Page 1
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN Fingertip Puls Oximeter MD300 C63 User manual Start-up: summarised instructions 1. Before use, disinfect the device and the finger used for measured. 2. Insert your finger into the device until the end and nail towards the screen! 3.
Page 2
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN Thank you for choosing an Oxycure concentrator. The Oxycure range, from left to right Oxycure portable concentrators Oxycure portable concentrator – Inogen G4 Oxycure portable concentrator – Inogen G3 Oxycure portable concentrator – Zen-O lite Oxycure portable concentrator –...
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN OPERATOR’S MANUAL V1.0C63 MD300C63 Fingertip Pulse Oximeter General Description Oxygen Saturation is a percentage of Oxyhemoglobin (HbO2) capacity, compounded with oxygen, by all combinative hemoglobin (Hb) capacity in blood In other words, it is consistency of Oxyhemoglobin in blood.
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN by the symbol. Prolonged use or the patient’s condition may require changing the sensor site periodically. Change sensor site and check skin integrity, circulatory status, and correct alignment at least every 4 hours. 10 Inaccurate measurements may be caused by autoclaving, ethylene oxide sterilizing, or immersing the sensors in liquid may cause inaccurate readings.
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN After turning on the Oxim eter, each tim e you press the pow er sw itch, the Oxim eter w ill sw itch to another display m ode, there are 6 display m odes show n as follow s: When you press the power switch for a long time (more than one second), the brightness of the Oximeter will be changed by degrees, there are 10 levels on brightness;...
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN 2. Thread thicker end of the lace through the threaded end before pulling it tightly. Maintenance and Storage 1. Replace the batteries in time when low voltage lamp is lighted. 2. Clean surface of the fingertip Oximeter before it is used in diagnosis for patients. 3.
Page 8
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN Width: 32mm Height: 37mm Weight: 33g (without batteries) 6. Environment Requirements: Operation Temperature: 5~40℃ Storage Temperature: -20~55℃ Ambient Temperature: <80% in operation, no condensation. <93% in storage, no condensation. 7. Declaration: EMC of this product complies with IEC60601-1-2 standard. 8.
D.SPEC.05.10 Pulse oxymètre MD300-C63 - Mode d'emploi_EN 1. No battery or low power of 1. Replace batteries. The Oximeter battery.l 2. Reinstall batteries. can not be 2. Batteries might be installed 3. Contact with local customer powered on. incorrectly service centre. 3.
Need help?
Do you have a question about the MD300 C63 and is the answer not in the manual?
Questions and answers