Advertisement

CLOUD 9 SMOKER USER GUIDE
030402
THE VENTILATION SPECIALISTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLOUD 9 SMOKER and is the answer not in the manual?

Questions and answers

Summary of Contents for Super Vac CLOUD 9 SMOKER

  • Page 1 CLOUD 9 SMOKER USER GUIDE 030402 THE VENTILATION SPECIALISTS...
  • Page 2 The CLOUD 9 SMOKER User Guide Rev. # 030402 Super Vacuum Manufacturing Co., Inc., P. O. Box 87, Loveland, CO 80539 Phone 1-800-525-5224 / Website: www.supervac.com...
  • Page 3: Table Of Contents

    This manual covers the description, warnings, cautions, operation and maintenance of the Super Vac Cloud 9 Smoker Please take the time to read this manual before operating the smoker. Save this guide for future reference. CONTENTS BREAKAGE OR DAMAGE DURING SHIPMENT....................2 INTRODUCTION .............................3...
  • Page 4: Breakage Or Damage During Shipment

    BREAKAGE OR DAMAGE DURING SHIPMENT The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it correctly. Please read these instructions carefully. Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a description on the freight or express bill describing the damage and the number of pieces.
  • Page 5: Introduction

    INTRODUCTION Congratulations for purchasing the Super Vac Cloud 9 Smoker. We hope it will bring you long hours of satisfaction. Please carefully and completely read the following instructions for the safe operation of the Super Vac Cloud 9 Smoker. WARNING and CAUTION are used throughout this manual to forewarn of possible danger to the users if precautions are not observed.
  • Page 6: Basic Description

    At the heart of the SUPER VAC CLOUD 9 SMOKER is an electronic assembly that keeps the heating block at a stable temperature. This is done by the integration of three electronic fail-safe systems. This design will protect against over and under-heating conditions and component failures.
  • Page 7: Technical Specifications

    Up to 2500 cubic feet per minutes Fluid consumption: 0.33 US gal. per hour at 40 psi (maximum operating pressure) Cloud 9 Smoker fluid type: (use only) Super Vac Oil-based Smoker Fluid (SVOSF) Fluid tank capacity: 0.66 US gal. Gas consumption: 2,13 lbs.
  • Page 8: Setting Up

    SETTING UP WARNING It is recommended that this unit be operated under the supervision of personnel that have read and understood this manual. Never install this unit overhead. The smoker must be operated and stored in an upright position on a stable and level surface. Do not operate closer than six feet (6 ft.) from personnel.
  • Page 9: Gas And Fluid Requirements

    ACC is initiated. Output pressure can be adjusted by mean of the or N regulator. The operating pressure range for the CLOUD 9 SMOKER is 10 to 40 psi.
  • Page 10: Fluid

    Making sure that no other particles are mixed or added to the Super Vac fluid (SVOSF). CAUTION The Super Vac Oil-based Cloud 9 Smoker Fluid produces a pure white non-toxic smoke. Use of this cloud 9 smoker with any other fluid will automatically void the warranty.
  • Page 11: Filling Of The Fluid Tank

    • Turn off the (on/off smoke) switch on the remote timer control (see Fig. A), wait 2 minutes for the ACC and depressurization of the fluid tank. • Now unscrew the red cap located on top of the unit and slowly pour the Super Vac Oil-based Smoker Fluid (SVOSF) until it reaches the inside bottom of the opening.
  • Page 12: Operating Instructions

    Immediately turn off the unit, wait 4 to 5 minutes and retry the unit. If the fail mode reappears, disconnect the unit and contact SUPER VAC.
  • Page 13 Fig. A CLOUD 9 SMOKER Remote Control Timer Timer functions Yellow led indicates Green led indicates smoke time (off) smoke time (on) Smoke output percentage adjustment The period control activates the from 5 to 100% of the period adjustment smoke output length of time indicated by the yellow led.
  • Page 14: Shutdown Procedures

    Fig. A CLOUD 9 SMOKER Remote Control Timers CAUTION Never disconnect or power off while your cloud 9 smoker is producing smoke. Read the following shutdown procedures. The 100% duty cycle is continuous with specified line voltage and will degrade with line voltage loss. Reducing the operating pressure can compensate this.
  • Page 15: Warranty

    WARRANTY LIMITED WARRANTY FIVE YEARS Super Vacuum Manufacturing Company warrants that the equipment is free from defects in materials and workmanship when used and operated for a period of five years. The responsibility of Super Vacuum Manufacturing Company under this limited warranty is limited to the repair and replacement of any parts which are found defective and which are returned to Super Vacuum Manufacturing Company at 3842 Redman Dr, Fort Collins, CO 80524 with transportation charges prepaid (C.O.D.
  • Page 16: Contact Information

    CONTACT INFORMATION Fire-End & Croker Corp - 7 Westchester Plaza - Elmsford, NY 10523 - 800-759-3473 Order on-line at fire-end.com THE VENTILATION SPECIALISTS...

Table of Contents