Contech CCS Series Operating Manual

Electronic weighing scale

Advertisement

Quick Links

ELECTRONIC WEIGHING SCALE
CCS - SERIES
OPERATING MANUAL
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CCS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Contech CCS Series

  • Page 1 ELECTRONIC WEIGHING SCALE CCS - SERIES OPERATING MANUAL ®...
  • Page 2: Table Of Contents

    CONTENTS Introduction Crane scale sketch Installation Operation of the Scale Print Option Bi-directional RS-232 interface Storage of Weights in Memory Auto Power Off Piece Counting Mode Set Point Facility Operating in Tare / Zero Mode Set up Function...
  • Page 3: Introduction

    INTRODUCTION We thank you for choosing series weighing scale for your weighing needs. These scales use some of the latest and most advanced computing powers to give maximum flexibility and utility to the user. Features: weighing unit gram / kilo gram. Feather touch membrane keyboard.
  • Page 4: Crane Scale Sketch

    Power Stable Stable HOLD MODE MODE HOLD TARE ENT. FRONT VIEW R.H SIDE VIEW R.H SIDE VIEW REAR VIEW REAR VIEW CRANE SCALE SKETCH...
  • Page 5: Installation

    INSTALLATION 1. Unpacking: Unpack the balance. Save the packing container for future use. 2. Electrical Requirements: The balance requires very stable power. It works on 230V AC supply with PROPER EARTHING. The power outlet used for the balance should not be shared with any other devices which draws current in inconsistent manner like Air Conditioner or Refrigerator etc.
  • Page 6: Operation Of The Scale

    OPERATION OF THE SCALE 1) FOR CHANGING WEIGHING UNITS. MODE Press key, the scale will show for some time and will display the current weighing unit, say grams keys to change the mode and Press key to select ENTER TARE Press key to discard the changes.
  • Page 7 OPERATION OF THE SCALE Press key once again, the scale will show where DD is the current date. Use keys to change ENTER date and press key to store the date. ZERO Press key to skip date entry. The scale will display where MM is the current month.
  • Page 8 OPERATION OF THE SCALE ENTER Press key to change the time or TARE Press key to quit time entry. Press key, the scale will show, ENTER where xx is the hour. Use key to change hour. ZERO ENTER Press key to save. Press key to skip hour entry.
  • Page 9: Print Option

    PRINT OPTION CT/CP series weighing scales can be attached to a serial printer for your printing needs. Print out can be programmed to suit most of the printing requirements. Note that the printer should have a serial port and baud rate of the scale and printer should be same.
  • Page 10 PRINT OPTION P-TYPE: Print type (Horizontal or Vertical) – Horizontal Details will be printed horizontally. Sr.No. Date Time Weight 12.05.2002 13:25:00 4.545 kg 12.05.2002 13:27:05 4.234 kg – Vertical Details will be printed vertically in a slip form. Sr.No. : 001 Date : 12.05.2002 Time : 13:25:00 Weight : 4.545 kg...
  • Page 11: Bi-Directional Rs232-Interface

    BI-DIRECTIONAL RS232-INTERFACE Bi-directional RS-232 interface is provided in these scales to communicate with devices like computer, printer etc. The interface is provided through a nine pin D- type connector provided in the side connector plate of the scale. Connections are as below.
  • Page 12: Storage Of Weights In Memory

    STORAGE OF WEIGHTS IN MEMORY Upto 100 weights can be stored in memory and recalled if required. The scale also computes the total weight of all the weights in memory. To use this option, set ACCU function to ON in SETUP functions. See relevant section. a) Clear weights in memory.
  • Page 13 STORAGE OF WEIGHTS IN MEMORY c) Recalling weights from memory. Press Immediately Press key, the scale will display Press key, the scale will display followed by the stored weight WWWW.WW i) Press keys to see weights stored. ii) Press TARE key to end weight view and display total weight.
  • Page 14: Auto Power Off

    AUTO POWER OFF CCS series weighing scales have a built in auto power off facility, where in the displays will be switched off , if any keys are not operated for approx. 5 minutes. This will reduce power consumption and if the scale is being used with battery, it can enhance the discharge time of battery.
  • Page 15: Piece Counting Mode

    PIECE COUNTING MODE Contech CCS series scales can be used for piece counting purposes. Piece calibration of 25 items can be stored in memory. Accuracy of piece counting depends on the uniformity in weight of the items and the sample size used for piece calibration.
  • Page 16 PIECE COUNTING MODE Piece Calibration Select proper piece counting memory as mentioned above. TARE Make the Weight read zero by pressing the key. Weight of any container/bags used should also be made zero. Keep known number of pieces on the pan. Press key., the scale will display ENTER...
  • Page 17: Set Point Facility

    SET POINT FACILITY This facility enables the user to set up to 3 weights for comparison with the current weights to activate different events. This feature is controlled by 3 SETUP functions. 1. Fill - Make it FL-on 2. SEt Pt. - Make it SET-1, SET-2 3.
  • Page 18 SET POINT FACILITY The scale will show (If fill option is on and limit is set to SET-2 or above) For some time and will display XXXX.XX Where XXXX.XX is the current set limit. keys to change the limit. To discard changes, Press ZERO key.
  • Page 19 SET POINT FACILITY Set Point 1: User can set a weight any where in the range of the scale. Depending on the weight on the pan, the following events occur. Buzzer will work only in case of models where buzzer is provided. All outputs are TTL outputs provided additionally, if needed. F-Type Weight <...
  • Page 20 SET POINT FACILITY F-Type Weight within Weight = lower or Weight is beyond Set Limit Upper limit. the limits. Type 2 Buzzer OFF Buzzer ON Buzzer OFF O/p 1 low, if weight is more than first limit. O/p 2 low, if weight is more than second limit. O/p 1 high, if weight is less than or equal to first limit, O/p 2 high, if weight is less than or equal to second limit.
  • Page 21: Operating In Tare / Zero Mode

    OPERATING IN TARE ZERO MODE SET POINT FACILITY TARE-ZERO mode, scale can be operated in its simplest mode. In this mode, TARE Press to make the weight zero. ZERO Press key to make weight zero. Press key to toggle between Gross and Net mode.
  • Page 22 SETUP FUNCTIONS SETUP functions control the basic operation of the balance. There more than 20 parameters, which can be set by the user to suit the requirements. The following are these parameters. MENU NAME FUNCTION OPTIONS DESCRIPTION Factory setting To select factory set parameters. Piece counting modes PArt-1 To select single piece counting memory.
  • Page 23 SETUP FUNCTIONS - Weight storage mode. AC-nO Weight storage disabled AC.YES Weight storage enabled - Fill mode option fL-Off Fill mode disabled fL.On Fill mode enabled - Carat weighing Crt-Off Carat weighing disabled Crt.On Carat weighing enabled - Litre weighing Lt1-Off Litre mode disabled Lt1.On...
  • Page 24 SETUP FUNCTIONS - Title printing. TLE-Off Title printing disabled TLE.On Title printing enabled Select printing mode. P.tYPE1 Horizontal Printing mode P.tYPE2 Vertical Printing mode Select print formats. Prf-1 Only weight Prf-2 Sr.no. Weight Prf-3 Sr.no., Date, Weight Prf-4 Sr.no., Time, Weight Prf-5 Sr.no., Date, Time, Weight Select S type...
  • Page 25 ADDITIONAL INSTRUCTIONS ADDITIONAL INSTRUCTIONS: CALIBRATION PROCEDURE FOR SCALES. SOFTWARE CALIBRATION. Keep a standard weight on the pan.(See below for std. Weights) Press key simultaneously and immediately press key. Wait the scale to calibrate itself and it will display the weight equal to the weight kept on the pan.
  • Page 26 SETUP FUNCTIONS ENTERING SETUP MODE Switch Off the scale. Switch on the machine keeping the key pressed. Do not release this key until the scale displays SEt UP And subsequently displays -FACt- For changing between the menu mentioned above Press key.
  • Page 27 Corporate Office: 301, Punit Indl. Premises, Turbhe Naka, Navi Mumbai - 400 705. Tel.: +91 22-2761 1176 / 77 / 78 / 79 / 80, 2761 8431 Fax: 3245 9901 / 02 / 06 / 18 +91 22-2761 8421 E-mail: sales@contechindia.in / info@@contechindia.in Website: www.contechindia.com...

Table of Contents