MANUALE DI PROGRAMMAZIONE PANNELLO A-POOL TOP EVO PH-CL PROGRAMMING INSTRUCTIONS A-POOL TOP EVO PH-CL PANEL A-POOL TOP EVO PH-CL ITALIANO pag. ENGLISH pag. ADSP7000712 10/10/2016 Rev. 1.0 1/52...
Pannello di controllo e regolazione ITALIANO 1. INTRODUZIONE Il pannello A-POOL TOP EVO PH-CL permette di effettuare un controllo dei parametri dell’acqua attraverso un dosaggio ON/OFF o proporzionale del cloro residuo libero con range 0-10.00 ppm. Il pannello è composto: ...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO CARATTERISTICHE IDRAULICHE POMPA HC151 Portata massima @ Frequenza Volume Potenza Misure Connessioni massima pressione colpi (max) per colpo Assorbita (max) tubo testa pompa MODELLO per min. ml / colpo watt model PP ½”...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO Flusso (a scelta blocco dei relè) Il Relè 2 è programmabile per la segnalazione di ogni singolo allarme. Controllo delle attivazione di tutti gli allarmi Statistiche Controllo del tempo totale di funzionamento dei Relè 1 e 2 sul dosaggio...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 3. MORSETTIERA ATTENZIONE: Prima di eseguire interventi di manutenzione sull’apparecchio, scollegare sempre l’alimentazione. MORSETTIERA STRUMENTO AE START CLORO INGRESSO DESCRIZIONE COSA COLLEGARE Alimentazione 230 VAC Cavo di alimentazione 4-5 / 6-7 Uscite Relè...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO MORSETTIERA POMPA HC151 INGRESSO DESCRIZIONE COSA COLLEGARE Ingresso per collegare un segnale in corrente 0÷20mA, proveniente ad esempio da uno strumento. FLUSH Ingresso per collegare il sensore di flusso. PULSE Ingresso per collegare il contatore lancia impulsi.
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 4. CONNESSIONI PANNELLO FLUSSO - STRUMENTO AE START PHRX FLUSSO - STRUMENTO PHRX – STRUMENTO CLORO STRUMENTO AE START – POMPA HC151 Connettere l’uscita mA dello strumento AE START all’ingresso mA (n.8 vedi 3.4) della pompa HC151 rispettando la polarità:...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 5. INTERFACCIA UTENTE INTERFACCIA UTENTE AE START Il pannello di comando è composto: Display Alphanumerico LCD 2x16 retroilluminato 4 tasti: Enter, Esc, Up, Down, INTERFACCIA UTENTE HC151 Il pannello di comando è composto: ...
Page 11
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 2. Premere il tasto UP fino ad arrivare al menu: CALIBRAZIONE Cal. Sonda Inserire sonda nella soluzione tampone Zero: 7.00 pH calibrazione del 1’ punto (Offset) Effettua la calibrazione dello zero della sonda, ovvero si immerge la sonda in una Read: 7.01 pH...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO PROGRAMMAZIONE MISURAZIONE PH 1. Dal menu Utente: MENU UTENTE LUNGO Default password: 0000 PASSWORD LUNGO 2. Premere il tasto UP fino ad arrivare al menu : Premere il tasto ENT –...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 6.2.1 Modalità ON-OFF La programmazione del setpoint ON-OFF prevede che il relè associato si chiuda (se N.A) fino a che non venga raggiunto il valore SP programmato. In questa modalità sarà possibile, inoltre, impostare un ritardo iniziale di attivazione, un valore di isteresi sul setpoint, e un ritardo finale di disattivazione.
Page 14
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 2. Premere il tasto UP fino ad arrivare al menu: CALIBRAZIONE Cal. Sonda Pt-Cu Si può scegliere se calibrare lo zero della Sonda. Calibraz. Zero? Nel caso in cui si scelga “no”, verrà assunto come zero Si/No quello della precedente calibrazione (se già...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO PROGRAMMAZIONE USCITA mA CLORO 1. Dal menu Utente: MENU UTENTE LUNGO Default password: 0000 PASSWORD LUNGO SETUP 2. Premere il tasto ENT e successivamente il tasto UP fino ad arrivare al menu:...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 2. Premere il tasto ENT e successivamente il tasto UP fino ad arrivare al menu: USCITA mA Premere il tasto Ent per selezionare il valore pH a 4 mA 0.00 pH cui associare l’uscita mA.
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO PROGRAMMAZIONE ALLARMI – RELE2 NC (NORMALMENTE CHIUSO) 1. Dal menu Utente: MENU UTENTE LUNGO Default password: 0000 PASSWORD LUNGO SETUP 2. Scorrere con il tasto Up fino alla voce Impostazioni Relè e premere il tasto ENT fino ad arrivare al Impostare NC con i tasti Up/Down 3.
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO PROGRAMMAZIONE ALLARMI - FLUSSO 4. Dal menu Utente: MENU UTENTE LUNGO Default password: 0000 PASSWORD LUNGO SETUP 5. Premere il tasto ENT e successivamente il tasto UP fino ad arrivare al menu ALLARMI 6.
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 7. PROGRAMMAZIONE POMPA HC 151 PROGRAMMAZIONE DEFAULT POMPA HC151 La programmazione della pompa HC151 è così impostata: Modalità di funzionamento: mA Range di misura: 4÷20 mA Frequenza di dosaggio 4mA: 0% ...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO Con i tasti Up e Down si seleziona ALLARME l’allarme LIVELLO/FLUSSO/IMPULSI/OFA/RANGE Livello Con i tasti Up e Down si seleziona se il contatto è AL. LIVELLO normalmente aperto (N.O.) o normalmente chiuso (N.C.).
Page 21
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO MODE 5. Premere il tasto ENT Con i tasti Up e Down si impostano i valori L1 e mAL1:<L1> P:<PL1> % PL1 (portata L1) e L2 e PL2 (portata L2). L1 e L2 sono impostabili tra 4…20mA a passi di 0,1 mA.
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO 8. MANUTENZIONE SONDA Pt-Cu OVERVIEW INSTALLAZIONE Fissare le sonde in posizione verticale come indicato in Figura 1/2 e raccordare la parte idraulica. Collegare i fili della sonda all’apparato rispettando rigorosamente la polarità indicata dal colore del filo MARRONE/PLATINO (PT) e AZZURRO/RAME (CU).
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO MANUTENZIONE Dopo un periodo di funzionamento della sonda, se risulta difficile effettuare la taratura, occorre procedere alla pulizia dell’elettrodo di rame come descritto di seguito: Chiudere il flusso d’acqua.
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO PROCEDURA PULIZIA FILTRO PROCEDURA PULIZIA ELETTRODO ADSP7000712 10/10/2016 Rev. 1.0 24/52...
A-POOL TOP EVO PH-CL Pannello di controllo e regolazione ITALIANO TABELLA COMPATIBILITA’ CHIMICA La seguente Tabella è uno strumento da utilizzare a titolo orientativo. Modifiche nella composizione del fluido trasportato o condizioni di servizio particolari possono provocare una riduzione della resistenza dei materiali.
Page 26
INDEX INTRODUCTION ............................28 PANEL COMPOSITION ....................28 WHAT’S IN THE BOX ..................... 28 AE START TECHNICAL FEATURES ................28 HC 151 TECHNICAL FEATURES (OPTIONAL) .............. 28 HC151 HYDRAULIC FEATURES (OPTIONAL) .............. 29 GENERAL FEATURES ..........................29 AE START CLHORINE FUNCTIONING FEATURES ............29 AE START PH FUNCTIONING ..................
Page 27
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH LEVEL ALARM PROGRAMMATION ................43 mA WORKING MODE PROGRAMMATION ..............44 Pt-Cu PROBE MAINTENANCE ....................... 46 OVERVIEW ........................46 INSTALLATION ....................... 46 MAINTENANCE....................... 47 TECHNICAL FEATURES ....................47 CLEANING FILTER PROCEDURE ................. 48 CLEANING ELECTRODE PROCEDURE ................
Page 28
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 1. INTRODUCTION The A-POOL TOP EVO PH-CL controls water parameters with ON/OFF or proportional control of free Chlorine from 0.00-10.00 ppm. The panel is composed: n.1 AE START pH controller to control pH ...
Page 29
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH HC151 HYDRAULIC FEATURES (OPTIONAL) Strokes Max flow rate @ Frequency Volume Consumption Size Head pump MODEL Max pressure (max) per stroke (max) tubing connections per min. ml / stroke watt model PP ½”...
Page 30
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH Relay n.2 selectable on each alarm signal. Statistics of the alarms, of the number of set point activations Statistics and of the operating time of each relay AE START PH FUNCTIONING Measure 0.00-14.00 pH...
Page 31
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 3. TERMINAL BLOCK CAUTION: Always disconnect power when servicing the unit. AE START CHLORINE TERMINAL BLOCK INPUT DESCRIPTION WHAT CONNECT 80-265 VAC Power Supply Power Supply cable 4-5 / 6-7...
Page 32
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH HC 151 TERMINAL BLOCK INPUT DESCRIPTION WHAT CONNECT Input to connect a 0÷20mA current signal that comes for example a controller. FLUSH Input to connect a flow sensor. PULSE Input to connect a water meter.
Page 33
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 4. PANEL CONNECTIONS AE START PHRX CONTROLLER FLOW SENSOR FLOW - AE START PHRX CONTROLLER – AE START CL CONTROLLER AE START CONTROLLER – HC 151 METERING PUMP Connect mA output of AE START to mA input (n.8 vedi 3.4) of HC151 matching polarity ...
Page 34
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 5. USER INTERFACE AE START USER INTERFACE User interface: Back light alphanumeric 2x16 LCD 4 keys: Enter, ESC Up, Down, HC151 USER INTERFACE User interface: Back light alphanumeric 2x16 LCD ...
Page 35
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 2. Press the UP key until menu: CALIBRATION Probe Cal. Insert the probe in the buffer solution for calibration 1 Zero: 7.00 pH 'point (Offset) Perform zero calibration of the probe, or you immerse pH probe in a solution with pH = 7.00 theoretical...
Page 36
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH PH MEASURE 1. From User Menu: USER MENU LONG Default password: 0000 PASSWORD LONG 3. Press the UP key until menu: Press ENT key – For scrolling values, you can use...
Page 37
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 6.2.1 ON-OFF Mode With ON OFF Mode programming, the chosen relay closes (if Normally Open) until reaching the programmed set-point. In this mode, it is also possible to set an initial delay on activation, an hysteresis value on set-point, and set a final delay on deactivation.
Page 38
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 2. Press the UP key until menu: CALIBRATION Probe Cal. Pt-Cu You can choose to calibrate the zero of the probe. Cal. Zero? In case you choose "no", it will be assumed as zero that...
Page 39
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH OUTPUT mA AE START CHLORINE PROGRAMMATION 1. From User menu: USER MENU LONG Default password: 0000 PASSWORD LONG SETUP 2. Press ENT and then press the UP key until menu: mA OUTPUT Select ppm value to associate the mA output by 10.00...
Page 40
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 2. Press ENT and then press the UP key until menu: mA OUTPUT Select ppm value to associate the mA output by 0.00 pH ENT key. 20 mA 14.00 pH Press Up and Down keys to set value.
Page 41
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH ALARMS PROGRAMMATION – RELAY2 NC (NORMALLY CLOSED) 1. From User menu: USER MENU LONG Default password: 0000 PASSWORD LONG SETUP 2. Press the UP key until Settings Relay menu and press ENT key until menu: Set NC by Up/Down keys 3.
Page 42
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH FLOW ALARM PROGRAMMATION 1. From User menu: USER MENU LONG Default password: 0000 PASSWORD LONG SETUP 2. Press ENT and then press the UP key until menu: ALARMS 3. Press ENT key 4.
Page 43
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 7. HC151 PROGRAMMATION DEFAULT PROGRAMMATION Default HC151 programmation is set: Working mode: mA Measure Range: 4÷20 mA 4mA dosage frequency: 0% 20mA dosage frequency: 50% Below L1 (4mA): disable dosage ...
Page 44
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH ALARM Select alarm by pressing the Up and Down keys. LEVEL / FLOW / PULSES / OFA / RANGE Level Select type of contact NO (normally open) or NC (Normally LEVEL ALARM closed) N.O./N.C.
Page 45
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 3. Press ENT key 4. Press UP key to select: MODE 5. Press ENT key Use the Up and Down keys to set the values L1, and PL1 mAL1:<L1> P:<PL1> % (range L1) and L2 and PL2 (range L2).
Page 46
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH 8. Pt-Cu PROBE MAINTENANCE OVERVIEW INSTALLATION Fix the probe in vertical position as shown in picture 1/2 connect the hydraulic connections. Connect the probe cables by strictly respecting the polarity indicated from the cable color BROWN/PLATINUM PT AND BLEU/COPPER CU.
Page 47
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH MAINTENANCE After a working period of the probe if it became difficult to calibrate the probe, it’s needed to proceed with the electrode cleaning as follows: Close the water flow ...
Page 48
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH CLEANING FILTER PROCEDURE CLEANING ELECTRODE PROCEDURE CHEMICAL COMPATIBILITY TABLE The following Table must be used as an indicative instrument. Modifications in the transported fluid composition or particular service conditions can reduce the resistance of the materials.
Page 49
A-POOL TOP EVO PH-CL Control and regulation panel ENGLISH Product Formula Ceram. PVDF Hastel. PTFE EPDM (Viton) (Dutral) Acetic Acid, Max 75% CH3COOH Concentrated hydrochloric acid Hydrofluoric acid 40% H2F2 Phosphoric acid, 50% H3PO4 Nitric acid, 65% HNO3 Sulphuric acid 85% H2SO4 Sulphuric acid 98.5%...