Download Print this page

Burlington C24 Manual

Close coupled cistern tank with back and bottom entry water supply with lever flush

Advertisement

Quick Links

Parts supplied:
Inlet Valve
Flush Valve
1x
1x
1: Flush Valve installation
Bolt
Flush Cone
Plug
1x
2x
Plastic
Washer
Lever
Cone Washer
1x
1x
Burlington 510mm close coupled cistern tank
with back and bottom entry water supply with lever flush
Burlington Extended depth 510mm close coupled cistern tank
with back and bottom entry water supply with lever flush
● Please read these instructions carefully to avoid damage
to the valves, and to ensure correct installation.
Fixing Nut
● Do not use bleach or bleach based cleaning products in
the cistern, as these will cause damage to the seals.
1x
1x
We cannot be held responsible or liable for any failure
which results from the use of bleach based products.
● Water temperature range +2C to +45C.
● Water pressure 0.2 to 8 bar.
Flush Cone
1x
1x
1 - 5
C24
C30
C

Advertisement

loading
Need help?

Need help?

Do you have a question about the C24 and is the answer not in the manual?

Questions and answers

Summary of Contents for Burlington C24

  • Page 1 Burlington 510mm close coupled cistern tank with back and bottom entry water supply with lever flush Burlington Extended depth 510mm close coupled cistern tank with back and bottom entry water supply with lever flush Parts supplied: ● Please read these instructions carefully to avoid damage to the valves, and to ensure correct installation.
  • Page 2 Half Flush Adjustor : should be set at 1.5 mark Half Flush Adjustor : should be set at 1.5 mark. C30 Burlington Extended depth 510mm close coupled cistern tank Half Flush Float : should be set on the 2 mark Half Flush Float : should be set on the 2.5 mark...
  • Page 3 1: Inlet Valve adjustment settings and Installation 2: Filter cleaning (Please clean periodically) Filter Inlet pipe Fixing nut Filter Close the water supply, and take off the Screw down the fixing nut, and take off the water Clean by rinsing the filter. Reinstall the inlet valve.
  • Page 4 Close Coupled Cistern & Flush Level Installation 1: Install Close Coupled Cistern To Pan * Please ensure the flush cone is in position before installation. 2: Install Lever Insert the box and tighten the nut. * Raise the lever so that it fits into the flush box in the correct position.
  • Page 5 Low Level Cistern Installation Note: Please carefully check for leaks after installation. Please use two white bolts to block the two fixing holes on the bottom of cistern, cut the bolts to suitable length if necessary. 5 - 5...

This manual is also suitable for:

C30