Midas DL451 Operator's Manual
Midas DL451 Operator's Manual

Midas DL451 Operator's Manual

Xl8 live performance system modular i/o
Table of Contents

Advertisement

Quick Links

DL451 Modular I/O
Website: www.midasconsoles.com
DL451 Modular I/O - Operator Manual
DOC02-DL451 Issue 1 - April 2007
In line with the company's policy of continual improvement, specifications and function may be
subject to change without notice. This Operator Manual was correct at the time of writing. E&OE.
Operator Manual
Midas,
Klark Teknik Building,
Walter Nash Road,
Kidderminster.
Worcestershire.
DY11 7HJ.
England.
Tel: +44 1562 741515
Fax: +44 1562 745371
Email: info@uk.telex.com
© Telex Communications (UK) Limited

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL451 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Midas DL451

  • Page 1 Tel: +44 1562 741515 Fax: +44 1562 745371 Email: info@uk.telex.com Website: www.midasconsoles.com DL451 Modular I/O - Operator Manual DOC02-DL451 Issue 1 - April 2007 © Telex Communications (UK) Limited In line with the company’s policy of continual improvement, specifications and function may be...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “Dangerous Voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
  • Page 5 We, Telex Communications (UK) Limited of Klark Teknik Building, Walter Nash Road, Kidderminster, Worcestershire, DY11 7HJ, declare that a sample of the following product: Product Type Number Product Description Nominal Voltage(s) Current Freq. DL451 Modular I/O 115V AC 0.5A 50/60Hz 230V AC 0.3A...
  • Page 7 Midas™ or Klark Teknik™ product, as well as other software that we provide for installation on the product. The Midas™ or Klark Teknik™ product will not operate in accordance with its documentation without this software.
  • Page 8 Linux EULA. If you wish to receive a computer-readable copy of the source code for the Linux programs that have been provided with your Midas™ or Klark Teknik™ product, send a check or money order (no cash accepted), your address, and $10.00 to cover the cost of optical media, postage and handling, to:...
  • Page 9 • Any part that is damaged should be properly repaired or replaced. This must be done by a fully trained and authorised service engineer. • Observe all warnings, cautions etc. on any part of the equipment. • Do not remove, hide or deface any warnings or cautions. DL451 Modular I/O Operator Manual...
  • Page 10 • Before connecting up the equipment, check that the mains power supply voltage rating corresponds with the local mains power supply. The rating of the mains power supply voltage is printed on the equipment. • Mount in rack only. DL451 Modular I/O Operator Manual...
  • Page 11 (20Hz to 20kHz), the signal to noise ratio may be degraded. Degradation of up to 60dB at a frequency corresponding to the modulation signal may be experienced under extreme conditions (3V/m, 90% modulation). DL451 Modular I/O Operator Manual...
  • Page 12 To comply with part 15 of the FCC Rules, any special accessories (that is, items that cannot be readily obtained from multiple retail outlets) supplied with this equipment must be used with this equipment; do not use any alternatives as they may not fulfil the RF requirement. DL451 Modular I/O Operator Manual...
  • Page 13: Table Of Contents

    DL452 digital I/O module ....... . 33 DL451 Modular I/O...
  • Page 14 Analogue output module (DL442) ......54 AES/EBU digital I/O module (DL452) ......55 DL451 Modular I/O Operator Manual...
  • Page 15 MIDI and GPIO ........58 Digital system inputs and outputs ......58 DL451 Modular I/O Operator Manual...
  • Page 16 DL451 Modular I/O Operator Manual...
  • Page 17: Introduction

    About this manual Purpose This is the operation manual for the DL451 Modular I/O. It is intended to help get your DL451 Modular I/O installed and in operation as quickly as possible by giving you unpacking, installation, connection, setting up and operating instructions. To help familiarise you with the DL451 Modular I/O there is a description of the front and rear panels, along with easy-to-follow user instructions.
  • Page 18: Intended Readers

    • Chapter 6 - Main Menu Gives details on how to access the main menu and set up the DL451 Modular I/O via the control panel. • Chapter 7 - Operation A more in-depth guide on how to use the DL451 Modular I/O.
  • Page 19: Package Contents/Unpacking

    Packing list The following is a list of the main items contained in the DL451 Modular I/O package: • 1-off DL451 Modular I/O unit. • 1-off DL451 Modular I/O operator manual (this document), part number DOC02-DL451.
  • Page 20 Chapter 1: Introduction DL451 Modular I/O Operator Manual...
  • Page 21: Xl8 Live Performance System Overview

    The standard XL8 system, which provides the full 96 inputs and 51 outputs, comprises: • 1-off XL8-5BCC (flight-cased, five-bay control centre). • 4-off XL8 stage box (DL431). • 5-off XL8 I/O box (DL451). • 10-off XL8 DSP units (DL471). • 2-off XL8 router units (DL461).
  • Page 22 Warranty Three years. Audio quality • Three mic pre amps per input FOH, monitor and broadcast. • Midas EQ (sound quality and ‘feel’). • Four filters. • Midas dynamics. • Four styles (five on outputs). • Midas quality input and output.
  • Page 23: System Hardware

    (1-off) and output (1-off). • DL431 Mic Splitter (4-off): 6U 19” rack unit that provides 24 mic/line inputs. • DL451 Modular I/O (5-off): 3U 19” rack unit that provides a maximum of 24 audio inputs and 24 audio outputs. • DL471 DSP (10-off): 1U 19” rack unit that forms part of the modular DSP engine.
  • Page 24: Network

    - between control centre and router - is either Cat6 or fibre optic. The combination of audio, control, clock and third party Ethernet data in a single network means that the hardware interfaces on a single RJ45 connection. All system connections are duplicated for full dual redundancy. DL451 Modular I/O Operator Manual...
  • Page 25: System Interconnections

    - left and right - are identical (ignoring the DN9331 RAPIDE). Three of the DL451 Modular I/O units are connected to the X and Y sockets on the XL8 Control Centre and the other two are directly connected to both routers.
  • Page 26: Connecting Up The Xl8

    Chapter 2: XL8 Live Performance System Overview Connecting up the XL8 This diagram shows the network interconnections for a typical FOH XL8 system. FOH DL451 Modular I/O - rear RapidE Note: All connections are dual redundant, so the system can operate quite normally using either the X or Y cables.
  • Page 27 Link DSP backbone (cables linking connectors 1-1 and 6-6 are non-standard lengths) DSP unit Mic splitter Router (X and Y) I/O box Main cable Duplicate cable Note: Cable descriptions can be found in “Cable type and function” on page 12. DL451 Modular I/O Operator Manual...
  • Page 28: Cable Type And Function

    Carries standard 100bs Fast Ethernet data. Router Cat5 AES50 audio - bank 0 > Y. Ethercon XLR Ethercon XLR Carries a bi-directional combination of 24 channels of 96KHz audio plus 5Mbs of control Router Mic splitter data. DL451 Modular I/O Operator Manual...
  • Page 29: System Interconnection Checklist

    • In the Ethernet control bank on the X router, connect the 10 sockets to the Ethernet control X socket on DSP units. Repeat for Y router, using the equivalent Y sockets on the DSPs. • DSP/DSP: Connect all of the DSP units together. DL451 Modular I/O Operator Manual...
  • Page 30: Foh And Mon

    Stage 24-channel bi-directional MidasNET Main Duplicate Multiple MidasNET links Main Local I/O units Duplicate 192-channel bi-directional MidasNET trunk link Main Duplicate XL8 Control Centre Figure 2: Typical XL8 Live Performance System FOH and MON set-up DL451 Modular I/O Operator Manual...
  • Page 31: Audio Physical Connections

    • 96-off transformer isolated analogue ‘broadcast’ mic splits (fixed gain). All of the configurable connections are on the five DL451 I/O units, which can be freely located at the FOH or on stage. Three banks of sockets (eight XLRs each) are available for: •...
  • Page 32 432 audio connections can be achieved (subject to other system limits). This gives a maximum XLR count of 720. Figure 3 shows a system configuration containing the extra nine DL451 I/O units, but does not show the redundant duplicated network.
  • Page 33: Mix Matrix

    • Bass EQ filter with choice of four filter types. • Routing via level controls to 48 aux mix buses. • Routing via pan control to left and right master buses. • Routing to mono master bus. • Panpot (SIS™). • Direct output. DL451 Modular I/O Operator Manual...
  • Page 34: Mix Channel Processing

    Each of the three master output buses has: • Six-band PEQ. • Optional 31-band GEQ (replaces PEQ). • Five-mode frequency-conscious compressor with soft clip limiter and external side chain. • Insert point. • Direct input. DL451 Modular I/O Operator Manual...
  • Page 35: Output Channel Processing

    This unit provides rapid adjustments of the graphics with real hardware, and not a mouse and screen. The graphic channel is selected either by the control centre’s SOLO button (solo tracking system (STS)) or by buttons on the RAPIDE itself. DL451 Modular I/O Operator Manual...
  • Page 36: Control Software

    The XL8’s operating system is Linux, which is an open-source, stable, proven operating system (OS). Linux is used in many mission-critical applications worldwide and has allowed Midas’ software engineers to write a ground-up system that contains no ‘hidden’ or unused code. This has resulted in an efficient, compact application, which is quick in operation, quick booting and comparatively easy to debug.
  • Page 37 Resilience to failure (redundancy) Local I/O units Internal bay processor Dual redundant DL451 Modular I/O internal master controller Dual redundant internal router Control data Cat6/optical ‘snake’ Audio data N + 1 redundant Control and spare audio data Router Monitor This diagram gives a...
  • Page 38 Chapter 2: XL8 Live Performance System Overview Local I/O units DL451 Modular I/O Internal bay processor Green interconnections indicate that communications are Internal master healthy controller Internal router units I/O units Router This diagram illustrates an extreme Monitor example of dual...
  • Page 39 Resilience to failure (redundancy) Local I/O units Internal bay DL451 Modular I/O processor Internal master controller Internal router Green interconnections Red interconnections indicate that indicate no communications are communication due healthy to faulty router units I/O units Router Router (healthy)
  • Page 40: Integration Of Third Party Software

    Midas network, and will transfer audio to and from the Midas hardware without any additional interfaces or converters (provided it runs in TDM 96kHz mode). This will be particularly useful as the protocol gains acceptance with recording and playback devices, loudspeaker controllers, audio networking systems, digital amplifiers etc.
  • Page 41: System Documentation

    Control Centre. (this document) DL471 DSP Operator Full user instructions for the DSP. Hard copy, DOC02-DL471 Manual wire-O bound DL451 Modular I/O Full user instructions for the Hard copy, DOC02-DL451 Operator Manual Modular I/O. wire-O bound DL461 Router Operator Full user instructions for the...
  • Page 42 Chapter 2: XL8 Live Performance System Overview DL451 Modular I/O Operator Manual...
  • Page 43: Front Panel

    28. Control panel The control panel is used for setting up the DL451 Modular I/O unit via a main menu. It comprises an LCD panel and four buttons. The LCD panel also displays unit information during operation. Each button illuminates with a blue backlight when pressed.
  • Page 44: Psu Panel

    In the AES50 panel, each X and Y channel has a green ok LED and red error LED. These illuminate to indicate that the communications to these channels is ok or that there is an error. DL451 Modular I/O Operator Manual...
  • Page 45: Rear Panel

    • Ethernet control. • AES50 audio. • Two USB connectors: host and slave. • Three MIDI sockets: in, out and thru. • Two GPIO sockets: in and out. • Mains IEC socket and adjacent on/off switch. DL451 Modular I/O Operator Manual...
  • Page 46: Rear Panel Connections

    Two GPIO 25-way connectors, in and sockets for connection of a laptop PC. out, for control of external devices. Three MIDI (musical instrument digital Mains IEC socket with on/off switch. interface) sockets, in, out and thru for DL451 Modular I/O Operator Manual...
  • Page 47: Dl441 Analogue Input Module

    Green check LED illuminates to indicate when a channel is selected on a console. These are controlled by the console and used as a visual aid to locate specific connectors. Red 48V LED illuminates to indicate 48V phantom voltage is on. DL451 Modular I/O Operator Manual...
  • Page 48: Dl442 Analogue Output Module

    Green check LED illuminates to indicate when a channel is selected on a console. These are controlled by the console and used as a visual aid to locate specific connectors. Red Mute LED illuminates to indicate that channel is muted. DL451 Modular I/O Operator Manual...
  • Page 49: Dl452 Digital I/O Module

    These are controlled by the console and used as a visual aid to locate specific connectors. Red sync LED illuminates to indicate that a valid AES3 connection is present on the digital input. Red Mute LED illuminates to indicate channel is muted. DL451 Modular I/O Operator Manual...
  • Page 50 Chapter 4: Rear Panel DL451 Modular I/O Operator Manual...
  • Page 51: Getting Started

    Switching the unit on and off After you have connected up your DL451 Modular I/O it is ready to be switched on. To do this, switch on the mains on/off switch on the rear of the unit.
  • Page 52: Setting Up

    Chapter 5: Getting Started Setting up Initial setting up of the DL451 Modular I/O involves allocating an ID for it within the XL8 network system environment, see “To set up the unit’s ID” on page 44. Configuration Configure the DL451 Modular I/O unit to suit your operating requirements; see Chapter 6 “Main Menu”...
  • Page 53: Main Menu

    • Option 1 “1 AES clock”: for selecting the method of synchronising the AES50. See page 43. • Option 2 “2 Set ID”: for setting up the DL451 Modular I/O’s network unit ID. See page 44. • Option 3 “3 CBMA Version”: for viewing the DL451 Modular I/O’s CBMA version number.
  • Page 54: Main Menu Flowchart (Options 1 To 4)

    Option 1 Option 2 Option 3 Option 4 Option 5 This option does not appear if there are no digital I/O boards fitted. Go to page 40 for details of option 5. DL451 Modular I/O Operator Manual...
  • Page 55 Pressing the up arrow takes while flashing options any changes. you in the opposite direction are available for to a down arrow press. selection. DL451 Modular I/O Operator Manual...
  • Page 56: Main Menu Flowchart (Option 5)

    3-4, 5-6 and 7-8 This action occurs even if there is no digital board fitted in selected board position Pressing SELECT has no effect if there is no digital board fitted in selected board position DL451 Modular I/O Operator Manual...
  • Page 57 Main menu options F option option Select from OUTPUT and INPUT SRC settings for Ch1&2, 3&4, 5&6 and 7&8 Above options show OUTPUT SRC Ch1&2 selected, as an example DL451 Modular I/O Operator Manual...
  • Page 58: To Enter The Main Menu And Select An Option

    MENU button as many times as necessary until you are back at the default screen. The DL451 Modular I/O will exit the main menu automatically after about 20 seconds of inactivity, that is, if none of the buttons are pressed within that time.
  • Page 59: Option 1 Aes Clock

    Option 1 AES clock Option 1 AES clock This option allows you set up the clock source (as internal or external) of the DL451 Modular I/O for AES synchronisation. To set up the unit’s clock source Enter the main menu and select option 1;...
  • Page 60: Option 2 Set Id

    Chapter 6: Main Menu Option 2 Set ID This option allows you set up the unique ID of the DL451 Modular I/O to distinguish it from any other DL451 Modular I/Os in the XL8 Live Performance System network. Any number from 1 to 10 is available.
  • Page 61: Option 3 Cbma Version

    Option 4 Software Vers. This view only option allows you to view the current host software version that the DL451 Modular I/O unit is running. To view the unit’s current host software version Enter the main menu and select option 4;...
  • Page 62: Option 5 Digital Boards

    Press SELECT to select this option and save the setting. The display will show the “Saving new setting” message and then go back to the “Clock source/From Inputs” display. Use the MENU button to exit. DL451 Modular I/O Operator Manual...
  • Page 63: To Set Up The Src Setting

    The display will show the “Saving new setting” message and then go back to the display of the setting you have just altered, for example, “INPUT SRC Ch3&4/on”. Use the MENU button to exit. DL451 Modular I/O Operator Manual...
  • Page 64: To Set Up The Word Size For The Digital Outputs

    Press SELECT to select this option and save the setting. The display will show the “Saving new setting” message and then go back to the “select bit size/16 bits” display. Use the MENU button to exit. DL451 Modular I/O Operator Manual...
  • Page 65: Operation

    This chapter explains the default display, describes how to replace a module and provides routine service information. There are no operating procedures associated with the DL451 Modular I/O, as it is operated solely from the XL8 Control Centre; please refer to its operator manual (part number DOC02-XL8) for details.
  • Page 66: Replacing A Module

    Chapter 7: Operation Replacing a module The design of the DL451 Modular I/O makes module replacement very easy and straightforward. The unit has rack guides in each of the three module positions so that the modules can slide easily in and out. Each module is held in place by two screws, at the left- and right-hand sides, and a short metal post (or stud) adjacent to each screw facilitates removal.
  • Page 67: Service Information

    The service manual for this equipment is available for purchase. Please contact your local distributor for details. Routine maintenance To help keep your DL451 Modular I/O unit in good working order and to make sure it gives you optimum performance, we recommend that you carry out the following: Monthly •...
  • Page 68: Equipment Disposal

    WEEE legislation. The horizontal bar underneath indicates that the product was placed on the EU market after 13th August 2005. For WEEE disposal, see our website at www.midasconsoles.com for information. DL451 Modular I/O Operator Manual...
  • Page 69: Appendix A Functional Block Diagram

    Appendix A: Functional Block Diagram Analogue input module (DL441) Line/mic board details. ADDRESS REMOTE CONTROL DATA INTERFACE REMOTE STATUS INTERROGATE SYSTEM LOCAL -5 to 40dBu Gain WORD CLOCK MIC/LINE DIGITAL INPUT 1 OF 8 CHANNEL PATHS DIGITAL BACKPLANE SIGNALS DL451 Modular I/O Operator Manual...
  • Page 70: Analogue Output Module (Dl442)

    Appendix A: Functional Block Diagram Analogue output module (DL442) Line out board details. SYSTEM LOCAL WORD CLOCK DIGITAL DIGITAL BACKPLANE SIGNALS ADDRESS REMOTE CONTROL DATA INTERFACE Lo Pass Filter MUTE REMOTE STATUS INTERROGATE LINE 1 OF 8 CHANNEL PATHS DL451 Modular I/O Operator Manual...
  • Page 71: Aes/Ebu Digital I/O Module (Dl452)

    FPGA AUDIO SYSTEMS MUTE REMOTE REMOTE SYNC Input Output CLOCKS STATUS INTERROGATE INTERROGATE STATUS Clocks Clocks 12S Digital Audio 12S Digital Audio Clock Digital Audio Digital Audio Control Transmitter Receiver CPLD CLOCKS CLOCKS AES/EBU AES/EBU DL451 Modular I/O Operator Manual...
  • Page 72 Appendix A: Functional Block Diagram DL451 Modular I/O Operator Manual...
  • Page 73 XL8 XL8 Live Performance System, please refer to the XL8 Control Centre Operator Manual (part number DOC02-XL8). Due to a policy of continual improvement, Midas reserves the right to alter the function or specification at any time without notice.
  • Page 74 Digital system inputs and outputs System connector AES50 (24 channels of bi-directional digital audio) on Ethercon XLR Duplicate connector AES50 (24 channels of bi-directional digital audio) on Ethercon XLR providing dual redundant back up of channels DL451 Modular I/O Operator Manual...
  • Page 75 Thank you for reading through this Operator Manual. We hope you found it useful. Please feel free to send us your comments. Our contact details can be found at the front of this manual. More detailed information on the XL8 Live Performance System can be found in the XL8 Control Centre Operator Manual, part number DOC02-XL8.
  • Page 76 Midas Klark Teknik Building, Walter Nash Road, Kidderminster. Worcestershire. DY11 7HJ. England. Tel: +44 1562 741515, Fax: +44 1562 745371 Email: info@uk.telex.com Website: www.midasconsoles.com...

This manual is also suitable for:

Dl471