Summary of Contents for Roof Tech APEX

  • Page 1 RT-APEX installation guide ------2019JUL31 ver.1---- ROOF TECH INC. RT-APEX INSTALLATION GUIDE...
  • Page 2 APEX Base installation Y0: 3/16” from upper shingle Y1: 4 1/8” from Y0 “R” logo left top indicates the Ridge side Y1-Y: PV Width+1 1/16” (Landscape) when installing the base. Y1-Y: PV Length + 1 1/16” (Portrait) 5 Screws 2 Screws...
  • Page 3 APEX Clamp location End Clamp Middle Clamp Note: To fix the modules on the ridge side. The End clamp must be removed and rotated 180 degree also switch the M10 hole. *Bottom clamp stay same direction ONLY End Clamp need to be...
  • Page 4 APEX Splice location End Splice Middle Splice Note; End Splice must be untighten and twist 180 degree to fix panels on ridge side. *Bottom clamp stay same direction ONLY End Splice need to be switched...
  • Page 5 APEX First row installation Important Step for a Smooth Skirt set up. First row alignment Use strings to align the first row, and set the bottom side socket head cap screw. *Place End clamp or End Splice to the base.
  • Page 6 APEX SKIRT & First Row Installation RT-APEX End Clamp ・32-40 mm frame height ・Universal End clamp ・up to 1 9/32” leveling ・Integrated cable holder tray Skirt installation steps At End clamp location Slide in skirt to End clamp Place skirt all the way in...
  • Page 7 APEX SKIRT & First Row Installation RT-APEX End Splice ・32-40 mm frame height ・Universal End clamp ・up to 1 9/32” leveling ・Integrated cable holder tray Skirt & Splice installation note End Splice clamp shall be set with PV panels at the same time,.
  • Page 8 APEX Second & Middle Row Installation First row installation RT-APEX Middle Clamp ・32-40 mm frame height ・Universal End clamp ・up to 1 9/32” leveling ・Integrated cable holder tray Middle clamp installation IMPORTANT!! Set the middle clamp flush with the Torque the middle clamp PV Panel frame.