltage. Red LED is lit. The battery voltage is Recharge or replace the below 10 volts.
This MASTERFORCE™ brand power converter carries our famous No Hassle 3-Year Limited Warranty to the original purchaser. If, during normal use, this MASTERFORCE™ product breaks or fails due to a defect in material or work- manship within three (3) years from the date of original purchase, simply bring...