Control 1.3 Swimming Pool Control Unit Table of Contents Table of Contents Table of Contents ........................ 1 General Note ........................3 Information on the Operating Manual ..............3 Explanation of Symbols ..................3 Limitation of Liability ....................4 Copyright ....................... 4 Warranty Conditions ....................
Page 4
Control 1.3 Swimming Pool Control Unit Table of Contents Operation ........................21 Safety Instructions for Operating the Control Unit ..........21 Commissioning.....................21 Menu Structure.....................21 General Menu Navigation ..................22 Maintenance .........................40 Safety Instructions for Transport ................40 Maintenance / Repairs ..................40 Faults ..........................41 Safety Instructions for Troubleshooting ..............41 Behaviour in the Case of Faults ................41...
The operating manual is part of the product and must be kept accessible to the user at all times in close proximity to the swimming pool control unit. This operating manual provides important information on how to use the “BEHNCKE Control 1.3” swimming pool control unit. Compliance with all specified safety information and instructions is essential to ensure safe working.
Control 1.3 Swimming Pool Control Unit General Note NOTE! ...indicates a potentially dangerous situation that can lead to property and environmental damage if not avoided. 1.2.2 Tips and Recommendations ...draws attention to useful tips and recommendations and information to maintain efficient and trouble-free operation.
If you have any questions about the product, please contact: Phone: +49 (0)89 456917 – 0 Email: info@behncke.com General Information about the Product The product designated the “BEHNCKE Control 1.3” swimming pool control unit consists of the components listed in Table 1: Number Article number Article description BEHNCKE Control 1.3...
Control 1.3 Swimming Pool Control Unit Safety Safety This section gives an overview of all the important safety aspects for the optimum protection of people and to guarantee safe and trouble-free operation. Failure to observe the instructions and safety information in this manual may result in serious danger.
Control 1.3 Swimming Pool Control Unit Safety Dangers in Handling the Control Unit The swimming pool control unit has been built in accordance with the latest technological standards and the recognised safety regulations. Nevertheless, the following dangers may occur when the unit is used - in particular in the case of incorrect operation or misuse: ...
Unexpected Start-up DANGER! Risk of fatal injury from an unexpected start-up The BEHNCKE Control 1.3 works as soon as there is voltage at the power input and the individual functions are called up immediately. Secure the control unit against unauthorised access.
Control 1.3 Swimming Pool Control Unit Safety Sources of Danger and Residual Risks The operating instructions for the individual built-in components and peripherals must be consulted for all sources of danger and residual risks. Danger! The electrical equipment on the system is under high voltage. You should therefore observe the following information: ...
Compliance with the Degree of Protection After carrying out work on the BEHNCKE Control 1.3, moisture may penetrate into the device if the housing or individual cable glands are not closed properly, ensuring that there is a reliable seal. This can lead to damage or destruction of the control unit or result in malfunctions.
Control 1.3 Swimming Pool Control Unit Safety Personnel Requirements 2.9.1 Qualifications WARNING! Risk of injury in the case of inadequate qualifications! Improper handling can lead to serious personal injury and property damage. Specific activities must only be carried out by the people designated in the respected chapter of this manual.
Control 1.3 Swimming Pool Control Unit Safety Have read and understood this operating manual – in particular the safety chapter and warnings. Responsibility of the Operator The control unit is used in the private sphere. The operator must: ...
Page 15
Control 1.3 Swimming Pool Control Unit Safety Alert a doctor and/or the fire service. Inform the responsible people at the place of use. Clear access routes for emergency vehicles.
Control 1.3 Swimming Pool Control Unit Technical Data Technical Data Terminal Assignment Check which system components are available before starting the installation. Then observe the circuit diagrams for connecting the unit that are included in this manual. Pay attention to the information included in the circuit diagrams in this manual.
Control 1.3 Swimming Pool Control Unit Technical Data 3.1.2 Outputs Type Name Description Outputs 3*230 V / 10 Filter pump Control 1.3 Collector pump Triac Heating pump 230 V / 3 A Relays UV lamp 230 V / 3 A...
Page 18
Control 1.3 Swimming Pool Control Unit Technical Data...
Control 1.3 Swimming Pool Control Unit Technical Data Operating Conditions The control unit must only be operated under the following conditions: If all the wiring has been carried out by a specialist in accordance with the applicable standards The area must be frost-proof.
Control 1.3 Swimming Pool Control Unit Transport, Packaging and Storage Transport, Packaging and Storage Safety Instructions for Transport Unauthorised transport NOTE! Damage caused by improper transport Substantial property damage may occur in the case of improper transport. Proceed carefully when unloading packages, with deliveries and with internal transport and observe the symbols on the packaging.
Control 1.3 Swimming Pool Control Unit Installation and Commissioning Installation and Commissioning Safety Instructions for Installation and Initial Commissioning The installation and initial commissioning should only be carried out by a systems mechanic or specialist! Work on the electrical equipment must only be carried out by qualified electricians.
Control 1.3 Swimming Pool Control Unit Installation and Commissioning Electrical Connection The electrical connection must only be carried out by a qualified electrician. The local regulations and the VDE 0100 regulation must be taken into account. A main (emergency stop) switch must be installed on-site in the control unit power supply.
Control 1.3 Swimming Pool Control Unit Operation Operation Safety Instructions for Operating the Control Unit WARNING! Risk of injury due to improper operation! Improper operation can lead to serious injuries or property damage. Operate the control unit in accordance with the information in this operating manual.
Control 1.3 Swimming Pool Control Unit Operation System status System information Balance values Backwash protocol Messages Date/time Language Activate/deactivate portal Switching times Trigger backwashing Switching times Backwashing setting Filter cleaning Rinsing setting Pause Forced overflow channel Pump type Frequency converter settings...
Page 25
Control 1.3 Swimming Pool Control Unit Operation The user scrolls to the next page within the menu by tapping on the arrow keys on the right-hand side of the screen The user accesses the corresponding submenu by tapping on a blue button ...
Page 26
Control 1.3 Swimming Pool Control Unit Operation The control function is switched on and off by tapping on the left ON/OFF button. The button turns green when the control unit is switched on. The button turns blue when the control unit is switched off.
Page 27
Control 1.3 Swimming Pool Control Unit Operation Service level: If a red line is displayed at the top of the screen, the user is in the service level and has access to all menu items. 6.4.2 General Settings Menu 6.4.2.1...
Page 28
Control 1.3 Swimming Pool Control Unit Operation The reason for which the message appeared 6.4.2.6 Setting the Time & Date The user can set the current date and time in the control unit in the “Date/Time” submenu. The values are stored in the control unit so that these values do not need to be reset after a power failure.
Page 29
Control 1.3 Swimming Pool Control Unit Operation Backwashing settings (running time and backwash valve type) Rinsing settings (running time and rinse valve type) Pause for which the pump turns off so that the valves can move Forced filtration running time through the pool overflow channel after backwashing (select only when...
Page 30
Control 1.3 Swimming Pool Control Unit Operation Figure 4: Backwashing setting In field you choose the backwash valve type. You can choose between a rod valve and a Badutronic valve. In field you set the running time of the backwashing.
Page 31
Control 1.3 Swimming Pool Control Unit Operation The Forced Overflow Channel submenu is only available if an overflow pool has been set as the pool type Level Control Pool Type). The filter pump continues to run at normal speed for (Treatment the set time (max.
Page 32
Control 1.3 Swimming Pool Control Unit Operation Figure 5: Frequency converter settings Table 2: Frequency converter circuit diagram (X marks the active switching status) Frequency Speed Terminal A13 Terminal A14 Terminal A15 Terminal A16 converter type Reduced Normal Increased Stop...
Page 33
You need to go to the Treatment Level Control submenu to set the level control. This is shown in Figure 7. Pool type: defines whether the pool is a skimmer or overflow pool. A Behncke level control (art no. 39019095) is required as an add-on module for overflow pools.
Page 34
Control 1.3 Swimming Pool Control Unit Operation Max. fill time: defines the maximum time for which the fill valve can be continuously controlled. If the time is exceeded, the fill valve is switched off and an error message is displayed.
Page 35
Control 1.3 Swimming Pool Control Unit Operation 6.4.3.7 ECO Functions You need to go to the Treatment ECO Function submenu to set the ECO functions. This is shown in Figure 8. Floor valve: defines whether a floor valve is connected The floor valve is automatically activated when the roller shutter is closed and water is therefore drawn in through the floor drain.
Page 36
Control 1.3 Swimming Pool Control Unit Operation 6.4.3.9 Forced On You need to go to the Treatment Forced On submenu to set the forced activation. The input for the forced activation of the filter pump is defined here. The filter pump runs at normal speed as long as there is a signal on the input.
Page 37
Control 1.3 Swimming Pool Control Unit Operation Figure 9: Auxiliary heating The water sensor (PT1000) must be connected to the terminals E4. The heating pump/heating solenoid valve must be connected to the terminals A3 (230 V). The release signal for the heating must be connected to the terminals A12.
Page 38
Control 1.3 Swimming Pool Control Unit Operation Difference: defines the minimum required temperature difference between the solar and swimming pool water temperature to activate the solar mode. Forced: defines whether the filter pump must be switched on for solar operation outside of the switching times.
Page 39
Control 1.3 Swimming Pool Control Unit Operation value is too high. A positive correction value must be entered if the measured value is too low. The difference between the measured value and the target temperature of the swimming pool water must be entered as a correction value.
Page 40
Control 1.3 Swimming Pool Control Unit Operation Input: defines on which input terminals the values should be read Signal type: defines whether the values are transmitted as a 0-10 V or 4-20 mA signal Value for X: defines the transmission value range Figure 11: Measurement and control technology Fixed limit values for the read values are stored in the control unit.
Page 41
Control 1.3 Swimming Pool Control Unit Operation Figure 12: Chemical fill level 6.4.5.5 Factory Settings You need to go to the Extras Factory Settings submenu to reset the control unit to the factory settings. The control unit is reset if you confirm the query with “Yes”.
Control 1.3 Swimming Pool Control Unit Maintenance Maintenance Safety Instructions for Transport Basic Information WARNING! Risk of injury due to improperly carried out maintenance work! Improper maintenance can lead to serious injuries or property damage. Before starting, ensure that there is sufficient room to carry out the installation work.
Control 1.3 Swimming Pool Control Unit Faults Faults Safety Instructions for Troubleshooting Basic Information WARNING! Risk of injury due to improper troubleshooting! Improper troubleshooting can lead to serious injuries or property damage. Before starting, ensure that there is sufficient room to carry out the installation work.
Page 44
Control 1.3 Swimming Pool Control Unit Faults the supply lines Temperature sensor error The measured temperature values are outside of the logic limits stored in the control unit. Please check the line and the temperature sensor for damage. Lack of water in the overflow tank...
Page 45
Control 1.3 Swimming Pool Control Unit Faults Please set the date in the “General” menu. Please set date Calibration process failed (I > 8 A) The motor current is greater than 8 A. The power must not be supplied via the control unit.
Control 1.3 Swimming Pool Control Unit Spare Parts Spare Parts WARNING! Risk of injury due to incorrect spare parts! Incorrect or faulty spare parts can lead to damage, malfunctions or a total failure and compromise safety. Use only original spare parts supplied by the manufacturer...
Control 1.3 Swimming Pool Control Unit Disassembly and Disposal Disassembly and Disposal When it reaches the end of its service life, the control unit must be disassembled and disposed of in an environmentally friendly manner. Disassembly Before the disassembly work starts: ...
Germany erklären in alleiniger Verantwortung, daß das Produkt declare under our sole responsibility, that the product declarons sous notre seule responsibilité, que le produit Bezeichnung Behncke Control 1.3 Name Typ,Modell,Artikel-Nr., Größe IBB Artikelnr. 7739 Type,Model, Article No.,Taille Type, Modèle, Mo.d'Article,Taille...
Page 49
DIN EN 61000-3-3; VDE 0838-3:2014-03 - Elektromagnetische Verträglichkeit (EMV) - Teil 3- 3:Grenzwerte - Begrenzung von Spannungsänderungen,Spannungsschwankungen und Flicker in öffentlichen Niederspannungs-Versorgungsnetzen für Geräte mit einem Bemessungsstrom <= 16 A je Leiter, die keiner Sonderanschlussbedingung unterliegen (IEC 61000-3-3:2013); EN 61000-3- 3:2013 DIN EN 61000-4-2;...
Control 1.3 Swimming Pool Control Unit Connection Diagrams Connection Diagrams You will find connection and terminal diagrams to assist you on the following pages. You will also find the belonging app if you scan the QR-Codes below. Link Android-App Link iOS-App...
Page 60
Control 1.3 Swimming Pool Control Unit BEHNCKE GmbH Bavaria: Michael-Haslbeck Straße 13 85640 Putzbrunn, Germany Phone: +49 (0)89 / 45 69 17-0 Fax: +49 (0)89 / 46 85-11 Saxony-Anhalt: Stötterlinger Straße 36 a 38835 Bühne, Germany Phone: +49 (0)39421 / 796-0...
Need help?