We reserve the right to revise this document or make changes in the specifications of the product described therein at any time without notice and without obligation to notify any person of such revision or change. Colormetrics P3100 www.colormetric.net...
Dispose used batteries according to the manufacture’s instructions. Do not remove the cover, and ensure no user serviceable components are inside. Take the unit to the service center for service and repair. www.colormetric.net Colormetrics P3100...
1D/2D barcode scanner 8” pole customer display RFID (13,56 MHz) 15” pole customer display iButton UPS battery Smart card reader Fingerprint reader Addimat waiter key *Note: Nearly all modules are also available as 2-in-1 or 3-in-1 solution. www.colormetric.net Colormetrics P3100...
Page 12
+5V/+12V DSR# Green Blue DTR# I2C DATA RST# HSYNC CTS# VSYNC I2C CLK 4. 2-Layer USB 3.0+2.0 connector Definition Definition 5. 2-Layer USB 2.0 connector Definition Definition 6. PS/2 K/B port Definition Definition KB_DAT MS_CLK MS_DAT KB_CLK Colormetrics P3100 www.colormetric.net...
Page 13
Example DOS COMMAND for Cash Drawer: 1. Create the file: TEST.TXT 12. Powered 24V USB 2. Input below contents in TEST.TXT Definition CONTEXT-"000.0” MODE COM6:300 3. Run COMMAND under DOS mode USB D- COPY TEST.TXT COM 6 USB D+ +24V +24V www.colormetric.net Colormetrics P3100...
2. Install HDD kit with two screws 3. Plug e-SATA cable into the position shown in the picture 3 5-6 8” 2nd Monitor 1. Remove the cover 2. Plug cable into the 1*4 pin connector 3. Install 8” 2nd Monitor with two screws www.colormetric.net Colormetrics P3100...
2. Assemble the adapter bracket with two screws 3. Assemble the back cover the stand with two screws Note: The adapter bracket of P3100 is only for P3100 standard adapter (Model name: FSP150, 150W). Please don’t assemble other type adapter into the stand. Colormetrics P3100...
5-8 1D / 2D / i-Button with RFID module 1. Cable installation. For I-Button / RFID /1D/2D barcode scanner, please connect the cable as shown in fi gure 2. Fix the screws as shown in below fi gure. www.colormetric.net Colormetrics P3100...
Page 24
10. Select “Create a eGalaxTouch Utility shortcut on desktop”, Click “Next”. Colormetrics P3100 www.colormetric.net...
Page 25
11. Would you do 4 point calibration now? Click “Yes”. 12. Do 4 points aligrment to match display 13. Calibration utility www.colormetric.net Colormetrics P3100...
1. The utility program will detect the connected reader. If detected, all the input text boxes will be enabled. 2. If the reader has not been connected to PC yet, please connect the reader and then click Refresh to get connected. Colormetrics P3100 www.colormetric.net...
Page 27
3. Error Message: Indicates which track number cause the error. 4. Delimiter: Indicates the swipe result. 5. ISO: Define start and end sentinel character. 6. Decode Mode: Determines the way of outputting the three tracks data. www.colormetric.net Colormetrics P3100...
Page 28
• TK3: For the prefix string, it is appended in the front of the start sentinel of track 3. For the suffix, it is appended in the end of the end sentinel of track 3. The max data length of the prefix and suffix for the TK1 can be up to 127. Colormetrics P3100 www.colormetric.net...
Page 29
If the specified track data is not decoded, even MSR data string contains other track data, it will still not to be output. 3. Disable: If selected, the data of specified track will not be packaged in the MSR data string. No matter it is decoded or not. www.colormetric.net Colormetrics P3100...
Page 30
To load pre-saved settings, click Open, specify the settings file, and then click OK to load into program. Restore MSR Reader Settings To load restore settings of connected MSR reader, click Restore ES2: End sentinel for track. Colormetrics P3100 www.colormetric.net...
Page 31
Software folder of CD. 3 . Follow the wizard to complete the installation. Launching Program Below steps guide you how to load the Utility program. 1. From Start/Programs, click MagSwipe folder 2. Click MagSwipe Configuration Utility to launch the program. www.colormetric.net Colormetrics P3100...
Page 32
Configuration Select Reader Interface The reader to be configured should be connected. Select the corresponding connected reader interface and click the Continue button Colormetrics P3100 www.colormetric.net...
Page 33
After selecting the appropriate interface for the reader, select one of the Home Menu Page buttons to proceed with the Magnetic Stripe Reader (MSR) configuration process. The „Basic Reader Settings“ group defines the basic operating parameters and data output format of the reader. www.colormetric.net Colormetrics P3100...
Page 34
Load From File The configuration data can be loaded into the configuration utility from a file that has been previ- ously saved. Select this command, start a „File Open“ dialog, which allows selection of the file. Colormetrics P3100 www.colormetric.net...
Page 35
The settings take effect immediately. The default parameters affect all reader configurations settings. Close Close this dialog and return to the Home Menu Page. General Settings This group of configuration settings defines the basic operating parameters of the reader. www.colormetric.net Colormetrics P3100...
Page 36
In the single swipe direction selections, the card can only be swiped in one specified direction to read the card. The default setting will decoding card data with the card swiped in either the forward or the reverse direction. Colormetrics P3100 www.colormetric.net...
Page 37
If the host system is not capable of receiving characters as fast as the reader can transmit, setting an appropriate inter-character delay will keep the reader from overrunning the host input buffer. The default is 2ms. www.colormetric.net Colormetrics P3100...
Page 38
These can be special characters for identifying a specific track. End Sentinel The magnetic stripe End Sentinel character can be added to the end of a magnetic stripe data string. This character simulates the end of character for track1, track2 or track3. This default is ‚?‘ Colormetrics P3100 www.colormetric.net...
Page 39
Track.(All tracks written on the card will be read). Track Separator Selection This option allows the user to select the character to be used to separate data decoded by a multiple-track reader. The default value is CR www.colormetric.net Colormetrics P3100...
Page 40
This option let reader to send out [SS]E[ES] if failed to read or missing data on a selected track.The default is off. The error output for track 1 is „%E?“. The error output for track 2 is „;E?“. The error output for track 3 is „+E?“. Colormetrics P3100 www.colormetric.net...
Page 41
Function Key Output The function key output be used to support the special key to delay card data output. USB HID KB Polling Interview The user can input the number between 1 to 255 for the delay of output. www.colormetric.net Colormetrics P3100...
Page 42
Check Current Reader Setting After you connect the device, the current reader configuration can be displayed by selecting this button. The configuration data of the connected reader will be displayed like in the example: Colormetrics P3100 www.colormetric.net...
Page 52
Step 19 Put your finger on fingerprint reader and follow the direction to enroller your fingerprint it need scan your fingerprint 4 times Step 20 after enroller finish it will popup a dialog box Colormetrics P3100 www.colormetric.net...
1.1 Check the Device Manager to verify the status of RFID reader. Computer Management -> Device Manager -> Other devices (The device will show a question mark if the installation is not done properly.) 1.2 Double-click to Update driver. www.colormetric.net Colormetrics P3100...
Page 54
1.3 Select “Browse my computer for driver software.” 1.4 Click Browse to select file called HFF320U \Driver\FTD\x64 And click Next. 1.5 Install the driver Colormetrics P3100 www.colormetric.net...
Page 55
1.6 Install complete and then click “close” 1.7 Restart the computer www.colormetric.net Colormetrics P3100...
Page 56
2.1 Double-click the file to launch it. 2.1 Double-click to install. 2.2 Select “I have read and accept the license terms. And click Install.. 2.2 Select “I have read and accept the license terms”. And click the Install Button. Colormetrics P3100 www.colormetric.net 55 | 79...
Page 57
The demonstration software can run either from CD or a copy on hard drive. The GUI of software is shown in below picture and ready to use. 3.2 Following steps, as shown in below picture, demonstration a simple usage in reading UID of ISO14443A card for quick understanding. www.colormetric.net Colormetrics P3100...
- Follow the wizard to complete the installation. Launching Program Below steps guide you how to load the Utility program. - From Start/Programs, click HIDMSR-20 Utility folder - Click MagStripe Card Reader Configuration Utility to launch the program. www.colormetric.net Colormetrics P3100...
Page 60
• The utility program will detect the connected reader. If detected, all the input text boxes • If the reader has not been connected to PC yet, please connect the reader and then click Refresh to get connected. Configuration Below is the main window of i-Button Utility program. Colormetrics P3100 www.colormetric.net...
Page 61
To load pre-saved settings, click Open, specify the settings file, and then click OK to load into program. Restore MSR Reader Settings To load restore settings of connected MSR reader, click Restore ES2: End sentinel for track. www.colormetric.net Colormetrics P3100...
Page 62
Below steps guide you how to install the Utility program. • Insert the setup CD. • Run the Colormetrics i-Button Utility.exe setup file that is located in the Software folder of CD. • Follow the wizard to complete the installation.
Page 64
• The utility program will detect the connected reader. If detected, all the input text boxes will be enabled. • If the reader has not been connected to PC yet, please connect the reader and then click Refresh to get connected. Colormetrics P3100 www.colormetric.net...
Page 65
Configuration Below is the main window of i-Button Utility program. For the settings, there are: • Prefix/Suffix: Defines the data string which you would like to append in front or end of the i-Button key string. www.colormetric.net Colormetrics P3100...
Page 66
• Length : i-Button ID length request from 0~16 • Output order : 4 formats could be select at Attach /Remove i-Button ID. iButton 64- Bit Registration Number: 8-Bit CRC + 48-Bit ID + 8-Bit FC DEMO SETUP&OUTPUT OUTPUT DATA : a!ab00000003bdfa01? b!ab00000003bdfa01? Colormetrics P3100 www.colormetric.net...
Page 70
7. Run the testing program – EZ100test. 8. Conferm that SCR can be detected by the testing program, the Start Testing Colormetrics P3100 www.colormetric.net...
Page 71
9. Follow dialog boxes displayed to remove and insert card. 10. After finishing the testing, the dialog box will show “oK”. www.colormetric.net Colormetrics P3100...
OS, these items are automatically updated whenever you make changes to the Windows Date and Time Properties utility. WARNING! Setting the wrong values in the sections below may cause the system to malfunction. Make sure that the settings made are compatible with the hardware. Colormetrics P3100 www.colormetric.net...
7-1 Advanced Use the Advanced menu to confi gure the CPU and peripheral devices through the following sub-menus: 7-1-1 Boot Confi guration Use the Boot Confi guration menu to select power-on state for Numlock www.colormetric.net Colormetrics P3100...
Page 74
Use the Audio Confi guration menu to read Audio confi guration information and confi gure the Audio settings 7-1-3 Video Confi guration Use the Video Confi guration menu to read Video confi guration information and confi gure the Video settings Colormetrics P3100 www.colormetric.net...
Page 75
7-1-4 SATA Confi guration Use the SATA Confi guration menu to read SATA confi guration information and confi gure the SATA settings www.colormetric.net Colormetrics P3100...
This item allows you to select off, 5V or 12V powered COM COM4/6 Cash Drawer This item allows you to select 12V or 24V cash drawer port voltage output LVDS Firmware update This item allows you to enable or disable LVDS Firmware update www.colormetric.net Colormetrics P3100...
Use the Boot menu to select type to Dual type, Legacy type or UEFI type. 7-5 Save & Exit Use the Save & Exit menu to load default BIOS values, optimal failsafe values and to save confi guration changes. Colormetrics P3100 www.colormetric.net...
Page 80
3. What types of cleaners are acceptable? • Water • Vinegar (mixed with water) • Isopropyl Alcohol NOTICE: The following cleaners are unacceptable: • Acetone • Ethyl alcohol • Ethyl acid • Ammonia • Methyl chloride Colormetrics P3100 www.colormetric.net...
Page 81
(WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive. www.colormetric.net Colormetrics P3100...