ABI-EV1012S00
Twisted Pair Broadband
Distribution Amplifier with 2 RF
inputs and IR-bus
Quick Start Guide
1
Package Contents
DIN rail mountable Broadband Amplifier module
Quick Start Guide
3 Termination plugs
Power jumper cord ABI-PS1001SPC
2
Tools
Level tester ABI-TT1003S12
Spanner 11mm
Flat screw driver max. 5mm x 0.6mm
3
Introduction
The ABI-EV1012S00 is a Broadband Amplifier with two coaxial
inputs (one for CATV signal or antenna, and the other for the
connection of a Broadband modulator)
The unit has 4 independent RJ45 (Twisted Pair) outputs on the
front.
A range of Twisted Pair to Coax adapters (with or without
adjustment, filters, IR...) is available for installation at the receiver
end (i.e. ABI-AC1001S00*).
It is possible to connect a Radio by using a Radio adapter (ABI-
AC1004S00) or an adaptor without a filter.
4
Connectors
RF IN 1
Input to CATV signa l
or Antenna
Grounding wire
IR-bus
P1
Power level a djustment
ABI-AC1007S00
5
Power
Load ratio for this module = 0,5.
Maximum allowed load ratio (sum of the load ratios for all modules) for
power supply ABI-PS1001S11 = 4.
English
110406_ABI-EV1012_QSG_ML.doc
RF IN 2
Input to
RF modula tor output
POWER
IR-bus
P2
P3
P4
Outputs to 4 indepent
TV S ets
RF IN 1 Power Adjustment
Connection for
IR Detector
6
Installation
Power Off the central ABI-PS1001S11 Power Supply by means of the
Circuit Breaker installed in the 'Comm Center Cabinet', or by
removing the mains power cord from the Power Supply.
1.
Make sure the shielding of the Network Interface Unit (NIU)
or CATV transition point is properly connected to the
protective ground.
2.
Open the 'Comm Center Cabinet'
3.
Click the ABI-EV1012S00 unit on the metal DIN-rail,
adjacent to the ABI-EV1017S00 modulator (left or right side)
for IR-bus functionality.
4.
The ABI-EV1012S00 is supplied with a grounding wire,
connected to the input F-connector.
This wire (1) must be connected to the protective ground of
the installation.
The following system devices also need to be connected to
the protective ground: The DIN-Rail frame (2) and the Power
supply (3)
1
2
5.
Provide power to the module using the included power
jumper cord ABI-PS1001SPC. Please consult the manual of
the power supply for more information concerning the
installation of the power supply.
6.
Connect a coax cable from the CATV connection point (NIU)
or the CATV transition point to the coax connector on the top
of the unit.
7.
Connect a coax cable (F-F patch cord) from the RF output of
the ABI-EV1017S00 modulator to the coax connector (RF IN
2) on top of the ABI-EV1012S00.
Tighten the screws of the connector, using the spanner
Failing to follow the instructions (1) to (7) in the specified order
may lead to permanent damage of the ABI-EV1012 amplifier
When it is impossible to connect the DIN rails ,frame or CATV
transition point to ground, make sure they are at least at the same
electrical level (connected to each other).
Please also note our recommendation regarding overvoltage at
the end of this manual
Page 5
ENGLISH
DIN-Rail Frame
EV1002
ABI-PS1001SPC
DC1015
Power
Supply
PE1002
3
4
.
abitana
N.V.
S.A.

Advertisement

loading

Summary of Contents for Abitana ABI-EV1012S00

  • Page 1 DIN-Rail Frame Introduction EV1002 The ABI-EV1012S00 is a Broadband Amplifier with two coaxial inputs (one for CATV signal or antenna, and the other for the connection of a Broadband modulator) The unit has 4 independent RJ45 (Twisted Pair) outputs on the ABI-PS1001SPC front.
  • Page 2 For IR functionality, the ABI-AC1007S00 Balun is required DC1015 PE1002 Additional, and more detailed information concerning this product can DIN-Rail be found on the website: www.abitana.com . Frame Use the following table to write down information about the amplifier and the connections. Power...