Rheem Raypak RPAGP75 Installation And Operation Manual page 7

Table of Contents

Advertisement

Before installing the pump, make sure that the
surface is solid, elevated, rigid and vibration free.
Secure the pump to the base with screws or bolts
to limit the vibration and the stress on the pipes and
joints.
Leave enough space for the isolation and check
valves on the suction and discharge piping, as
required.
Connect the suction and discharge pipes to the outlet
and inlet of the swimming pool.
Make sure that ground level drainage is adequate so
as to prevent flooding.
CONTROLLED COPY approved for factory use on 4/16/2020. RAYPAK PROPRIETARY AND CONFIDENTIAL INFORMATION . Approva
6.3" (160 mm)
10.8"
(274 mm)
Model
Input power
RPAGP75
0.55kW
RPAGP100
0.75kW
RPAGP102
0.75kW(Max)
RPAGP150
1.1kW
RPAGP152
1.1kW(Max)
DO NOT store or use gasoline or other flammable
vapors or liquids in the vicinity of this pump. DO NOT
store pool chemicals near the pump.
DO NOT remove any safety alert labels such as
DANGER, WARNING, or CAUTION. Keep safety
labels in good condition and replace any missing or
damaged labels.
Make sure that the pump and piping are accessible
for servicing.
NOTE: The pump suction and discharge connections
have molded-in thread stops. DO NOT try to screw pipes
beyond these stops.
24.4" (620 mm)
Figure 2.
Dimensions
Power (HP)
Speed
0.75
Single
1.0
Single
1.0
Dual
1.5
Single
1.5
Dual
Table A.
Specifications
Connection
Voltage
Size
115V/60Hz
1.5"
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents