Trek 610D Operator's Manual

High-voltage supply/amplifier/controller

Advertisement

OPERATOR'S MANUAL
MODEL 610D
HIGH-VOLTAGE
SUPPLY/AMPLIFIER/CONTROLLER
TEL: 1 (716) 438-7555
TREK, INC.
190 Walnut Street
FAX: 1 (716) 201-1804
Lockport, NY 14094-3710
NTERNET: www.trekinc.com
E-MAIL: sales@trekinc.com
Model 610D Operator's Manual Rev. B6
Part Number: 23120
0324/JNC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 610D and is the answer not in the manual?

Questions and answers

Summary of Contents for Trek 610D

  • Page 1 OPERATOR’S MANUAL MODEL 610D HIGH-VOLTAGE SUPPLY/AMPLIFIER/CONTROLLER TEL: 1 (716) 438-7555 TREK, INC. 190 Walnut Street FAX: 1 (716) 201-1804 Lockport, NY 14094-3710 NTERNET: www.trekinc.com E-MAIL: sales@trekinc.com Model 610D Operator’s Manual Rev. B6 Part Number: 23120 0324/JNC...
  • Page 3 Rev. 01 Q-Form-CE-003 Declaration of Conformity Trek, Inc. 11601 Maple Ridge Road Medina, New York 14103 Tel: 585/798-3140 Fax: 585/798-3106 Name and address of manufacturer: Introducer of product to the market: Declare under our sole responsibility that the product, Product Name:...
  • Page 4 Rev. 01 Q-Form-CE-003...
  • Page 5 Thank You Thank you for buying a Trek instrument. This instrument has been designed and built to high standards to give you years of trouble-free service. If you have any questions, please feel free to contact your Trek Representative at: Write: TREK, INC.
  • Page 7: Table Of Contents

    Operating the Model 610D as a High-Voltage Amplifier ... III-11 Operating the Model 610D as a Current Supply ....III-12 Operating the Model 610D as a Transconductance Amplifier .
  • Page 8 Table of Contents Section III Operation (cont.) III-16 Setting a Voltage Limit ......III-17 Remotely Turning On and Off the High-Voltage Output .
  • Page 9: Safety

    Safety Review the following safety precautions to maintain safety and prevent damage to the instrument or equipment connected to it. The safety features of this instrument may be ineffective if the equipment is not operated in the manner stated in this manual. Refer all maintenance procedures to qualified personnel.
  • Page 10 Safety Safety Precautions (cont.) Do Not Operate Without Covers To avoid electric shock or fire hazard, do not operate this instrument with the covers removed. Use Proper Fuses To avoid fire hazard, use only the fuse type and rating specified for this instrument. Indoor Use Only This instrument is intended for indoor use only.
  • Page 11 Safety Safety Terms and Symbols Terms in the Manual These terms may appear in this manual: Warning statements identify conditions or practices that could result in Warning: injury or loss of life. Caution: Caution statements identify conditions or practices that could result in damage to this product or other equipment.
  • Page 12 Safety...
  • Page 13: Preface

    Preface This manual provides user information for the Model 610D High-Voltage Supply/Amplifier/Controller. It contains the following chapters and appendixes: contains a brief product description, specifications, and an • General Information incoming confidence test that can be used to verify the instrument was not damaged during transit.
  • Page 14 viii...
  • Page 15: Section I General Information

    This instrument is not rated for use in an explosive environment. DO NOT use it in an explosive environment or an explosion may result. This manual provides instructions to install and operate the Trek Model 610D High-Voltage Supply/Amplifier/Controller. We recommend you take the time to read this manual to take full advantage of the features and benefits of the instrument.
  • Page 16: Introduction

    I(t), or a specific current path, I(r). When the load includes several current paths, only one is closely regulated. The Model 610D can be operated on a bench top or, with optional hardware, in a standard 19-inch rack. I - 2...
  • Page 17: Specifications

    General Information Specifications All specifications are with no load unless otherwise specified. Features High-Voltage Switch A three-position switch to select ON, OFF, or REMOTE. Mode Switch A three-position switch to select either the Supply, Amplifier, or Controller mode of operation. Supply Mode Voltage Control Range Selection A two-position switch to select...
  • Page 18 General Information Specifications (cont.) Features (cont.) Front Panel Display A 3 ½-digit LED display can be selected to indicate the voltage output or the current output. Range Voltage 0 to ±1 kV or 0 to ±10 kV, switch selectable. Current 0 to ±199.9 µA or 0 to ±1999 µA, switch selectable.
  • Page 19 General Information Specifications (cont.) AS A HIGH-VOLTAGE SUPPLY Output Voltage Range 0 to +1 kV, 0 to -1 kV, 0 to +10 kV, or 0 to -10 kV, switch selectable and adjustable using a precision potentiometer with a dial. Resolution 1 kV range 1 volt.
  • Page 20 General Information Specifications (cont.) AS A CURRENT SUPPLY 0 to 200 µA or 0 to 2000 µA, switch Output Current Range selectable and adjustable using a precision potentiometer with a dial. Resolution 200 µA range 0.2 µA. 2000 µA range 2 µA.
  • Page 21 General Information Specifications (cont.) AS A HIGH-VOLTAGE AMPLIFIER AND CONTROLLER (cont.) DC Voltage Gain Accuracy Better than 0.3% of full scale (Controller mode Gain Accuracy is dependent on user-specified components). 0 to ±2000 µA DC or peak AC, adjustable Compliance Current Range using a precision potentiometer with a dial.
  • Page 22 General Information Specifications (cont.) AS A TRANSCONDUCTANCE AMPLIFIER AND CONTROLLER 0 to ±200 µA or 0 to ±2000 µA DC or Output Current Range peak AC, switch selectable. Input Voltage Range 0 to ±10 V DC or peak AC. Transconductance Gain 200 µA range 20 µA/V.
  • Page 23 General Information Specifications (cont.) VOLTAGE AND CURRENT MONITORS (cont.) Current Monitor 1 V/200 µA Ratio Noise Less than 30 mV p-p. DC Gain Accuracy Better than 0.1% of full scale as referred to the high-voltage output. Offset Voltage Less than 10 mV. Output Impedance 1 kΩ, nominal.
  • Page 24 General Information Specifications (cont.) Certification and Compliance Certification TREK, INC. certifies that each Model 610D is tested and calibrated to specifications using measurement equipment traceable to the National Institute of Standards and Technology. Low Voltage Safety Compliance (EN 61010-1) Installation Category CAT II: Local-level mains, appliances, portable equipment.
  • Page 25: Incoming Inspection

    MONITOR OUTPUT connector would constitute a reasonable incoming confidence test. Warning: Do not plug in the Model 610D or turn it on until instructed to do so. To do so before the appropriate point in time could result in an electrical shock and/or damage to the instrument.
  • Page 26 The HIGH VOLTAGE OUTPUT connector carries high voltage. Warning: Do not touch the HIGH VOLTAGE OUTPUT connector or the load circuit while the Model 610D is operating. Always turn off the Model 610D before making changes to the load connections. Turn the COMMAND/OFFSET fully clockwise.
  • Page 27: Section Ii Installation

    19-inch rack. See Appendix A, Accessories, for information concerning the rack mount hardware. The Model 610D is air cooled. Allow approximately 25 mm (1 inch) of free air space around the vent holes in the top cover of the instrument. Allow approximately 50 mm (2 inches) of free air space around the fan on the rear panel.
  • Page 28: Load Connection

    The HIGH VOLTAGE OUTPUT connector carries high voltage. Do not touch the HIGH VOLTAGE OUTPUT connector or the load circuit while the Model 610D is operating. Always turn off the Model 610D before making changes to the load connections. The maximum possible voltage at the HIGH VOLTAGE OUTPUT connector Note: is ±12 kV.
  • Page 29 Installation Input Connection (cont.) Figure 2-2: Inverting Amplifier Figure 2-1: Noninverting Amplifier Figure 2-3: Differential Amplifier II - 3...
  • Page 30 Installation Monitor Output Connection The V MONITOR OUTPUT connector on the rear panel is a buffered output providing a low-voltage replica of the high-voltage output. 1 V at this connector represents 1000 V at the HIGH VOLTAGE OUTPUT. Connect a monitoring device, such as an oscilloscope, to this connector to monitor the high-voltage output.
  • Page 31: External Control Connection

    The EXT. CONTROL connector on the rear panel of the instrument is for connection of a remote switch to turn on and off the high-voltage output of the Model 610D when the HV switch on the front panel is in the REMOTE position.
  • Page 32: Digital Enable Connection

    Installation Digital Enable Connection The DIGITAL ENABLE connector on the rear panel of the instrument is a BNC for connection of a remote device to provide fast control of the high-voltage output. This feature does not turn off the high-voltage completely, but reduces the output voltage to below 100 volts.
  • Page 33: Section Iii Operation

    Front Panel Features Figure 3-1: Model 610D Front Panel (features 1-3) 1. FUNCTION Switch: This switch selects whether the Model 610D will operate as a supply, as an amplifier, or as a controller. 2. HV Switch and Indicator: This switch turns on and off the high-voltage output.
  • Page 34: Front Panel Features

    This 10-turn dial sets the desired output voltage or 5. Command/Offset Dial: current when the Model 610D is operated in the Supply mode. It is also adjusts the level of the output offset when Model 610D is operated in the Amplifier or Controller modes.
  • Page 35 8. µA/kV Range Switch: This switch selects the output (voltage or current) range when the Model 610D is operated in the Supply mode. It also sets the gain and offset range when the Model 610D is operated in the Amplifier or Controller modes.
  • Page 36 Operation Front Panel Features (cont.) Figure 3-4: Model 610D Front Panel (features 12-15) Meter Section This switch selects the full scale range for the digital 12. µA/kV Range Switch: panel meter. It selects a 1 kV or 10 kV full scale range when the V/I switch is in the voltage (V) position.
  • Page 37: Rear Panel Features

    Operation Rear Panel Features Figure 3-5: Model 610D Rear Panel (features 1-6) 1. I MONITOR OUTPUT Connector: This BNC provides a buffered, low-voltage representation of the total current, I(t), or returned current, I(r), depending upon the position of the I(t)/I(r) switch to the right of this connector.
  • Page 38 Operation Rear Panel Features (cont.) Figure 3-6: Model 610D Rear Panel (features 7-12) 7. HIGH VOLTAGE OUTPUT Connector: This connector is for connection of the load device using the high-voltage output cable assembly provided. 8. I(r) Binding Post: This binding post is a return point for a load device that has an ungrounded return path.
  • Page 39: Normal Operation

    Model 610D is operating. Always turn off the Model 610D before making changes to the load connections. The Model 610D can be operated in one of six modes: as a high-voltage supply, as a high-voltage amplifier, as a current supply, as a transconductance amplifier, as a high-voltage controller, and as a transconductance controller.
  • Page 40 Warning: The HV OUT connector carries high voltage. Do not touch the HV OUT connector or the load circuit while the Model 610D is operating. Always turn off the Model 610D before making changes to the load connections. III - 8...
  • Page 41: Operating The Model 610D As A High-Voltage Amplifier

    See “Input Connection” on page II-2 for information on how to wire the input connector to obtain the different configurations. As a Noninverting Amplifier the Model 610D will produce an output voltage which is 100 or 1000 times greater (depending upon the gain selected) than the signal applied to the INPUT SIGNAL receptacle.
  • Page 42 The HV OUT connector carries high voltage. Do not touch the HV Warning: OUT connector or the load circuit while the Model 610D is operating. Always turn off the Model 610D before making changes to the load connections. If an offset voltage is desired:...
  • Page 43: Operating The Model 610D As A Current Supply

    Normal Operation (cont.) Operating the Model 610D as a Current Supply When the Model 610D is operated as a current supply, the operator sets an output current using the Command/Offset controls. Ensure that the Polarity switch in the COMMAND/OFFSET section of the front panel is in the OFF position and that the Command/Offset Dial is turned fully counterclockwise.
  • Page 44: Operating The Model 610D As A Transconductance Amplifier

    “0 - 2000 µA” position, each complete turn of the dial represents a 200 µA change to the output current. The Model 610D is now operating as a current supply and delivering the current commanded by the Command/Offset controls to the HV OUT connector.
  • Page 45 Place the HV switch in the ON position. Apply a 0 to ±10 V DC or peak AC signal to the AMP INPUT receptacle. The Model 610D is providing the output current commanded to the HV OUT connector. The HV OUT connector carries high voltage. Do not touch the HV Warning: OUT connector or the load circuit while the Model 610D is operating.
  • Page 46: The Compliance Feature

    This feature is used to limit the output of the Model 610D to within a safe operating range for the load device. For example, when in the CURRENT mode, voltage can be limited so as not to exceed the voltage rating of the load device;...
  • Page 47: Setting A Current Limit

    Example: The Compliance controls are set for a 700 µA current limit. If the Model 610D is set up for an output voltage of 500 V and it is driving a 1 MΩ load, the current flowing through the load is 500 µA. In this instance, the current flowing through the load does not exceed the current limit value set by the Compliance controls and the output voltage is not restricted.
  • Page 48: Setting A Voltage Limit

    E I R 500 A µ Ω 2500 V The Model 610D will automatically restrict the output current to 400 µA in order to hold the output voltage level at the compliance limit set for 2000 volts. 2000 V 400 A µ...
  • Page 49: Remotely Turning On And Off The High-Voltage Output

    Operation Normal Operation (cont.) Remotely Turning On and Off the High-Voltage Output When the HIGH VOLTAGE Switch is in the REMOTE position, the high-voltage output can be turned on and off by a remote device connected to the EXT. CONTROL input on the rear panel of the unit (See page II-5).
  • Page 50: Monitoring The Load Current

    Operation Normal Operation (cont.) Monitoring the Output Voltage (cont.) Rear Panel BNC V MONITOR OUTPUT connector: A buffered, low-voltage replica of the output voltage is provided at the V MONITOR OUTPUT connector. 1 V at this connector represents 1000 V at the HIGH VOLTAGE OUTPUT connector.
  • Page 51 (ungrounded) load path using the I(t)/I(r) switches. I(r) current is a component of total load current, I(t). I(t) (total load current) refers to all of the load current which is returned to the 610D except those load currents which are returned to the I(s) terminal. Total load current, I(t), is monitored by the 610D and provides a means for close regulation and monitoring of the total load current using the I(t) and I(r) switches.
  • Page 52 I(t) current and the I(s) current exceeds the current sourcing capability of the high voltage output. The output current of the 610D is regulated on the basis of the monitored current, I(t) or I(r), it is therefore possible for the additional I(s) current to take the instrument out of (current) regulation.
  • Page 53: Section Iv Maintenance

    Observe the following safety precautions when performing maintenance procedures on the Model 610D: Always turn off the Model 610D and disconnect it from its power source before cleaning or inspecting it. Failure to observe this precaution could result in an electrical shock.
  • Page 54: Repairs

    The warranty is voided if the instrument is serviced within the warranty Note: period by anyone other than TREK, INC. or one of its authorized Trek Service Organizations. In the event of a malfunction, and the instrument must be returned for repair: Notify the Customer Service Group at TREK, INC., giving full details about the...
  • Page 55: Servicing The Fuses

    The line receptacle for the 610D contains a fuse holder that contains two IEC 5 mm x 20 mm, time-lag (T) fuses. The Model 610D can be configured for different AC line voltages. Please refer to the chart below for proper fuse ratings.
  • Page 56 Maintenance IV - 4...
  • Page 57 Appendix A Accessories Included Accessories Item Part Number Operator’s Manual ......23120 High-Voltage Output Cable Assembly .
  • Page 59 Appendix B Warranty Statement Instruments sold by TREK, INC. (hereinafter called the “Company”) are warranted only as stated below: Subject to the exceptions and upon the conditions specified below, the Company agrees to correct, either by repair, or in the Company’s sole discretion, by replacement, any defect of...
  • Page 61 Please go to our web site: www.trekinc.com for a complete list of our sales and service representatives and distributors located in the United States and throughout the world. Trek Contact Information: TREK, INC. 190 Walnut Street Lockport, NY 14094-3710 USA...