Digital Thermometer
User Manual
INTENDED USE
The Easy@Home Digital Thermometer EMT-021 is intended for measuring and
monitoring human body temperature. It is suitable for both hospital and home use.
FEATURES
1. Large LCD displays the measured temperature.
2. Memory function shows the last measured temperature on the LCD display.
3. A "Bi Bi Bi" alarm will sound three times in a row for 10 times to indicate a high
temperature, for a total of 30 beeps.
4. Self-test and power automatic shut-off.
5. Quick temperature response and high accuracy (±0.2˚F /±0.1°C).
6. Compares to mercury thermometer minus the problems of both mercury
pollution and possible broken glass.
SPECIFICATIONS
Product name
Easy@Home Digital Thermometer
Applied models
EMT-021
Measure time
25 seconds on average ( Oral Measurement)
Measurement
89.6-109.2˚F (32.0-42.9°C)
range
Low ambient
Temperature<89.6˚F (32.0˚C) display: Lo˚F (Lo˚C)
temperature
display
High ambient
temperature
Temperature>109.2˚F (42.9˚C) display: Hi˚F (Hi˚C)
display
Accuracy
±0.2˚F 95.0-102.2˚F (±0.1℃ 35.0-39.0℃)
Resolution
0.1˚F or 0.1°C
Sensor type
Thermistor
Display type
Memory
Service life
Alarm
Working
environment
EMT-021
Storage
environment
Battery type
Battery life
Power
consumption
Applied
part type
IP classification
Mode of
operation
HOW TO USE
1.
Press On/Off button then the LCD will display 188.8˚F (188.8˚C) for 2 seconds,
a fullscreen display is as below:
Then it will show the last measurement. Wait until ˚F or ˚C flashes, then start
measuring.
If the environmental or ambient temperature temperature is higher than
2.
109.2˚F (42.9˚C), LCD will display Hi˚F (Hi˚C). If lower than 89.6˚F(32.0°C), it
will display Lo˚F (Lo˚C).After turning on the thermometer, it will display below
Liquid Crystal Display
The last measured temperature is shown on LCD Display
Estimated 5 years under normal operation and storage
A "Bi Bi Bi" alarm will sound a total of ten times indicating
the completion of the temperature in the normal range.
A "Bi Bi Bi" alarm will sound three times in a row for 10
times to indicate a high temperature, for a total of 30 beeps.
Temperature: 41~104˚F (5~40°C)
Humidity: 15% to 85% RH
86 Kpa to 106 Kpa
Temperature: -4~131˚F (-20~55°C)
Humidity: ≤85%RH
86 Kpa to 106 Kpa
Button type zinc-manganese dioxide alkaline batteries
(1.5V LR41)
Approx.100 hours for continuous operation.
Or approx.18 months if used 10 minutes daily.
About 0.15 MW
Type BF applied part
IP22 (IP22: The first number 2: Protected against access to
hazardous parts with a finger, and the jointed test finger of
12 mm , 80 mm length, shall have adequate clearance
from hazardous parts. And protected against solid foreign
objects of 12.5 mm
and greater. The second number:
Protected against vertically falling water drops when
enclosure titled up to 15º. Vertically falling drops shall have
no harmful effects when the enclosure is titled at any angle
up to 15 º on either side of the vertical.
Continuous operation
Need help?
Do you have a question about the EMT-021 and is the answer not in the manual?
Questions and answers