User Manual for Spot-Check Monitor This Manual is written for the current Spot-Check Monitor. The Manual describes, in accordance with the Spot-Check Monitor’s features and requirements, main structure, functions, specifications, correct methods for transportation, installation, usage, operation, repair, maintenance and storage, etc. as well as the safety procedures to protect both the user and equipment.
Page 3
Thank you for purchasing this quality product. Please read the following information very carefully before using this device. Read these instructions carefully before using this Spot-Check Monitor. These instructions describe the operating procedures to be followed strictly. Failure to follow these instructions can cause monitoring abnormity, equipment damage and personal injury.
Page 4
User Manual for Spot-Check Monitor Cautions: This device is used for measurement. Do not use for self-diagnose and it is not a treatment device. This device is applicable to adult. This device is not designed to be used in movable vehicle (such as a car, airplane).
Page 5
User Manual for Spot-Check Monitor and electric system requirements. Do not modify or disassemble this device and the cuff without authorization of the manufacturer. Although biocompatibility tests have been performed on all the applied parts, some exceptional allergic patients may still have anaphylaxis. Do NOT apply to those who have anaphylaxis.
Page 6
User Manual for Spot-Check Monitor Note: ☞ In this Manual, "long press" means press and hold key for about 3 seconds; "short press" means press key for less than 1 second.
User Manual for Spot-Check Monitor Table of contents CHAPTER 1 OVERVIEW....................1 1.1 Features........................ 1 1.2 Application and Scope..................1 1.3 Conformation......................1 1.4 Product Name and Model..................2 1.5 Working Environment and Power Supply............2 CHAPTER 2 APPEARENCE....................4 CHAPTER 3 INSTALLATION AND CONNECTION............... 7 CHAPTER 4 MEASUREMENT .....................8...
Page 8
User Manual for Spot-Check Monitor 5.3 Pulse Rate Measurement (Optional)..............15 5.4 Wireless Communication................... 15 5.5 Classification.......................16 5.6 Dimension and Weight..................16 CHAPTER 6 MAINTENANCE AND SERVICE..............17 6.1 Technical Maintenance..................17 6.1.1 Daily Examination..................17 6.1.2 Battery Maintenance................18 6.2 Cleaning and Disinfection of the Main Unit............18 ..........
Android and IOS system. 1.2 Application and Scope The Spot-Check Monitor is applicable for measuring adult's physiological parameters, such as non-invasive blood pressure (NIBP), functional oxygen saturation (SpO ), and pulse rate (PR).
User Manual for Spot-Check Monitor software package running on the host system. 1.4 Product Name and Model Name: Spot-Check Monitor Model and Configuration: ("√" means function is available, and "--" means function is not available). Configuration Remarks Model NIBP Pulse Rate PC-101 √...
Page 11
User Manual for Spot-Check Monitor Internal power supply by built-in battery: d.c. 3.7V (lithium battery) with capacity 1000mAh. When the device is charging, the icon " " will be displayed on the screen (in scroll status), when the device is full charged, the icon turns to be "...
User Manual for Spot-Check Monitor CHAPTER 2 APPEARENCE 1. Display screen 2. Power switch 5. Cuff and wrapper 3. General connector 4. Charging port Figure 2.1 Demonstration...
Page 13
User Manual for Spot-Check Monitor 1. " ": display screen. 2. " ": power switch. Long pressing to turn on/off the device; Short pressing to start/cancel NIBP measurement. 3. " ": general connector. It can be used to connect SpO probe.
Page 14
User Manual for Spot-Check Monitor Symbol Description Symbol Description Type BF applied parts Serial number "Attention!"--please refer to the Class II device User Manual Battery is fully charged Battery is charging (rolling bar) Following WEEE regulations for Manufacturing date disposal...
User Manual for Spot-Check Monitor CHAPTER 3 INSTALLATION AND CONNECTION The measurement result of Spot-Check Monitor can be ALSO displayed, stored and managed via the APP software installed in a host device (such as smart phone , tablet, computer etc.), so before making measurement, please install APP software firstly and make sure the APP software connects to the Spot-Check Monitor via wireless successfully.
User Manual for Spot-Check Monitor CHAPTER 4 MEASUREMENT 4.1 Blood Pressure Measurement Long pressing power switch " ", the device displays software version number and UID, and 1.5 seconds later, it enters into the default screen, as shown in figure 4.1.
Page 17
User Manual for Spot-Check Monitor Take off the sweater or the thick cloth to make the arm is uncovered or only one thin cloth left. Before making measurement, do not eat, drink, smoke, take exercise or have a bath.
Page 18
User Manual for Spot-Check Monitor 3. Short pressing power key to start NIBP measurement. 4. When the measurement is finished, the measured result and the corresponding emoji will be displayed on the screen, refer to the following figure. Figure 4.3 Screen Description: "...
Page 19
User Manual for Spot-Check Monitor means the host device is successfully connected with the device. "SYS 109 mmHg": it displays the measured value and the unit of systolic pressure. “DIA 84 mmHg”: it displays the measured value and the unit of diastolic pressure.
User Manual for Spot-Check Monitor During measurement, the testee should not talk, move the device, shake body or arm. For the same testee, the testee should wait for 3 minutes for another NIBP measurement. 4.2 SpO Measurement (Optional) Figure 4.4 SpO...
Page 21
User Manual for Spot-Check Monitor “%PI 4.1”: mark and value of Perfusion index. " ": heart beat icon. " ": plethysmogram. " ": pulse bar graph. Operation procedure: 1. Connect the SpO probe to the connector on the sensor connector.
User Manual for Spot-Check Monitor 2. If NIBP and SpO are measured simultaneously, then the NIBP measured result will be prior to be displayed for 10 seconds. CHAPTER 5 TECHNICAL SPECIFICATIONS 5.1 Blood Pressure Measurement 1. Blood pressure measuring range:...
User Manual for Spot-Check Monitor 3. Resolution: 1% 4. Low limit alarm value for SpO : 90%. Note: when the measured SpO ≤ 90%, then the over-limit SpO value blinks. 5.3 Pulse Rate Measurement (Optional) 1. Pulse Rate measuring range: 30bpm~240bpm 2 .
User Manual for Spot-Check Monitor 5. Effective radiated power : <1mW 5.5 Classification 1.Protection against electric shock: Class II equipment and internally powered equipment. 2.The degree of protection against electric shock: Type B applied parts 3. The degree of protection against harmful ingress of liquid: The equipment is IPX1 with protection against ingress of liquid.
User Manual for Spot-Check Monitor CHAPTER 6 MAINTENANCE AND SERVICE The Spot-Check Monitor is designed to serve for 5 years, it should be properly maintained to ensure its maximum performance and long service life. In addition to the warranty period, the manufacturer also offers long-term service for customers.
User Manual for Spot-Check Monitor 6.1.2 Battery Maintenance Only use the provided AC adapter to charge the built-in battery, if other charger is used, the device may be damaged. Whether the monitor is on or off, the built-in battery will be charged as long as the monitor is ...
User Manual for Spot-Check Monitor The accessories can not be entirely immerged into water, liquid or cleanser. Wipe the accessories clean with a mild cloth if it is dirtied. Wipe the accessories clean and keep it in the packaging for maintenance after using.
User Manual for Spot-Check Monitor CHAPTER 7 TROUBLESHOOTING Trouble Possible reason Solution Can not turn The built-in battery is Recharge it by connecting the power supply on the device exhausted adapter Incompatible accessories Remove the mis-connected parts and try are mis-connected to this again.
User Manual for Spot-Check Monitor CHAPTER 8 ERROR MESSAGE INTERPRETING Error Code Description ERR 01 Fail to inflate pressure to 30mmHg within 7 seconds (The cuff is not well-wrapped) ERR 02 Cuff pressure is over 295mmHg (Overpressure protection) ERR 03...
Page 30
User Manual for Spot-Check Monitor CHAPTER 9 PACKING LIST Item Description Quantity Check Spot-Check Monitor One piece User Manual One piece probe One piece Optional Charging cable One piece...
User Manual for Spot-Check Monitor Warranty Clause 1. We offer one year free repair for the main unit and 6-month for the accessories since purchasing. The invoice date is the starting date. 2. Make sure that the Warranty is sealed. Please present both the Warranty and the Invoice when you are requesting free repair.
User Manual for Spot-Check Monitor Appendix: Classification of Blood Pressure Level The below form is applicable to adult with age over 18 years. Blood Pressure Level (mmHg) (mmHg) Optimal blood pressure <120 <80 Normal blood pressure <130 <85 High normal blood pressure 130~139...